Setting up umbrella H 1V on a digital tire
Zont can be connected to boilers in two ways. relay and a digital tire. Both options will ensure remote control and autonomous operation of the boiler in selected modes and on schedule.
Relay control
In relay control, the specified temperature is maintained by periodic turning on and off the boiler and is controlled by the temperature sensor included in the Zont supply kit. In this version, Zont is connected directly to the boiler, the adapter for connection is not needed.
Relay control of the boiler is possible if the boiler has a way out to connect a room thermostat (almost all modern electric and gas boilers).
Digital control
When managing the digital tire, the power of the boiler is adjusted smoothly without frequent complete shutdowns. This control method allows you to calculate the optimum temperature of the coolant to maintain a given heating mode and additionally gives wider possibilities:
- Smooth control control of the boiler (burner modulation)
- DIA remote control (if the boiler controls the hot water)
- Deciphering error codes and boiler accidents.
Attention! Digital control is possible if the boiler has a digital tire of the OpenTherm, E-Bus, Ariston or Navien and it is compatible with Zont!
You can check the compatibility and possible ways to manage a specific brand of the boiler on the boilers compatibility page with Zont.
In this version, a digital tire adapter, a digital tire fee or a built-in zont protocol (a built-in protocol is not in all devices; it is in the Zont H-1 Navien, Zont H2000) is required. Plates are used only to connect Zont Climatic regulators. For other devices, adapters are used.
Opentherm, E-Bus/Ariston and Navien digital tires are available in the catalog of the online store TVP-Electro.ru. Adapters of the types of “DIN” and “ECO” differ only in the case and the method of fastening, in terms of functionality they are identical and are equally suitable for working with thermostats and controllers of Zont.
Attention! E-Bus/Ariston protocols are based on one device (this can be an adapter, board or built-in protocol). At the same time, in one device you can use only one of these protocols-either E-Bus or Ariston.
Individual setting of operating modes
Comfortable temperature for each has its own. Some love tropical heat, others believe that 20–22 degrees are more than enough. We have provided several heating modes of the house so that you can choose the right currently. In addition, you can easily make a weekly schedule of the heating boiler for the most optimal consumption of electricity or gas.
The characteristics of the temperature conditions
Economy | Why warm the house when everything is at work? Use this mode and save up to 15% of energy daily, setting the minimum temperature to maintain heat in the room (for example, 15 degrees) |
Comfort | Set the temperature comfortable for yourself and use this mode when you are at home (when the temperature decreases by a couple of degrees, the boiler will turn on to heating to the specified value) |
Anti.commercial | If in winter you move to a city apartment, set this mode and do not worry about the heating system of the house. it is under reliable protection. |
Schedule | Make a weekly heating schedule of the house and every day in it will be comfortable and warm (you can set the minimum temperature during the hours of your absence in the room, and also set to warm up to a comfortable temperature). |
Simple installation that does not require special skills
Zont H-1 is easily connected to an electric or gas boiler instead of a room thermostat. A SIM card of any operator providing a stable technique is inserted into it and is supplied with a supply voltage. You need to send SMS from the owner’s phone and “introduce” the device to the SIM card number.
Technical characteristics of the Zont H-1V module | |
Supply voltage | 10-28v |
The maximum current consumed | 1000 mA |
The number of analog entrances | one |
Output dry contact (closing/opening) | one |
Type of connected wired thermals | DS18S20, DS18B20 |
Type of connected radiopomotors | Ml-740, ml-711, ml-719 |
The total number of simultaneously connected thermal attires | 10 pieces. |
The maximum permissible loop length with thermal sites | 100 m |
Maximum current through relay contacts | 1000 mA |
The maximum voltage of the switched relay contacts | ~ 120 V, = 24 V |
Voice Interais | there is |
Web Inte Web | there is |
1-Wire Inte Wee | there is |
The temperature range of work | from.30 to 55 ° C |
Frequency ranges GSM modem | 800, 900, 1800, 1900 mhz |
Data transmission channel | GPRS |
GSM Antenna | External |
Internal energy.dependent memory | there is |
Built.in backup battery | Li-Ion / 1000 man (option) |
Open exit time | no more than 50 seconds |
The average service life | 7 years |
dimensions | 77 x 86 x 33 mm |
Mass, no more | 0.200 kg |
Building material | Plastic ABC |
Technical documentation for the Zont H-1V module | |
GSM-Climate (Zont H-1V) (PDF, 1.1MB) | |
GSM-Wi-Fi-Climate connection diagram to Ewan Electric Coals (PDF, 0.4MB) | |
Connection diagram Zont-H1-GSM-Wi-Fi-Climate to Evan Expert (PDF, 1MB) | |
Instructions for connecting GSM-Wi-Fi Climate to Evan Universal (PDF, 0.1MB) |
What boilers can the thermostat zont be installed on?
