The operation of the gas boiler when turning off the electricity: will the unit work if there is no light?
When the light, the component of the heating system is also disconnected. Pumps, shut.off valves with electronic components, as well as protective automation cease to work.
Most of the owners simply do not know what to do with the gas boiler if the light is turned off.
In this article, we will tell you not only how to act in such situations, but also what are the consequences for the units and even residents of the house this entails.
Will a gas water heater work without electricity?
What elements of the boiler depend on electricity?
Stopping the power supply of houses not only in the outbacks, but also in cities occur quite often. They occur due to emergency situations, planned repair and technical work, and breakdowns on the line. And the most unpleasant thing is that when the electricity is turned off, the operation of a gas boiler is paralyzed if it is an energy.dependent type.
The energy.dependent gas boiler continues to function as usual, even if the power line is turned off on the power line. The only exception if the pump works with it, and the gravitational circulation system of the coolant is not provided.
Power.dependent boilers have a simple, basic set of functions. They are less comfortable in operation than their energy.dependent brothers. But their work does not depend on energy supply to the home power grid, and more often they are less likely to fail
In the heating circuit with a simple.type boiler, a set of main elements is about this:
- smoke removal system with natural thrust;
- heat exchanger;
- gas burner with nozzles for supplying gas, which is located in the combustion chamber;
- gas and ignition supply unit;
- expansion tank;
- mechanical thermal attemptor;
- The control module, which includes the boiler ignition system (mechanical or piezo), adjust the temperature regime;
- Security Group (safety valve, pressure gauge, air venture).
Energy.dependent devices are more complex in the device. But is it necessary and important to the functioning of a gas boiler is important and important?
Depending on the model and brand, in addition to the same basic set of elements, in some cases, electronic and automatic type, functions such as:
- forced ventilation system;
- built.in circulation pump;
- electronic system control module;
- shut-off-regulating reinforcement on an electric drive;
- various sensors. water duct, temperature, flame supply, water pressure in the systems, manostat, emergency complexes;
- piezorodzhiga unit with electric drive;
- Automatic temperature controllers;
- system of warning and remote control;
- display with the withdrawal of current indicators of the device
Units of this type are more reliable and much more convenient in operation, and in addition, they are economical. Automation can be set by switching and off modes, reducing fuel consumption, create a comfortable microclimate at home, do not worry about safety and performance.
Modern boilers are stuffed with electronics. When choosing a device, also install a voltage stabilizer to protect against jumps on the network
The only minus, after the electricity shutdown, the energy.dependent gas boiler will not be able to fully work. It is difficult to say which functions will be absent at all, it depends on the boiler model. Some units have a combined control system. mechanical and electronic.
Exactly that forced ventilation, automatic adjustment of flame supply to the burner, pump, display, electronic control module will not function, in general, all devices operating on electric drive and constant current supply.
Are interruptions with electricity dangerous?
Sellers of power.dependent devices and sources of uninterrupted nutrition tell customers chilling bikes that look rather believable. A person who does not understand anything at all in the device of the boiler will believe that with the disappearance of current, the supply of gas to the burner continues.
What is really happening? With the thermal attires off, the electronic control unit and the pump, uncontrolled fuel combustion in the combustion chamber occurs, which means that overheating of the fluid in the heat exchanger.
Accordingly, the tubes can not stand, deform, burst from them, extinguishes the burner of an atmospheric gas boiler. Gas enters the room and creates an explosive situation or simply poles people and animals. And if the boiler has a boost of the ventilation system. on the street. This is also unsafe and not environmentally friendly.
Agree, it sounds believable and scary? Already decided to run for a power.dependent boiler? And in vain!
Do not avoid maintenance of gas devices and their elements. The check will show their performance, especially after the power outages
In fact, electro.dependent boilers occupy a leading position in the sales market. They are installed in summer cottages, private houses, with owners spending half a day at work, non.residential premises in which a long repair is carried out.
Turning off electricity, as mentioned earlier, the process is quite frequent. And for some reason there is no data on the daily large-scale tragedies of carbon monoxide poisoning or explosions.
To the same, such a dangerous device would not have passed certification and could not correspond to GOST in any way, which means that its gazovers would not allow it to operate.
And now technical details. In fact, there is a reliable system in the instruments that ensures the shutdown of the boiler in the case of force majeure, including the cessation of electricity supply.
Can electricity turn off in the winter due to accumulated debt?
At the same time, the consumer must be notified in writing at least 10 days before the estimated date of introduction of restriction (power outage).
All the reasons why the supply of electricity is terminated, not counting the rupture of the contract between the supplier and the consumer, can be divided into two groups: technical and economic.

I live in Crimea, in Feodosia. When typing the number, the phone immediately turns off. And the question: a transit riser (MKD) passes through the apartment). In apartments, heating is individual. The first floor of the State Gosquitorship, which, in the process of not agreed on the repair of us-3rd and 2nd floor, flooded twice-cold and after 4 four days with hot water. The lower neighbor persuaded the defendant to make me. Who is the owner of a transit pipe?
