Home Refrigerators Pozis refrigerator why doesn’t work
Refrigerators

Pozis refrigerator why doesn’t work

Question answer

Good afternoon! Interested in the refrigerator of a two-chamber household Pozis RK-102. Tell me, please, the dimensions of the lower box in the freezer of the refrigerator?

The overall dimensions of the lower basket of VHSHHG, mm: 207x475x285.

Tel/fax: 7 (84371) 5-28-18 Web: www.Pozis.ru mail: itc@pozis.ru

Good afternoon! Tell me, please, what material the tubes are made on the evaporator? What material baskets are made of? Interested in the freezer camp Pozis FH-250-1.

Evaporator tube material. aluminum. Materials of baskets are polyethylene.

Tel/fax: 7 (84371) 5-28-18 Web: www.Pozis.ru mail: itc@pozis.ru

Good afternoon! I would like to purchase from the plant a refrigerator Pozis RK FNF-173 with an electronic block. Tell me how it is possible?

Thanks for the interest in our products. In the “Support” section on our website you can find out where to purchase our products. It is possible to purchase in stores and on the sites: Ozon, Wildberries, Yandex Market, DNS, Citylink, RBT, Center Corporation and others. You can also turn to the proprietary store JSC “POSIS” in g. Zelenodolsk at: ul. Volzhskaya d.ten. tel. 8 (84371) 5-39-70 mode of operation: from 9.00 to 18-00 lunch 13-00 to 14-00 Saturday 8-00 to 16-00 without lunch.

Sincerely, Product deliveries management company Pozis

tel. 7 (84371) 5-27-01 Mailto: Sales@pozis.ru web: www.Pozis.ru

Allows transportation in a horizontal position, in the presence of corresponding manipulation signs on the package. If there is no packaging, then you must adhere to the rule. the absorption tube emerging from the compressor should look upstairs.

Tel/fax: 7 (84371) 5-28-18 Web: www.Pozis.ru mail: itc@pozis.ru

On the scoreboard of the refrigerating chamber of the Khl-250 “Pozis” refrigerator, the fan icon is constantly burning, and it works (fan), without stopping, how to convert the fan into automatic mode? Just bought a refrigerator.

In HL-250, the fan operates constantly with a closed door. This is fine.

Sincerely, deputy chief designer Pozis Suleimanov Robert Lokmanovich

Tel: 7 (84371) 5-28-18 Mailto: NTC-Med@pozis.ru web: www.Pozis.ru

Good morning! I want to make a purchase of Larya FH-258-1 on your site, but I can not put the stall in the basket. Tell me how to do it? And I would like to know the price.

Good afternoon! Thanks for the interest in our products. We are a manufacturer, our site is informational in fact that the buyer can familiarize ourselves with our company and products that we produce. In the “Support” section, you can find out where to purchase our products. You can purchase our products in stores and on sites: Wildberries, Yandex Market, DNS, Citylink, RBT, Center Corporation and others. In the Republic of Mari El, you can contact our dealers: LLC “Artes” (magician. “Autocar-service”) g. Yoshkar-Ola tel.: (8362) 64-00-28; IP Bautin a.E. (magician. “Hostess”) g. Volzhsk tel.: (83631) 6-45-99;

Sincerely, Product deliveries management company Pozis

How to Fix Whirlpool Refrigerator Not Getting Cold Cheap and Easy

tel. 7 (84371) 5-27-01 Mailto: Sales@pozis.ru web: www.Pozis.ru

Good afternoon! Which of the refrigerators 280 has the ability to adjust temperatures both in the lower and in the upper chamber (separately)

KHFD-280 and KHFD-280-1 have two independent refrigerator chambers.

Sincerely, deputy chief designer Pozis Suleimanov Robert Lokmanovich

Tel: 7 (84371) 5-28-18 Mailto: NTC-Med@pozis.ru web: www.Pozis.ru

Allows transportation in a horizontal position, in the presence of appropriate manipulation signs on the package. If there is no packaging, then you must adhere to the rule. the absorption tube emerging from the compressor should look upstairs.

Sincerely, Korolev D.M. Pozis Tel/Fax: 7 (84371) 5-28-18 Web: www.Pozis.ru mail: itc@pozis.ru

Good afternoon! Please, tell me, whether the humidity is maintained in the refrigerator of the pharmaceutical KhF-250-3 “Pozis”? If so, what. I want to buy for cheese ripening. I know that such refrigerators are used by home cheese. The optimal environment for ripening cheese is 10-12 degrees, 85% humidity. Is it possible to set such parameters?

Humidity in pharmaceutical refrigerators is not supported.

Sincerely, deputy chief designer Pozis Suleimanov Robert Lokmanovich

The reasons

You need to know the features of the main malfunctions. So it will be possible to decide whether to repair it yourself or seek help from a specialist.

The cord is pulled out

Before calling the wizard, it is necessary to check whether the device is connected to the mains, whether the electricity indicator is burning. It may turn out that there is no problem, and your two.chamber friend works properly. you just need to include it in the outlet.

The door is not closed

Even the minimum gap between the door seal and the body will significantly reduce the performance of the device. Make sure the door is tightly adjacent.

The seal broke or sagged

If the rubber gasket is torn, you will have to buy a new. Try to find the original detail.

If the seal becomes too hard (from old age or some types of household chemicals), then it is not necessary to immediately change it. You can try to restore elasticity with improvised means. Simple methods in execution and cheap.

