What to do if the air conditioner is flowing? How to deal with the fact that water is dripping from the air conditioner?
First you should clarify. where, when and why water appears in the air conditioner. Everything is simple. it is condensation, the product of the transformation of the water vapor contained in the air, into a liquid state when it is cooling.
Thus, the higher the level of air humidity, the more condensate (water) will appear in the air conditioner. For example, even the smallest in power of a household air conditioner is able to drain air up to 1 liter per hour. How much specifically in a particular case is the water is impossible to say, it all depends on the humidity of the air, its temperature and of course on the desired mark of the thermometer inside the room.
How to eliminate leaks
The method of eliminating leaks directly depends on the cause of the breakdown.

Lack of refrigerant
In this case, the external part of the evaporator is freezing with further melting of frost after turning off the system. Typically, such a problem is accompanied by atypical sound and slight blowing of ice.
Damage to the drainage line
This breakdown most often occurs during the testing of the system with poor.quality installation. The cause of the malfunction is mechanical damage to the pipeline. It must be replaced. soldering, winding with island and gluing are extremely undesirable.
Clogging of a drainage pipe
If the outer tube is not equipped with a net, over time it turns out to be a clogged web, insect cocoons, dust or dirt. In winter, its complete icing may take place. To correct the situation, you need to clean the pipeline with wire or vacuum cleaner, in the frosts you will have to carefully beat off the ice.
Lack of pressure supply regulator
Most often, in winter, when there is a significant distortion of pressure and temperature of the circuit of the entire system. Heating the evaporator of the internal unit decreases, condensation is formed and, as a result, ice. When the temperature rises, the walls of the evaporator are thawed and the leak occurs. The solution to the issue can only be the installation of a pressure regulator.
The use of pseudosphones
Often, when installing equipment to prevent the penetration of an unpleasant odor, the wastewater pipe bends. This leads to malfunctions, so the deformed area will have to be replaced, while it is best to use original siphons.
Installation of a drainage line without a slope
As already mentioned, this error occurs when trying to independently install the air conditioner with gravity exit. In this case, the internal block turns into a large tank of water and becomes extremely dangerous for people in the room. To eliminate such an error, the dismantling of the entire system and its complex re.equipment will be required.
In a situation, if the water output to the street is not possible for any reason, air conditioners with a drainage pump are installed, for example, in basement or underground structures. Such equipment can also give leaks.

Drainage breakdown. condensate is not completely absorbed. Such equipment must be repaired or completely replaced.
In the case of an unintentional shutdown of electricity or voltage difference in the network, an insignificant leak sometimes appears on the network. Do not worry. when the current is resumed, the problem is quickly eliminated.
The causes of water flowing from the external unit
Reduced level of refrigerant. The ice crust formed on the tubes melts and flows through the technical gaps of the outer unit.
How to eliminate. Refuel the air conditioner with freon.
Evaporator pollution. Violation of the delivery of heat by the evaporator into the atmosphere due to pollution of its surface with dust, dirt, fluff, etc.P. leads to its freezing and the formation of a “drop”.
How to eliminate. Timely conduct of preventive and seasonal cleaning of the evaporator.
Reduction in pressure in the freon pipeline during the period of decrease in external temperature.
How to eliminate. To prevent the occurrence of the problem, the condensation pressure regulator is set. Specialized climatics, for example, in server, is equipped with pressure regulators initially.
Air conditioning “Fuck” after several years of work.
If the air conditioner, who worked for you with faith and truth for several years, suddenly flow. The reason lies in the absence or improper maintenance.
- The drainage pipe clogged. Dust, insect, etc. may accumulate in the hose.P. which will lead to a decrease or overlap of the water duct. There have been cases that in the pipe, in search of water in a hot period, Juke crawled, which subsequently stuck and blocked the entire drainage channel. Solution: Carry out a drain channel.
- Freon leak. A rather flying refrigerant circulates through the freon pipeline. Freon, which is enough microcracks to disappear from the refrigerator. The normalized refrigerant leak is 6-8% per year, even if the system is sealed. With a decrease in the amount of freon in the system, the evaporator of the internal unit is freezing. A semblance of hoarfrost is formed, in severe cases a snow fur coat. In this case, the condensate does not flow into the tray tray, but drips directly on the blinds, from them to the room. With a working air conditioner, it often looks like a “spit” with water. Water cannot drain into the pallet, a drop under its own weight breaks away from the rib of the heat exchanger, falls down, enters the fan of the inner unit, which is thrown out. Solution: Check the air conditioner for a freon leak, if necessary, refuel the air conditioner. This procedure requires certain knowledge, skills, tools. Trust this work to professionals.
What to do?
Consider how to eliminate malfunctions with your own hands:
- In the first case, there is nothing complicated-it is necessary to pour the condensate accumulated there from the container, and then install it in place, and the split system will work normally. Of course, this must be done after it is disconnected and, preferably, after washing. Follow the accumulation of condensate to avoid leak.
- If the air conditioner flows due to ice-exchange part-exchanging part, then make thermal insulation, for example, using glass wool, so that there is no such reaction to temperature changes.
- If the drainage pump is broken and drunk, it must, of course, be fixed or replaced, but for this you should contact the specialist air conditioners who, at the proper level, will perform repairs and diagnostics.
- If the water is dripping, because the hose is placed incorrectly, then place it under the required slope.
- Weak fastening of the pipes can be improved by enhancing the mounting with nuts, and for the fortress you can treat with sealant. But do not clamp until the thread breakdown.
- Constantly check the amount of liquid so that there is no excessive accumulation, and the split system does not flow.