Popular manufacturers
Almost all manufacturers of heating equipment are engaged in the production of gas boilers. European companies are considered recognized leaders in this area, but Korean models also received a high appreciation from Russian users. Recently, Russian gas boilers have appeared on the market, made taking into account the features of operation and the technological conditions of our country.

Consider the most famous companies producing gas boilers for heating a private house:
One of the most famous and reliable brands. Produces a wide range of heating boilers of all types.
All model lines are of high quality and reliability.
The assembly of equipment is carried out on the most modern equipment from high.quality materials.
Ariston Italy
Equipment successfully competing with boilers of any firms. There are model rulers adapted to operation in Russian conditions.
High.quality and reliable boilers capable of working in different conditions and rooms.

High-quality units, each model bears the name of any animal.
Inexpensive, but high.quality Korean boilers are highly appreciated among their owners.
Domestic equipment made taking into account the technical features and climate of Russia.
ZhMZ Russia
Power.dependent boilers, reliable and unpretentious in work.
The list of manufacturers can be continued for a long time, but simple transfer of any useful information will not give. For the right choice, you need to have special knowledge.
How an autonomous gas boiler works?
The device is connected to the gas channel and the water supply system. Depending on the device, the water passes through the system once or several times.
Boilers of a more complex design are equipped with sensors and automatic mechanisms of protection against overheating and emergency situations.
There are at least two burners in such equipment: the main and smell. When turning on, the piezoelectric element fuses the smell burner, and from it the ignition is transmitted to the main.
The main burner warms the heat exchanger and after the device goes into the waiting mode and heat conservation. When the lower temperatures are reached, the process is repeated.
Thermal energy from alternative sources
Can natural sources of thermal energy make an alternative to gas heating in a private house? Despite the development of this direction of energy, humanity will not refuse to burn out of the fossil and biological fuel. Alternative heating today is used only as an auxiliary option.
Using the heat pump
The principle of operation of the thermal pump is that the equipment helps to extract thermal energy from the natural source and move it into the room for heating it
When deciding how to warm the house using a heat pump, pay attention to the features of the options:
- “Air-air”-the equipment functions as a split system in heating mode.
- “Air-Wood”-the principle of operation is the same as in the first version, but the thermal energy of the outdoor air enters the water circuit and heating equipment.
- “Water-water”-thermal energy is extracted from a reservoir or groundwater and is used to heat the coolant;
- “Earth-Wood”-to extract thermal energy from the soil and heating the coolant, a geothermal circuit of pipes is mounted.
To make the house warm with these technologies, you will need to use electricity. To obtain 3-4 kW of heat, 1 kW of electricity is consumed. In conditions of limited electrical consumption, the heat pump is able to cope with the heat supply of the house with an area of up to 150 m2, provided that the climate is not characterized by prolonged frosts.
Installation of a heat pump for an autonomous heating system will cost a serious amount, and it is difficult to count on the fact that these costs will pay off in the coming years of operation.
Using a solar collector
Groups of glass tubes, according to which the coolant circulates, are designed to heat the sun, more precisely, by radiation of infrared spectra. Heating of a cottage without gas using only solar collectors is impossible :
- Effective heating is possible only in clear sunny weather in the warm season. in winter and in the gloomy days of the sun is not enough for the full functioning of the heating system;
- Before and after sunset, the collector does not receive thermal energy;
- The design is energy.dependent. so that the coolant circulates well, an electric motor is needed.
Among the best solutions for the use of alternative energy are the installation of a heat accumulator to accumulate thermal energy transmitted by the collector. This will help save energy, which is used by the main heat source (usually a solid fuel boiler).
TOP-5 rating of power-dependent gas boilers
Consider the features of some models of energy.dependent units:
Lemax premium-12.5
Power.dependent flooring boiler of domestic production. The power of the unit is 12.5 kW, so the area of the room should not exceed 125 square meters. m.
The model is equipped with a steel heat exchanger, overheating protection and gas supply controller.
Main performance:
- Efficiency. 90 %;
- the maximum temperature of heating water is 90 °;
- the pressure in the heating circuit (Max). up to 3 bar;
- natural gas consumption. 1.5 m3/h;
- dimensions (Sh-B-G)-416x744x491 mm;
- mass. 55 kg.
Oil Heat Boilers. How it works. Understand the Basics
The Lemax company gives a long guarantee for its boilers. the user receives technical support for 3 years.
Lemax premium-20
Another floor, energy.dependent gas boiler made in Taganrog.
Its capacity is 20 kW, which is optimal for most private two.story houses. The maximum area for this unit is 200 kV. m.
- Efficiency. 90 %;
- the maximum temperature of heating water is 90 °;
- the pressure in the heating circuit (Max). up to 3 bar;
- natural gas consumption. 2.4 m3/h;
- dimensions (Sh-B-G)-556x961x470 mm;
- mass. 78 kg.