  • Today, the seal is usually fixed with foam, glue or starts in a special groove. Dismantling in this case does not cause special difficulties.
  • In Soviet models, the elastic band is mounted on nails or rivets. When removing, it is necessary to act carefully so as not to damage the element.

To restore elasticity, you will need to boil several liters of water and scald the rubber.

Leave the seal in hot fluid until completely cooled. Often, such a procedure helps rubber to return the properties lost over time.

The defrosting mode is enabled

Sometimes you can not notice or just forget that the refrigerator is working in defrosting mode. Just switch it to cooling mode.

High temperature is set

In the summer on a hot day, under the influence of sunlight in the upper plus chamber, the temperature may rise. For normal performance, taking into account changes in external factors, the thermostat should be adjusted.

In hot times, it is undesirable to install it to the maximum, as the compressor may fail.

The temperature sensor broke

Often, if a modern refrigerator does not freeze, the temperature sensor is buggy. Due to the transmission of incorrect indications to the “electronic brain”, the system does not apply to the compressor to turn on. The new one costs inexpensively, but the life of the operation directly depends on the quality of the sensor.

In the technique of the old format, the so.called thermallela (thermostat) fails, more about the repair here.

The compressor engine burned or overheated

The fact that the compressor engine failed is out of order by such signs:

  • When opening the door, the light lights up, but the refrigerator itself does not work and does not cool the products.
  • The motor turns on and is disconnected almost immediately. Before turning off, you can hear a click of relay (more about strange sounds). The light burns, but none of the cameras freezes.
  • The electric motor is buzzing, but no cooling.

With such a breakdown, an element replacement is required.

If the compressor overheats, the device may also not freeze. The cause usually becomes out of order of a start.up relay. For repair, you must contact a specialist.

Exact fan

Such a problem may appear in devices equipped with the No Frost system.

  • If the device is frozen in the device, the temperature regime of the entire cooling system is disturbed. It happens extremely rarely, complete defrosting will help.
  • The fan works continuously, making a characteristic buzzing sound. The system cannot cool the chambers to the required temperature due to the ice of the intended in the air routes. To solve the problem, it is necessary to defrost the refrigerator within 12 hours.

Freon leak

For repair, you need to find a leakage place, eliminate it, change the filter-dryer, and also season the cooling system with freon.

In one-compressor models about the output of the cooling gas, such signs can signal:

  • After defrosting, the light inside the chamber lights up, but the refrigerator does not freeze and does not turn on.
  • The compressor works constantly, but the device cools poorly.
  • After defrosting, the unit worked a little, but then turned off and does not turn on.

In two-compressor models, the signs of leakage are the same, but only one compartment belongs: the upper or freezer.

Usually it occurs in the evaporator, the rations of the tubes and in the heating circuit. Read more about this here.

Glits of electronic blocks

During a breakdown of the control unit, the refrigerator can behave unpredictably or not work at all. The temperature in different chambers will jump. The device can turn on for only a few seconds, and then turn off again.

In modern models, the breakdown is accompanied by light (red.flavor flashes or burns) or sound signals that notify the temperature increase.

Those with the display give a text message with an error on the liquid crystal screen.

Most often the reason is moisture. This usually happens when defrosting. It will be necessary to repair the control module or replace it assembly.

Dead Tenn defrost

Sometimes, if the refrigerator does not freeze, heat and outgoing air cavities are clogged with ice. This happens when the heating is burning for the defrosting of ice in these cavities.

To diagnose the problem, it is necessary to defrost the camera, and then check the performance of the heater. This is a universal element that promotes thawing ice and snow cover.

Damage to the evaporator

With the evaporator (radiator on the back wall) there may be such problems:

  • Flowing with oil. To eliminate the malfunction, you need to unscrew the system where the compressor and the capillary tube are connected. Evaporator, capillary and absorption tube are washed with liquid colad.
  • Freon leakage. It is necessary to replace the evaporator.
  • The refrigerator works continuously (temporarily does not turn off). This indicates the absence of contact of the absorption tube of the evaporator and the siphon tube of the thermoregulator.

If the No Frost system is installed

Almost all the difficulties described above relate to models with the No Frost system.

  • Freon leak.
  • Compressor breakdown.
  • The failure of the thermostat.
  • Ten malfunction.
  • Fan freezing.
  • Incorrect operation of the control unit.

In order not to damage anything else, it is advisable to contact a specialist. Independent repair should be done only if there is at least initial knowledge in this area.

The most likely reasons for the malfunction of the freezer

There are breakdowns connected directly with the fact that the freezer department is turned off. Knowing their symptoms and signs, you can easily diagnose a failure and save on the initial diagnosis.

All possible reasons for the failure of the freezer in the Bosch (Bosch), Samsung, Whirlpool, Liebherr (Liebherr), Minsk and others are collected in the table below.

The compressor is broken up for the operation of the freezer compartment.

The air sensor of the freezer broke.

The thermostat of the freezer was broken.

In models equipped with one compressor, the No Frost system and a “crying” type evaporator, a switching valve may break.

The leakage of the refrigerant in the area of ​​the steel circuit is not excluded.

In models with a lower freezer and an evaporator of a “crying” type, this problem is not uncommon. It is provoked by blocks of the drainage hole, due to which the water accumulates in the main chamber and flows into the lower compartment area.

Acting inadvertently in the hope of quickly defrosting the refrigerator, you can pierce the camera, which will cause the inevitable leakage of the refrigerant from the system.