Zont, for its main purpose, a simple indoor thermostat, but only made on a hardware platform using GSM/GPRS modem and web technology. The principle of its operation and the method of connecting to any gas or electric boiler is exactly the same as that of ordinary thermostats. It connects to the connector for the indoor regulator and controls the boiler, maintaining the given temperature according to the testimony of its temperature sensor. To do this, the thermostat turns on or off the boiler, closing the contacts of its output relay.
Thus, if your boiler provides for the possibility of managing commands from indoor thermostat, then Zont thermostat can be used, in particular, the following manufacturers are supported: Evan, Nibe, Protherm, Vaillat, Baxi, Ariston, Beretta, Bosch, Buderus, Viessmann, Dakon, Dakon Navien, Thermona, Electrolux, Rusnit and many others.
Select your region from the list
Moscow Nizhny Novgorod St. Petersburg Arkhangelsk Vladimir Yekaterinburg Kazan Kirov Krasnodar Krasnoyarsk Miass Novosibirsk Permian Samara Syktyvkar Tyumen Ufa Chelyabinsk Yaroslavl
Arhangelsk region Vologda Region Kalina region Leningrad region Murmansk region Novgorod region Pskov region Republic of Karelia Komi Republic
Belgorod region Bryansk region Vladimir region Voronezh region Ivanovo region Kaluga region Kostroma region Kursk region Lipetsk region Moscow and the region Oryol Region Ryazan Oblast Smolensk region Tambov Region Tver region Tula region Yaroslavskaya oblast
Kirov region Nizhny Novgorod Region Orenburg region Penza region Perm Territory Republic of Bashkortostan Mari El Republic The Republic of Mordovia Republic of Tatarstan Republic of Udmurtia Chuvash Republic Samara Region Saratov region Ulyanovsk region
Adygea Astrakhan region Volgograd region Krasnodar region Republic of Kalmykia Republic of Crimea Rostov region
Karachay-Cherkess Republic The Republic of Dagestan Republic of Kabardino-Balkaria Republic of North Ossetia Stavropol region Chechen Republic
Altai region Zabaykalsky Krai Irkutsk region Kemerovo region Krasnoyarsk region Novosibirsk region Omsk region Altai Republic The Republic of Buryatia The Republic of Khakassia Tomsk region Chita region

Amurskaya Oblast Kamchatka Krai Magadan Region Primorsky Krai The Republic of Sakha (Yakutia) Sakhalin region Khabarovsk region
Connection of the Zont thermostat to the boiler via digital tire
- Energy savings during the work of the boiler according to the schedule;
- Energy savings due to the effective use of a modulation burner;
- Increasing the resource of the boiler;
- Effective remote control of the boiler;
- Effective remote service of the boiler.
The thermostat, when connecting through the E-BUS integration, controls the power of the boiler due to the periodic correction of the burner power and ensures the control of the parameters of its operation and the technical condition. In the event of a malfunction (accident) of the boiler, error code and its decoding are transmitted by the thermostat for display in the Web Service.
The following data are necessary for the warranty:
- Unique factory product number;
- The date of shipment from the warehouse;
- Correctly completed information about the dilere and information about the organization of commissioning;
- Location of equipment and f.And.About the owner.