A single.circuit design is designed to heat the coolant, but if necessary, you can connect an external boiler of indirect heating.
Lemax Patriot-12.5
Energy.dependent parapet model from Taganrog. A boiler with specific capabilities.
A power.dependent unit, but a closed combustion chamber. The capacity of the boiler is 12.5 kW suitable for heating 125 kV. m.
Main technical characteristics:
- Efficiency. 87 %;
- the maximum temperature of heating water is 80 °;
- pressure in the heating circuit (Max). up to 2 bar;
- natural gas consumption. 0.75 m3/h;
- dimensions (Sh-B-G)-595x740x360 mm;
- mass. 50 kg.
The main advantage of parapet boilers is the low fuel consumption. almost half as compared to ordinary models.

Siberia 11
Products of the Rostov manufacturers of heat engineering. Units are produced in one and double-circuit options, which expands the possibilities of choosing.
The capacity is 11.6 kW, allowing to heat the house with an area of up to 125 square meters. m.
- Efficiency. 90 %;
- the maximum temperature of heating water is 90 °;
- pressure in the heating circuit (Max). to the bar;
- natural gas consumption. 1.18 m3/h;
- dimensions (Sh-B-G)-280x850x560 mm;
- mass. 56 kg.
Rostov units are positively evaluated by specialists and ordinary users.
Mora-Top Sa 40 G
Czech gas power.dependent boiler with a capacity of 35 kW is designed for use in rooms up to 350 kV. m. The massive structure is equipped with a cast.iron heat exchanger.
- Efficiency. 92 %;
- the maximum temperature of heating water is 85 °;
- pressure in the heating circuit (Max). to the bar;
- natural gas consumption. 3.9 m3/h;
- dimensions (Sh-B-G)-630x845x525 mm;
- mass. 151 kg.
Cast iron heat exchanger has a sectional structure of 5 departments. There are pressure and temperature sensors.
TOP-5 rating of power-dependent gas boilers
Consider the features of some models of energy.dependent units:
Lemax premium-12.5
Power.dependent flooring boiler of domestic production. The power of the unit is 12.5 kW, so the area of the room should not exceed 125 square meters. m.
The model is equipped with a steel heat exchanger, overheating protection and gas supply controller.
Main performance:
- Efficiency. 90 %;
- the maximum temperature of heating water is 90 °;
- the pressure in the heating circuit (Max). up to 3 bar;
- natural gas consumption. 1.5 m3/h;
- dimensions (Sh-B-G)-416x744x491 mm;
- mass. 55 kg.
The Lemax company gives a long guarantee for its boilers. the user receives technical support for 3 years.
Lemax premium-20
Another floor, energy.dependent gas boiler made in Taganrog.
Its capacity is 20 kW, which is optimal for most private two.story houses. The maximum area for this unit is 200 kV. m.
- Efficiency. 90 %;
- the maximum temperature of heating water is 90 °;
- the pressure in the heating circuit (Max). up to 3 bar;
- natural gas consumption. 2.4 m3/h;
- dimensions (Sh-B-G)-556x961x470 mm;
- mass. 78 kg.
A single.circuit design is designed to heat the coolant, but if necessary, you can connect an external boiler of indirect heating.
Lemax Patriot-12.5
Energy.dependent parapet model from Taganrog. A boiler with specific capabilities.
A power.dependent unit, but a closed combustion chamber. The capacity of the boiler is 12.5 kW suitable for heating 125 kV. m.
Main technical characteristics:
- Efficiency. 87 %;
- the maximum temperature of heating water is 80 °;
- pressure in the heating circuit (Max). up to 2 bar;
- natural gas consumption. 0.75 m3/h;
- dimensions (Sh-B-G)-595x740x360 mm;
- mass. 50 kg.
The main advantage of parapet boilers is the low fuel consumption. almost half as compared to ordinary models.
Siberia 11
Products of the Rostov manufacturers of heat engineering. Units are produced in one and double-circuit options, which expands the possibilities of choosing.
The capacity is 11.6 kW, allowing to heat the house with an area of up to 125 square meters. m.
- Efficiency. 90 %;
- the maximum temperature of heating water is 90 °;
- pressure in the heating circuit (Max). to the bar;
- natural gas consumption. 1.18 m3/h;
- dimensions (Sh-B-G)-280x850x560 mm;
- mass. 56 kg.
Rostov units are positively evaluated by specialists and ordinary users.
Mora-Top Sa 40 G
Czech gas power.dependent boiler with a capacity of 35 kW is designed for use in rooms up to 350 kV. m. The massive structure is equipped with a cast.iron heat exchanger.
- Efficiency. 92 %;
- the maximum temperature of heating water is 85 °;
- pressure in the heating circuit (Max). to the bar;
- natural gas consumption. 3.9 m3/h;
- dimensions (Sh-B-G)-630x845x525 mm;
- mass. 151 kg.
Cast iron heat exchanger has a sectional structure of 5 departments. There are pressure and temperature sensors.