Most likely, the control module broke.

Do I need to care for the freezer? Definitely necessary! Even if you bought the No Frost model, it also needs to be defrosting-not as frequent as a drip refrigerator, but at least 2-3 times a year. It is also worth periodically wipe the walls and containers, inspect the camera at the time of freezing, throw out extra products. In the summer, slightly reduce the temperature so that the compressor does not overwhelm. And most importantly: if you are a “frost lover” for the winter, freeze fruits and vegetables in batches, never load the camera completely.

Now you know for what reasons the freezer of your two.chamber refrigerator may not work. If you have a single.chamber model, a separately freezer compartment cannot fail, since these chambers have a common system.

Using our table, determine why there was a breakdown to know for what repair to prepare-small or capital. And if the thermostat or sensor can be replaced with your own hands, then works such as replacing the compressor or refueling of the freon require special equipment and experience. Therefore, we recommend that complex tasks be entrusted to the master.

Popular models

We offer a detailed description of the characteristics and features of the most purchased refrigerators “POSIS”.

RK FNF-170

White case, lower arrangement of the freezer. Electromechanical type of control. The energy efficiency class corresponds to the value of A. 1 engine-compressor is installed on two cameras. Dimensions: 60x64x186 cm.

Freezer: installed no frost; Minimum temperature:.18 degrees; Volume: 94 liters.

Basic compartment: No Frost is also provided; the volume is 220 liters; Shelves are glass.

Noisiness. not higher than 40 dB. Weight. 73 kg.

I do not want to talk about the pros and cons of a particular model, because this is the most ordinary refrigerator. But I will tell you how it was as a whole: a week after the purchase, I began to flow. At the bottom of the freezer found ice (despite “No Frost”). it turned out that this ice melts, hence the puddles. But that’s not all. The master said that the water pipe was packed in a film, which is why the drain drains and the floods began. After removing the film, everything became good. freezes, does not make noise, does not freeze. But the impression is well spoiled.

Excellent price and quality since Soviet times. this is what bribed me. The cameras are spacious, the cabinet is compact. The walls do not freeze, the freezer too. I leaked a little, but I figured out and corrected the position of the drain pipe. There were no breakdowns for six months of operation, I hope that this will happen in the future.

RK FNF-172 W R

Another electromechanical option with a lower freezer. Energy consumption class. a, dimensions: 60x65x202 cm (ShHHHV). There are no frost in two compartments. The power of the freezer. up to 10 kg of products per day. Maximum can freeze to.18 degrees. General dedication of the device. 344.

  • Antibacterial spraying.
  • Glass strong shelves.
  • Doors hitch on any direction.
  • Noisiness. up to 40 dB.
  • Weight. 77.5 kg.

I bought my mother, according to her applications. I asked for an inexpensive device with a large freezer for summer frosts-all kinds of fruits-berries. I liked it outwardly, and inside everything is simple. Minus. noisy. But mom has a great dream, so she does not complain, but as a user I must note this. In general, the technique is ordinary. without delights, therefore there is nothing special to describe. Its price should work out in full.

RS-411 GF

Small one.door option made in black. Suitable for minimalists with commitment to dark shades. Like models, this one is equipped exclusively by electromechanics, and the energy consumption class is invariably a. The dimensions of the case are 54x55x85 cm. As you can see, this compact “assistant” will easily get up even in a small kitchen.

Inside there is a freezer compartment with manual defrosting. A drip system is installed in the refrigerator.

On a note! Minimum freezer:.12 degrees.

The total volume of the cabinet is 120 liters, of which 14 are on the freezer.

Metal shelves, noise. not higher than 40 dB, climatic class. N, weight. only 43 kg.

There were questions on the instructions. did not understand how temperature setup. Only then I found out that the adjustment is elementary. I was simply afraid to wind up too much. Freezes weakly, but at least does not flow (read other reviews) and does not rattle at night.

Typical malfunctions

Despite the technological work described above, the “POSIS” malfunction is a common thing. High.strength cooling system. luxury for the domestic manufacturer. If you improve quality, this will “hit” at cost, and in conditions of wild competition, the technique is unlikely to be in demand among users. After all, the priority is often the price.

There are a number of typical breakdowns characteristic of POZIS equipment:

  • Problems with electrical wiring. Implies the lack of nutrition of a starting protective relay (PZR). It can also be damage to insulation or burning contacts.
  • Damage to the thermostat.
  • PZR.
  • Damage of the engine-compressor.

Masters note that due to prolonged use of the electrical appliance, clogs of the capillary pipeline and filter-dryer are not excluded.

  • The freezer does not freeze;
  • The main department does not work;
  • the compressor does not turn off;
  • Water accumulates under boxes for vegetables and fruits;
  • water flows from under the case and t.D.

Fortunately, a simple device of equipment allows it to be successfully fixed. Some details amenable to repair, some of them need to be changed.

Fact! Masters note that since there is no electronic circuit-this excludes a dozen or two possible breakdowns.

So, Pozis refrigerators are not the highest quality technique in the market, but quite cheap. In this case, a simple device in the event of a breakdown provides a quick and relatively inexpensive repair. Option for those who want to save and support a domestic manufacturer at the same time.

Malfunctions of the refrigerators of the turquoise and their elimination

Damage to the thermostat in models with electromechanical control

In the refrigerators of the turquois, the thermostat is responsible for the cooling adjustment: it determines the temperature in the chambers and gives the command motor-compressor to turn on and off. Most often, the thermostat fails due to prolonged operation, due to moisture, due to loss of tightness or voltage jumps.