Conditions for the fulfillment of warranty obligations:
- Warranty claims are accepted only if there is a correctly and clearly filled warranty coupon indicating the factory number of the product, the date of sale and commissioning, with the same seals of the company-sales company that commissioned the commissioning.
- The guarantee does not apply to damage that arose as a result of improper use, incorrect installation or commissioning by the buyer or third party, natural wear, incorrect or careless circulation, the use of unsuitable equipment (especially with improper choice and improper commissioning of the burner), the use of unusual fuel and chemicals or electrochemical and electrical influences, if they do not take place through our fault, but also due to non.compliance with the instructions set forth in the guidelines for the installation of operation and maintenance, as well as inappropriate changes and repair work made by the buyer either a third party, and the impact of foreign production components. for example, blocks of control of boiler circuits of other companies).
- Our guarantee for tanning water heaters implies that the water undergoing heating has the quality of drinking water, and the available installations for the preparation of water work impeccably. We strongly emphasize that warranty obligations do not apply to those cases when rapidly intelligent details, such as burner nozzles, nozzles of the burner to reduce emission, fuses, seals, combustion of the combustion chamber or contacting the flame of the ignition and control device, fail as a result of natural wear. Our warranty obligations do not extend further to damage that occurred due to air pollution due to abundant dust deposition, due to aggressive exposure to vapors, oxygen corrosion (especially when using plastic pipes with diffusion permeability in systems with heating panels in the floor of the room), installation in unsuitable rooms (for example, in laundry or workshops) or when continuing to use the defect.

The following data are necessary for the warranty:
- Unique factory product number;
- The date of shipment from the warehouse;
- Correctly completed information about the dilere and information about the organization of commissioning;
- Location of equipment and f.And.About the owner.
Conditions for the fulfillment of warranty obligations:
- Warranty claims are accepted only if there is a correctly and clearly filled warranty coupon indicating the factory number of the product, the date of sale and commissioning, with the same seals of the company-sales company that commissioned the commissioning.
- The guarantee does not apply to damage that arose as a result of improper use, incorrect installation or commissioning by the buyer or third party, natural wear, incorrect or careless circulation, the use of unsuitable equipment (especially with improper choice and improper commissioning of the burner), the use of unusual fuel and chemicals or electrochemical and electrical influences, if they do not take place through our fault, but also due to non.compliance with the instructions set forth in the guidelines for the installation of operation and maintenance, as well as inappropriate changes and repair work made by the buyer either a third party, and the impact of foreign production components. for example, blocks of control of boiler circuits of other companies).
- Our guarantee for tanning water heaters implies that the water undergoing heating has the quality of drinking water, and the available installations for the preparation of water work impeccably. We strongly emphasize that warranty obligations do not apply to those cases when rapidly intelligent details, such as burner nozzles, nozzles of the burner to reduce emission, fuses, seals, combustion of the combustion chamber or contacting the flame of the ignition and control device, fail as a result of natural wear. Our warranty obligations do not extend further to damage that occurred due to air pollution due to abundant dust deposition, due to aggressive exposure to vapors, oxygen corrosion (especially when using plastic pipes with diffusion permeability in systems with heating panels in the floor of the room), installation in unsuitable rooms (for example, in laundry or workshops) or when continuing to use the defect.