Another reason for the breakdown is the clogging of the drainage tube. How to fix this malfunction with your own hands is described
Thus, part of the causes of the leak of the air conditioner may well be eliminated on their own. But in more complex cases, it is better, of course, to contact specialists. For example, such a moment when the internal block itself has drunk. Here the reason is most likely to be available inside defects. chips, cracks. Of course, you can try to fill them with a gluing composition, but the analysis of the device is best entrusted to the specialist.
Two left hands installers
Problems with condensation can begin shortly after installing the air conditioner. In 99% of cases, this due to unprofessional (in some cases of drunk) installers.
The fact is that the drainage tube should go down downward downward. Sometimes when installing in the wall, a hole is made, which goes parallel to the ground, or even directed upward. In this case, according to the law of gravity, moisture will not be able to leak and accumulate in the tray.
It is easy to determine the problem. just look at the entrance and exit of the drainage from the wall.
VRF/VRV HVAC Systems | Working principle and benefits
There are two exits. either punch a new hole, or outweigh the air conditioner higher. But it is best to call the installers. They are simply required to correct their mistake.
If you put the air conditioner yourself, you will have to arm yourself with a peorator and choose. Naturally, it will be easier to break through a new hole. Its entrance should begin in the same place as the old one, but the channel should be directed down.
How to deal with it
Calls for cleanliness here you can not do. There is still dust in the air, and it will certainly get inside the system. The manufacturer took care of this, installing mesh filters behind bars.
And these filters must be kept clean. At the end of the season, and best. once a month, nets should be removed from the body, rinse and dry. In addition, the heat exchanger of the radiator (ribs) should be washed periodically. If the drainage is not clogged, dirty water will calmly go outside.
How Air Conditioning Works
Also for sure, you need to clean the fan turbine. The same dust falls on the blades, and it can lead to vibrations and breakdown.
The baton itself for collecting condensate is an excellent garbage pit. Heavy particles of dust settle to the bottom, and serve as an excellent workpiece for the formation of a jam at the entrance to the drainage. Again, before the start of the season, it is necessary to clean the body from the inside.
Prevention of the drainage system
Without waiting for the flood from the inner block, it is necessary to regularly clean the tube connecting both air conditioning modules. To do this, you can use a tool to eliminate blockages in the sink, enema (creating water pressure), pump for a beach mattress. To check the patency of the drainage, pour a glass of water into the bath for condensate. The liquid should disappear in a few seconds.
Check the condition of the external parts of the drainage. If a flexible tube outside the wall dangles in the wind, fix it.
Be sure to check the tightness of the drainage connection with the outer tube before the start of the season. A couple of meters of airtight film costs a penny, unlike spoiled wallpaper on the wall.
Experts advise
Here are a few more Комментарии и мнения владельцев and tips of professionals who are engaged in installing, establishing, and repairing cooling devices. Generally the most common reason that the air conditioner flows, they call clogging of drainage capacity. If you neglect its service cleaning, then in the end it will clog. Mud, wasps, spiders, and other insects get into the pipe. The question often arises. what insects do inside the tube? They, like all living in summer, are attracted by water. Some even settled there. Inventive owners of air conditioners, it happens, put on a mosquito net at the end of the tube, but it also clogs over time.
Since the diameter of the hole of the drainage tube is about 1 cm, and it is clogged, when the split system operation, the water drips through the inner block into the apartment, not through the tube to the street. It is better to entrust the solution of the problem of cleaning to specialists. After disconnecting the air conditioner and after washing it, the problem will be completely eliminated, the drainage system is cleaned.
Often in the fact that water is dripping from the body, an independent human factor is to blame. So, during the repair, it happens that it must be rearranged a little higher, lower, or to the side (especially when the repair concerns the ceilings in the room). In this case, if this is done without the participation of specialists, the angle of inclination of the drainage may change, and the water does not flows outside, as it should, but drips to the room. Here you can not do without the participation of the working service, t. to. it is necessary to drill a new hole and shift the communication. In addition, during the currently popular high.altitude insulation work, industrial climbers, as the experience testifies, can smear the drainage with putty (if the neighbors are dripping from above), and bend up the end of the drainage tube. Here, of course, in order to eliminate the leak, you need to redo the intervention of negligent workers.
Block: 4/5 | Summer characters: 1841
Experts advise
Here are a few more Комментарии и мнения владельцев and tips of professionals who are engaged in installing, establishing, and repairing cooling devices. Generally the most common reason that the air conditioner flows, they call clogging of drainage capacity. If you neglect its service cleaning, then in the end it will clog. Mud, wasps, spiders, and other insects get into the pipe. The question often arises. what insects do inside the tube? They, like all living in summer, are attracted by water. Some even settled there. Inventive owners of air conditioners, it happens, put on a mosquito net at the end of the tube, but it also clogs over time.
Since the diameter of the hole of the drainage tube is about 1 cm, and it is clogged, when the split system operation, the water drips through the inner block into the apartment, not through the tube to the street. It is better to entrust the solution of the problem of cleaning to specialists. After disconnecting the air conditioner and after washing it, the problem will be completely eliminated, the drainage system is cleaned.
Often in the fact that water is dripping from the body, an independent human factor is to blame. So, during the repair, it happens that it must be rearranged a little higher, lower, or to the side (especially when the repair concerns the ceilings in the room). In this case, if this is done without the participation of specialists, the angle of inclination of the drainage may change, and the water does not flows outside, as it should, but drips to the room. Here you can not do without the participation of the working service, t. to. it is necessary to drill a new hole and shift the communication. In addition, during the currently popular high.altitude insulation work, industrial climbers, as the experience testifies, can smear the drainage with putty (if the neighbors are dripping from above), and bend up the end of the drainage tube. Here, of course, in order to eliminate the leak, you need to redo the intervention of negligent workers.