The turquoise refrigerator does not cool: in both cells heat. The motor does not turn on at all or turns on for a short time. In this case, the light in the refrigerator compartment when opening the door is on fire. Sometimes, on the contrary, the technique is rewriting: the compressor works with small breaks, a snowy “fur coat” increases on the back wall in the refrigerator in the refrigerator.

Faulty thermostat must be replaced with a new.

Damage of the engine-compressor

The compressor motor is responsible for the circulation of the refrigerant on the freon pipeline. Due to this, cooling occurs. In the turquoys engines, a cliff of windings, inter.threaded circuits, closing windings on the case arise. Sometimes the compressor “wedges”, and it buzzes, but does not download the refrigerant.

The refrigerator does not freeze: since most turquoise models have one motor-compressor, heat both in the refrigerator and in the freezer.

  • During inter.flower circuits or closing of windings, the sound of the engine is heard on the housing, then the click of the launcher.protective relay and after a few seconds the engine turns off. Perhaps, at the same time knocks out the machine in the apartment. If you touch the compressor with your hand, it is hot.
  • With a break in windings, the faulty motor does not turn on at all.
  • When compressor wear, the motor works almost without a break, but does not create sufficient pressure to cool, so warmth in both chambers.

The motor is not repaired, you will need to replace with a new.

Refrigerant leak in the evaporator

The evaporator is a section of the freon pipeline, where the consumption evaporates, due to which heat from chambers is taken. In single.chamber models of Biryusa (traditional Soviet refrigerators with a manual defrosting system), the evaporator is made of aluminum and is located in the freezer. It is often damaged mechanically during defrosting, trying to repulse the ice with sharp objects, or in it there is a micro-other due to corrosion.

There are two evaporators in two.chamber models without No Frost, one in the freezer, the other in the refrigerator on the back wall or behind it. The leak mainly occurs in the evaporator of the refrigerator. This is due, firstly, with the fact that it is made of aluminum, which is subject to corrosion, and secondly, it constantly works in humid conditions, when the temperature is positive (during the compressor recreation mode), then negative. For these reasons, microcracks appear in the evaporator, and there is a leak of freon.

The refrigerator is poorly freezing. The motor works, I practically do not disconnect. The evaporator may be visible uneven growth from ice and snow. Biryusa reports a malfunction with a blink of red indicator.

The master conducts diagnostics and finds the place of the freon leakage. Depending on the design of the refrigerator and the exact place of the leak, either the solder’s solder is produced or its replacement. If the evaporator is located in the inaccessible steamed part, the old evaporator is cut and the canopy of the new one on the back wall of the refrigerator is performed.

Damage to the launcher of the motor relay

The start.up relay performs two functions: starting. when the compressor is turned on, and the protective one. if an inter.seal closing or other breakdown occurred in the motor, accompanied by a strong heating of the compressor, the relay forcibly turns off the engine to avoid melting the working winding of the motor.

The turquoise refrigerator turns on and immediately turns off or does not turn on at all. The temperature in the chambers is increased. In the second case, the light in the refrigerator does not burn.

The launcher relay must be replaced with a new.

Blockage in a capillary pipeline

Capillary pipeline. a section of the freon pipeline with a diameter of not more than 50 mm. It creates a pressure difference: when moving along the capercay, the pressure of the freon drops, and when the refrigerant enters the evaporator, it boils and takes the heat. However, according to the system, not only Freon itself circulates, but also oil from the engine-compressor. During their interaction, paraffins are formed, which are deposited on the walls of the capillary pipeline and lead to suction.

Biryusa refrigerator is badly freezing. The motor works constantly and almost does not turn off. The refrigerator reports a violation of the temperature regime using a red LED.

With a partial blockage, the master tries to pave it with a special jack. But more often you have to change the capillary pipe. At the same time, the filter-dryer is replaced. After restoring the integrity of the system, the refrigerator is vacuum and seasoned with freon.

The refrigerator does not freeze

The refrigerator does not freeze. characteristic reasons

Analysis of the repair of technology during the warranty period shows that most often the position refrigerator ceases to freeze due to malfunctions associated with electrical wiring. It is possible to burn contacts, insulation violation. Therefore, it happened that the case hits the current, we need an urgent revision of the electric part. This applies to PZR. you need to check its connection and work.

There are frequent cases when the refrigerator begins to work with a violation of the cycle. If the light in the chamber burns and the temperature rises, the compressor is rarely turned on and briefly, it is necessary to check the thermostat. There are breakdowns of the motor-compressor in both parts of it. Can jam the piston, break a crooked. With prolonged load, one of the windings of the motor can burn out if thermal protection in the starting relay does not work.

If the device has worked out the warranty period without breakdowns, in the future it is possible to clog the capillary tube and the dehair filter. But if the refrigerant is used, the probability of traffic jams in the capillar is reduced. Finds a breakdown and eliminates only a specialist.

For the user, it is important to notice when the refrigerator of the position has become very freezing or vice versa, the temperature rises. There is only one reason. a failure in the regulation system, refusal of temperature sensors. As a result, the entire heat voltage system is subjected to loads, which will lead to a breakdown of the next node. The reasons that require the call of a specialist for the diagnosis and repair of the HOSIS refrigerator:

  • The upper chamber does not freeze;
  • The freezer does not freeze;
  • The compressor does not turn off or turns on for a very short time;
  • Strong icing of the walls of the chambers, ice below under the boxes, when the drain hole is clean.