Select your region from the list
Moscow Nizhny Novgorod St. Petersburg Arkhangelsk Vladimir Yekaterinburg Kazan Kirov Krasnodar Krasnoyarsk Miass Novosibirsk Permian Samara Syktyvkar Tyumen Ufa Chelyabinsk Yaroslavl
Arhangelsk region Vologda Region Kalina region Leningrad region Murmansk region Novgorod region Pskov region Republic of Karelia Komi Republic

Belgorod region Bryansk region Vladimir region Voronezh region Ivanovo region Kaluga region Kostroma region Kursk region Lipetsk region Moscow and the region Oryol Region Ryazan Oblast Smolensk region Tambov Region Tver region Tula region Yaroslavskaya oblast
Kirov region Nizhny Novgorod Region Orenburg region Penza region Perm Territory Republic of Bashkortostan Mari El Republic The Republic of Mordovia Republic of Tatarstan Republic of Udmurtia Chuvash Republic Samara Region Saratov region Ulyanovsk region
Adygea Astrakhan region Volgograd region Krasnodar region Republic of Kalmykia Republic of Crimea Rostov region
COMPLETE BOILER INSTALL | Viessmann Vitodens 100-W
Karachay-Cherkess Republic The Republic of Dagestan Republic of Kabardino-Balkaria Republic of North Ossetia Stavropol region Chechen Republic
Altai region Zabaykalsky Krai Irkutsk region Kemerovo region Krasnoyarsk region Novosibirsk region Omsk region Altai Republic The Republic of Buryatia The Republic of Khakassia Tomsk region Chita region
Amurskaya Oblast Kamchatka Krai Magadan Region Primorsky Krai The Republic of Sakha (Yakutia) Sakhalin region Khabarovsk region
Thermostat Zont BT-2 GSM for gas boilers on the Opentherm ML00003983 protocol
Zont BT-2 is a thermostat for a heating system with built-in support for the OpenTherm protocol and its own SIM card. It is connected to the boiler electrical board to the OpenTherm connector and controls its operation. Teams can be transmitted to it from any phone, tablet or PC.
For ease of work, there are free phone applications and personal account on the site. To protect against unauthorized access, the entrance to the Personal Account is protected by password.
The zont bt-2 room thermostat is designed to control the required temperature in the house. Has its own SIM card and is connected to the heating boiler using the Opentherm protocol. You can control the device from the phone or tablet.
Автоматика ZONT H-1V обзор, монтаж и возможности. Цены в Описании.
Thermostat supports ten heating modes. For this, 10 temperature sensors are connected to the device, and you can simultaneously. Both radio submarines and wired. Thus, there may be either tropical heat or pleasant coolness in the room.
In addition, you can easily make a weekly schedule of the heating boiler for the most optimal consumption of electricity or gas.
Specifications:
- Power voltage: 24 in
- Maximum current consumed: 1000 mA
- Type of wired temperature sensors: digital, DS 18s20 or DS18B20
- Type of radio channel temperature sensors: Zont ml-703, ml-711, ml-719
- The maximum voltage of the switching contacts of the relay output: ~ 220 V, = 24 V
- The temperature range of work: from.30 to 55 ° C
- Built-in GSM modem, supports 2G, frequency range: 800, 900, 1800, 1900 mHz
- Mobile data transmission channel: GPRS
- GSM Antenna: external, connected
- Open exit time: no more than 50 seconds
- Dimensions: 140 x 105 x 30
- Mass: 0.250 kg
- Building material: plastic, fastening on any surface
GSM Thermostat Zont BT-2 can be controlled: remotely using: the Zont web service (through the personal account on the website www.Zont-Online.ru) Zont applications for mobile devices on the iOS and Android cell phone platform (SMS commands and via the call to the voice menu)
Manually using: external control panel Zont ML-726 or ML-732 of the external OpenTherm Bosch panel in
Functional capabilities of the thermostat Zont BT-2
State control and control of the boiler through the web service and the Zont mobile application-display of the current state of the boiler;. display of the current temperature of the room;. the choice of pre.installed modes to maintain a given temperature (air or coolant);. temperature monitoring (air, coolant, DHW);. programming the work of the boiler according to a weekly schedule;. control of the condition of additional sensors (leaks, gas leaks, security trips). Alerts of the owner of the boiler at:. deviation of the current temperature from specified threshold values;. accidents of the boiler and the malfunction of the boiler;. malfunctions of connected temperature sensors;. loss and when restoring the main voltage of the supply;. the operation of additional security sensors (the “security alarm” function). Recording and storing the history of events (over the past 3 months). the boiler operation and measured temperatures;. the time of the appearance of accidents and errors in the work of the boiler;. the time of loss and restoration of the main voltage of the supply;. time of incoming calls and the text of incoming SMS;.Dates and numbers of the version when updating for remote update from the Personal Cabinet of the Web Service.
Presentation, you can download here-FPI Zont BT-2