It is not always possible to independently clean the drain pipe for condensate, it can be frozen. If water accumulates under the cabinet, perhaps the water tray above the compressor is installed obliquely, or the tube is lowered in addition to the capacity.

What to do if the refrigerator is not frost does not freeze

Modern models of two.chamber refrigerators of the Hannfrost series have air cooling of both cameras. Cold removal is carried out by a stream of air, the pressure is created by a fan. The fan installed behind the wall of the freezer drives the air between the evaporative tubes. The cold does not enter the freezer if the fan or a warm evaporator stops. This happens if the compressor or not the refrigerant in the circuit costs. To establish why the stirre of the item has stopped freezing, the device can repair, maybe a master.

The No Frost system, in addition to the fan, includes the tickling system and the air duct. In breaks when the compressor does not work, the timer includes the heater. Accumulated frost turns into water and merges into a pipe. If the rewinding is disturbed, the evaporator will freeze, the fan will stop. Cold air enters the upper chamber through the damper in the duct. With a breakdown of this mechanism, in the main cabinet, the temperature will increase.

The upper chamber of the refrigerator is not freezing

Most often, the upper camera does not freeze in the refrigerators. The reasons are ordinary, characteristic of all refrigerators:

  • the temperature control controller is incorrectly set;
  • faulty thermostat;
  • an influx of fresh air due to the impaired seal or skew of the door;
  • not enough in the refrigerant circuit;
  • Disrupted operating conditions of the device.

Electromechanical models of domestic production refrigerators allow you to repair seals, doors, replace thermostat and lighting on your own. A specialist is needed if there are questions about the operation of the compressor, electric part and the circuit of the heat discharge.

The device of a typical refrigerator

The compressor is overtaken by its pressure freon (cooling agent) into the condenser node. There the gaseous refrigerant condenses into the liquid fraction. This process is accompanied by heat release, which is discharged through the rear panel of the refrigerator.

Liquefied freon is supplied to the system of thin tubes, after which it again takes a gaseous state, and when it is in the evaporative block, it boils. Evaporator and generates cold. Freon completes its circulation, returning to the compressor.

The cold that has arisen primarily enters the freezer, and from it is already supplied to the refrigerator. forcibly or naturally. This gives the freezer the ability to maintain cold temperature even when the aggregate elements are damaged.

In two.compressor refrigerators, one compressor serves the freezer, and the second. refrigerator. This is convenient in that, if desired, you can turn off some of the cameras and use only one

As soon as the lack of cold in the cooling compartment is noticed with a proper freezer chamber, you need to try to analyze the situation yourself.

User actions in case of suspicion of a malfunction of the unit should be as follows:

  • to establish by observation which cold does not get into the cameras;
  • Clarify whether there are any heat sources near the refrigerator, for example, heating batteries, heaters, kitchen slabs, etc. D.;
  • Determine whether the rubber door sealing gasket is valid, whether there are objects (pieces of food, crumbs, etc. P.), preventing the tight closure of the door.

It will also be useful to inspect the rear surface of the refrigerator for the presence of mechanical damage, and all nodes and systems for rye, oxidation.

Reasons for the lack of cold, their elimination

With the good operation of the freezer compartment, the reasons for the breakdown of the refrigerator can be very different. Both an ordinary temporary absence of electricity on the network, and a serious breakdown of the compressor, which almost always leads to a rather expensive replacement.

The simplest malfunctions of the unit

Before starting an analysis of the problem, you should make sure that the unit is connected to the electrical network, the serviceability of wires, extension cords, sockets, and in good supply of electricity to the room.

One of the perpetrators is a loose closure of the camera door for the user’s oversight. There is a constant intake of warm air from her from the room.

Cold may be absent due to the long period of the refrigerator functioning without planned defronts. It is worth turning off the unit, thoroughly defrost it and turn it on again in a day.

For the correct defrosting of the refrigerator, you need to turn it off from the network, open it wide, extract all the contents and wait for it to completely defrost. It is prohibited to accelerate this process in any way. Talus water is collected in containers and utilized

There are situations when the freezer compartment is filled with products too tightly, so that free space is practically absent. According to the rules of operation, this is undesirable, since the space for air circulation should still be.

When the products for freezing are close to each other and is tightly tamped, the entire power of the compressor goes to freeze its huge volume, and there are not enough cold for the rest of the cold departments.

It is better to freeze products in small parts. When freezing, it is not recommended to fill the freezer “to capacity”. this is fraught with compressor breakdown

The refrigerator itself can be incorrectly installed. close to the wall, when heat cannot be fully allocated, or near the heating devices. temperature detectors are lost. They give the compressor signals about the strengthening of its power, but cooling in the refrigerating chamber does not occur, because it turns into heat along the way.

This failure mostly happens if the freezer is installed inside the refrigerator. Such a problem is eliminated by a full.fledged prolonged defrosting of the entire unit, installed it away from heating sources, turning on on a standard, and not enhanced mode.

It is forbidden to have a refrigerator close to heat sources. This not only disables it, but also significantly increases the money costs for electricity

breakdowns in conducting systems

In order to understand the causes of more complex breakdowns, you need to know how the refrigerator works and how the refrigerator works. Only then will the origin of the malfunctions be clear. As a result, the right ways to solve the problem will be able to be found.

pozis, refrigerator, work

Capillary system. The culprit of the breakdown can serve as a mash in the capillary system due to the entry into the pipeline of foreign substances-moisture, oils, litter from the filter and other things that have become unusable and other.

Because of the blockage, the cooler does not reach the end-everything is in order with freezing, there is even ice form. And the products in the second cell do not cool. in this department heat.

Signs of capillaries blockage can be confused with a breakdown of a different nature. a malfunction in the work of the evaporator. To accurately find out the cause of the problem, analyze the temperature of the discharge system on the “condenser-compressor” section. If the heating there is insignificant or partial, and the cooling is fast, then the reason is in the block of capillaries.

However, there is an opportunity to correct the situation on their own: if the margin is simple, then the light tapping of the pipeline will move the cork from the place and the path for Freon will be released.

If tapping does not help, you need to contact a master who will professionally clean the tubes, install a new clean filter, replace the freon, remove unnecessary air from the evaporator.

First, the temperature between the compressor and the capacitor is measured, and then the decision is made to replace the capillary tube or on the possibility of its repair

Drainage system. A drainage system in refrigerators with a crying wall can clog. If one does not clean it for a long time, it may appear in it, which do not completely pass the melt water, it accumulates at the bottom of the camera and flows out.

Over time, the plastic cracks, and the water flows into the gaps and oxidizes the metal parts of the device, corrosion corrodes them, and the refrigerant begins to flow out. Clean the drainage system using a conventional pharmacy rubber pear. It is filled with hot water and poured into the canal with a sharp movement under the greatest pressure.

If necessary, this is repeated several times until the system is completely cleaned. Dirty merged water from a special tray after the procedure should be removed.

Refrigerators are produced with a small ruff in a drain hole. It is designed to regularly clean the entrance to the drainage system. The cleaner it is, the less chance to get a large blockage of the system

Another device for cleaning the drainage system can be a bicycle/car manual pump. If these devices are not available, or the blockage has settled very firmly, a long wire/wire will help.

The tip of the wire is bent into the loop and with twisting movements is inserted into the drain hole, while handing it back and forth. The duration of the procedure is about three minutes. You can combine two methods. cleaning with wire with a strait water.

You can check the result of efforts by testing the system. A little water is poured into the drainage tube and the drain rate is noticed in a natural way. If it does not leave, the cleaning procedure is repeated.

Refrigerator device

It is not so complicated: the working compressor creates pressure and pumps the refrigerant into the condenser node. There Freon becomes liquid. The process goes with the release of heat, which is discharged through the back panel.

Liquefied gas is supplied to the capillaries system. There he again becomes gaseous, and then boils in the evaporative block, taking the heat from the refrigerator. The gas is cooled in the capacitor, returns to the liquid phase. After that, the cycle is repeated.

Two.chamber refrigerators sometimes have 2 compressors. They perform work independently of each other. One provides the work of the freezer, and the other. the cooling of the upper part.

What to do if the freezer works, but the refrigerator is not. the action plan

Before you call the service center, look for the cause of the malfunction yourself.

First of all, make sure the refrigerator is correctly connected, and the cable and the outlet are working. Frequent cause of the problem is a long absence of defrosting or a loose door.

If you decide that the upper chamber of the refrigerator has broken, measure the temperature inside. Take a regular thermometer and put it on a dry plate. After 10 minutes, take the readings. Inside the refrigerator compartment, the thermometer should show 2-12 o with above zero.

See if the refrigerator is installed correctly. Are there a nearby heat sources. electrical heating devices, central heating batteries. The permissible distance between the side surface and the wall (furniture) is at least 5-10 cm.

  • Check the thermostat. Maybe you accidentally installed it on a high value.
  • Inspect the back wall for rust.
  • Make sure that you have not accidentally turned on the defrosting mode.
  • Put the refrigerator from the wall and evaluate the condition of the motor. If it is heated, thermal protection may turn on.
  • Make sure the door closes freely, and nothing prevents her from.
  • Check the condition of the sealing rubber.

Make sure the case is intact. Its damage causes the destruction of the thermo.insulating layer and the displacement of the temperature regime.

Diagnosis of the refrigerator

Having completed all points, proceed to independent diagnostics:

  • Listen to the engine, whether it makes an unusual noise or clicks.
  • Remember if there was a sharp load by a large number of products at the same time. In this case, the refrigerator simply did not have time to cool them.
  • Make sure there is no smell of Gary. If it appears, quickly turn off the equipment from the network.
  • Check the cable and contacts. This will require a multimeter.
  • See if the ice has accumulated on the back wall.
  • Disconnect the power and inspect the layer of the insulator on the switching cables.

Diagnosis is simple. To do this, you need to know where the main parts are located, and then check their performance. With complex breakdowns, I advise you to contact specialists.

I collected in the table the main malfunctions of two.chamber refrigerators and ways to correct them. Use it as a cheat sheet.

Defect Repair
Thermoregulator in the position of weak cooling Adjust manually
Too small distance from the wall to the back wall Push away by 15-20 cm
The refrigerator is located close to a gas or electric stove Provide the interval of at least 20 cm
Direct sunlight falls on the case Eliminate
Refrigerant leak Find and eliminate the reason, download
Blocking in a capillary tube Clean
The thermostat is faulty Put a new one
The start.up relay broke Replace
Zasor of a drainage cartridge Change, season with freon
The settings of the control nodes were lost Reconfigure

Important: carry out all the manipulations when the device is disconnected from the electrical network!

Fix it yourself or call the master?

Small repair consists in replacing the light bulb, adjusting the handle or replacing sealing rubber on the door. In the presence of skills, disassemble and replace individual details. But with serious malfunctions, it’s better not to contact.

Start should start by measuring voltage in the network. It should strictly correspond to 220 in. Other values ​​will lead to the refusal of the refrigerator.

  • Freon leaks occurred;
  • The smell of burning plastic emanates from the unit;
  • The refrigerator twitches and periodically turns off;
  • The compressor, thermostat or launcher relay broke.

If the problem is in electricity or mechanics, then it is easy to eliminate it. To replace complex elements will have to call the master.

TOP 10 basic faults

Refrigeration equipment is a technique without which it is hard to imagine life. In the event of any of the listed malfunctions, it is worth immediately repairing the breakdown or contacting a professional.

This article is universal, suitable for one-two-chamber, three-chamber models of foreign and production: HotPoint Ariston (Hotpoint Ariston), Ardo (Ardo), Beko (Beko), Bosch (Bosch), Candy (Kandy), Daewoo (Daewoo), Electrolux ( Electrolux), Gorenje (Gorenje), Haier, (Hayer), Hansa (Hansa), Hitachi (Hitachi), Indesit (Indesit), Liebherr (Liebherr), LG (Elji), Nord (Nord), Polair (Polar), PoZis (POSIS), SHARP (Sharp), Shivaki (Shivaki), Siemens (Siemens), Snaige (Snate), Stinol (Stinol), Samsung (Samsung), Toshiba (Toshiba), Vestel (Vestel), Vestfrost (Westphrost), Whirlpool (Whirlpool), Zanussi (Zanussi), Elenberg (Elenaberg), Biryuis, Yuryuzan, Atlanta, Oka Sviyag, Ocean, Minsk.

Does not turn on

The refrigerator can not turn on for several reasons:

  • First of all, it is worth checking the voltage in the network. It happens that the voltage jump occurs and knocks out the plugs, the RCD or the machine is turned off in the distribution brush. To make sure that there is electricity, connect another equipment, a hair dryer or vacuum cleaner to the outlet.
  • It is also recommended to inspect the network cable and fork. if they are damaged (colorful veins, bare wires, traces of animal teeth), you need to replace the wire yourself or consult an electrician.
  • button on / shutdown does not work (sinks, jerks or shorts);
  • The thermostat has broken-the module launches the motor in the compressor when the air temperature inside the chamber increases above 3-12 degrees;
  • Compressor defects are the most expensive repairs, since in most cases the part should be replaced in the collection.
  • If the technique turns on, it works for a few seconds, and then the click is heard and it turns off, the reason may be a breakdown of the starting relay.

It flows

The reasons why the refrigerator could leak with the formation of a puddle on the floor, several.

  • Loosely covered doors or a seal worn out. Warm air enters the gap, so condensate forms and flows to the floor.
  • The drainage system of the freezer or main compartment clogged. Pieces of products could get into it, excess moisture in this case would accumulate inside the chamber and flow out.
  • Dragon of drainage drain. The problem usually occurs after the equipment moves.
  • The heater of the evaporator failed (only in equipment with the No Frost system).
  • The container for collecting and evaporating condensate burst.

Hard freezing and there is a hoarfrost

If a snow fur coat appears on the walls of the freezer, and the refrigerator is not equipped with the No Frost system, this may indicate that it has not been defrosted for a long time.

Among other causes of the defect:

  • overloading equipment with products;
  • the failure of the compressor;
  • breakdown of a thermostat or sensor sensor of temperature;
  • pollution of the capillary tube, it needs washing and refueling by a refrigerant;
  • Freon leak.

Does not freeze and does not cool

If the refrigerator has stopped freezing or cooling, you can look for the cause in several technical nodes.

  • Incorrectly set temperature on the thermostat. You can eliminate yourself by adjusting the parameters.
  • Breakdown of the thermostat, the part must be replaced.
  • In the condenser, pollution accumulated, which is why the passing Freon does not cool the camera to the desired indicators.
  • Examination of the seal on the doors. Cooling air comes out of the chamber, and warm accumulates inside.
  • Refrigerant leakage occurs due to damage to the capillary system or tube.
  • The failure of the compressor. the part must be replaced.
  • The room may be too hot, which also leads to such a breakdown. Technology is prohibited to install near heat sources.

The motor works without stopping

Under normal conditions, the refrigerator continues continuously for 12-20 minutes, then turns off. If the technique works for a long time without interruptions, the compressor can soon break or burn the starter winding from overheating.

  • Loosely adjacent doors due to the skew of the loop or wear, holes or cracks in the sealing gum. It is often accompanied by a squeak or other sound notification that the door is not closed to the end;
  • The feature of express-carrotes is enabled. It is impossible to leave for a long time in such modes, since the equipment works for wear;
  • the failure of the thermal attemptor or thermostat;
  • incorrect operation of the main control module, it must be re.reflected or replaced;
  • Freon leak. leaks and damage in the circuit are eliminated, refueling is carried out;
  • The broken compressor does not pump the pressure in the system and the electric motor operates idle.

Often the refrigerator works almost without stopping if the room is too high in the room.

Holy noisy

The refrigerator can make a loud noise if it is incorrectly installed. During installation, it is worth making sure that the equipment stands on a solid flat surface. If the requirements are respected, you need to look for a malfunction.

  • fan breakdown or difficulty in its operation due to the thick layer of ice on the walls;
  • Incorrect installation of the compressor. during his work, it is in contact with the tubes, which causes rattling;
  • The weakening of compressor fasteners.

information about the sources of noise and elimination methods can be found from this article.

The light does not burn

If the light does not burn in a working refrigerator, this may indicate the following faults.

  • Hoering or magnetic switch has broken (light in the chamber may blink). When the door is opened, the network closes, light appears inside the camera.
  • A light bulb burned out.
  • Cartridge failed or contacts dispersed.

Simple repair

In some cases, you can return household equipment to the working condition after a simple repair of it with your own hands.

Change the bulbs

Replacing a blown bulb with a similar new one. simple work for a professional. You can familiarize yourself with the instructions in the article, it describes in detail the procedure for removing the ceiling, how to correctly unscrew the remains of the basement and other nuances.

We clean the drainage system

During operation, pollution appears in the refrigerator drainage system. small pieces of food, fat, dust. So that there is no moisture under the compartment for vegetables or under the bottom, it is worth regularly cleaning the drainage tube.

Replace the sealing gum

The wear of the seal appears due to inaccurate operation, leads to a change in the temperature regime inside the compartments. You can find out about the replacement of this component from the article.

We eliminate the rattle of the compressor

The noise arising during the refrigerator can be the result of the incorrect operation of the compressor. The master needs to inspect the equipment and identify whether the engine with tubes and other mechanisms is in contact.

We outweigh and align the doors

For the convenience of operation, modern kitchen appliances are equipped with the possibility of outbringing the door. Such repairs will help professionals, details can be found out from this article.

We check the correct installation

The refrigerator should stand on a hard and flat surface. To make sure that the requirement is observed, you can use the construction level. The technique should not stagger and be distorted on one side. In modern models, the legs are characterized by the possibility of regulation in height, so you can eliminate unevenness. Read more here.

If there is a lot of ice in the freezer

The ice in the freezer may indicate that it is necessary to temporarily turn off the equipment, conduct defrosting, and then thoroughly wash the unit. You can learn about how such a simple repair is carried out from this article.

The main camera does not cool, and the freezer works. what to check

When the upper chamber does not cool, you may encounter two problems: damaged products or high wear of the main parts of the refrigerator. Когда что-то одно в системе не работает, на остальные узлы идет повышенная нагрузка. Therefore, if you notice that the camera does not cool, but warm, it is worth taking urgent repair measures.

To exclude a breakdown, first check the following points:

  • How tightly the door closes. Most likely, the camera is not closed enough. Change the location of the products on the shelves, arrange containers and pots, and the temperature will soon be included in normal mode. If you notice the ice or a snowy “fur coat” on the wall, carry out complete thawing. after turning on, the work of the equipment should normalize.
  • Fan work. Often in two.compressor models of the fan blades can freeze, which blocks its rotation. As a result, the camera works, but does not cool, because the cold is not pumped out. To detect a fan breakdown, listen to the operation of the technique. usually the coolery work of the cooler is heard. If the fan is silent or on the contrary, it creaks strongly due to the fact that the blades are beating on the ice, it is worth thinking about defrosting for 10 hours.

Important! Defrost the equipment for at least 10 hours. less time will not be enough to complete ice thawing, and the problem will not be solved.

If, after checking the door and the fan, it turned out that everything was in order, or defrosting did not help, then the qualified help of the master is required. Disconnect the refrigerator from the network and contact the service or try to independently find out the cause of the breakdown.

Pozis Ремонт не Ремонт

Why the camera does not work in the refrigerator

If the factors listed above are excluded, the reason for the lack of cold in the main compartment lies in the breakdown. If you have a refrigerator of the brand “Samsung”, “Indesit”, “Stinol”, “Shivaki” or any other, a table with possible breakdowns will come to your aid.

Such symptoms also indicate a refrigerant leak, only in the area of ​​the steel circuit of the freezer compartment (in models with the lower arrangement of the freezer).

Blocks of the drainage system provoke flowing excess water to the front of the freezer compartment. In this area, a steel circuit passes behind the plastic panel, which prevents the appearance of condensate on the sealant. Plastic in view of its porous structure passes the water inward, which is why the steel part rusts, cracks appear on it, and the freon disappears.

Not every malfunction has “symptoms” by which it can be detected. The failure of the camera can also provoke such malfunctions:

  • Damage to the launch relay. It is commonly caused by the natural wear of the part or the voltage jump on the network. The details of the part are required.
  • Clogging of the capillary system or blockage of the filter-dryer. In the system, oil circulates, sometimes it causes a blockage of a capillary tube, which interferes with normal circulation of freon. If the master confirms the problem, oil and freon are changing.
  • Failure of the air thermal sensor of the refrigerator or evaporator sensor (for electronic models). In this case, the control board does not receive the temperature signals in the chamber, therefore the compressor does not start, the temperature grows. We need to replace the failed node.
  • Temperature breakdown (for mechanical models). The situation is similar-the compressor does not start due to incorrect temperature indications. Replacing the part will solve the problem.

If you were not able to independently identify the breakdown and find out why the refrigerator does not cool, entrust this task to a good specialist so that your refrigerator has worked for many more years.

Author

Laidred

| Denial of responsibility | Contacts |RSS