Home Article Is it possible to put a boiler below the tap
Article

Is it possible to put a boiler below the tap

How Do You Install a QETTLE Boiling Water Tap? Watch Step by Step Guide to Getting it Right!

Installation of an electric water heater (boiler)

After a long procedure for choosing a suitable model, a crucial moment of installation of the water heater occurs and connect to the mains. If you do not know how to install an accumulative electric boiler, then it is better to contact a specialist. The service will cost within 100. If the house has an old electrical appliance, and it must be replaced, you will have to pay extra for dismantling. Those who want to save home budget can use the instructions on how to install and connect a water heater without outside help in a couple of hours.

If it is decided to install a boiler with your own hands, then you need to clearly know how to do it. The errors during installation will lead to partition of the wiring, flooding of housing, as well as the failure of the device. Consider the basic rules for installing a water heater:

  • First you need to choose the optimal location of the device. A boiler is usually installed in the bathroom, toilet or in the kitchen. They provide free access to the electrical appliance.
  • The wall or any other support for the boiler should withstand double weight, for example, with a capacity of 80 l, the load indicator is 160 kg.
  • The old wiring is subject to mandatory replacement, otherwise it simply cannot withstand the load.
  • Warring from metallic pipes of a ten.year ago will have to change the same way.

Other rules, and the nuances of the installation will be stipulated in the installation instructions.

The best place for mounting

Many place a boiler in the bathroom over the toilet or other side surface. Such a choice may entail a decrease in space in the room, complicates the functionality of the room. Nevertheless, the best option for attaching the device will be a place over the bathroom itself or near the shower cabin.

General installation tips.

As you can see, the connection of a flow water heater is a simple task that requires maximum concentration of attention. If you incorrectly attach the coupling or slightly tighten it, then the breakdown is inevitable, because of this, the service life can also significantly decrease.

How to install a flowing ignorant water heater

Select the installation site

Underwear proto, as a rule, can provide only one point of water clearance, so the issue of choosing a place is not worth. The device is installed instead of the mixer on the washbasin in the bathroom or in the kitchen, as well as next to the crane in the shower.

Fasten the water heater

The device in the tap form factor is most easily mounted. To do this, redraw the water on the mixer and remove flexible eyeliners from it. Unscrew the mounting bracket of the crane and remove it from the sink.

Collect the water heater according to the instructions: attach the spout, tighten the input fitting and insert into the hole in the sink. Probably a mounting nut and tighten it to fix the proton.

possible, boiler

Wall models will have to be attached to dowels or screws depending on the type of wall. Using a template or measuring the distance between the brackets, make markings and drill holes. Fasten the water heater with dowels or screws.

What is Air Lock?

Connect to the water supply

Everything is simple here too. The connection is reduced to the accession of a flexible eyeliner, which you removed from the mixer, to the fittings of the water heater. Install a rubber gasket under the unit nut and wrap it first by hand, and then with a slight effort with the key.

The wall setting can be powered from the same flexible eyeliner or from the shower. To do this, unscrew the watering can from the hose and connect the released end to the input of the water heater.

An important point! After the water heater there should not be any locking reinforcement. Water is overlapped exclusively by the proto or crane itself, to which it is connected. Otherwise, due to the lack of duct, the heater may overheat and fail.

Connect to the mains

Compact non.pressure models usually have a finished wire with a fork, so the connection boils down to the fact that you need to insert a fork into a socket with ground. Since the water heater refers to powerful devices, it is prohibited to connect it through tees and extension cords. Due to the large current, the contacts in them can overheat, melt and cause a fire.

Make a trial launch

Cross the tap on a hot water riser. Open the mixer and let water through the device. Wait a few seconds until a flat stream goes. Put the device into heating mode by turning the lever or by pressing the button. Check that the water heats up.

Why a boiler

I chose different models of heaters for the apartment for a long time. There is no gas in the apartment, so it was necessary to choose an electric heater. I really wanted hot water to flow constantly and under normal pressure. Having studied the characteristics of the models proposed on the market and types of water heater, I came to the conclusion that I need an 18 kW.high electric heater for 18 kW. In addition, he is 3 phases.

Since it is not possible to lead another phase into the apartment (no one would give me permission), I had to look at the weaker heaters.

Among the running and relatively low.power heating I was embarrassed by the little pressure of the heated water. And so I had to return to the version of the accumulative water heater, to the boiler. I chose the largest model that got into my toilet. Ariston ABS VLS PW 50 Boiler.

The pluses that I saw this relatively acceptable volume of hot water with normal pressure.

Norms and requirements of the installation of a gas column

Before connecting the water heater, make sure that all the documents necessary for installation are collected. The registration procedure is as follows:

Representatives of the Contractor will make a insert into the highway, install the counter, hang and connect the water heater and connect. At the request of the customer, the installation can be performed by any organization that has an appropriate permit and a license to carry out work of increased danger.

Premises for installing a column

Gas water heaters potentially dangerous equipment. The premises in which it is planned to install a boiler must comply with fire safety requirements, the rules described in SNiP and SP, as well as in the recommendations of manufacturers.

The main criteria and requirements for the room used for the boiler room:

As a boiler room, it is allowed to use any non.residential room that meets the described requirements. It is not allowed to connect a boiler in living rooms: kitchens-studios, living rooms. In rooms with high humidity (bathroom, toilet), installation is strictly prohibited.

Technical requirements for premises for the installation of flowing gas and storage water heaters may vary depending on the region. Before you start paperwork, you should ask what norms apply in a specific area.

Regulating documents stipulate the installation height and type of walls and partitions, on which the installation of gas water heaters is allowed. Gaps and safe distances between the boiler and other gas.consuming equipment are indicated.

Installation of a combustion product withdrawal system

Gas speakers should be connected to a separate chimney channel, with natural circulation. Forced hood is prohibited. When passing through the floor slabs and the roof, fire breaks are provided. General requirements:

The technical conditions for the installation of a turbocharged blessing gas column provide for connection to a vertical or horizontal coaxial pipe. In the case of a horizontal output of the smoke removal system, SP 60 is taken into account.13330 (SNiP 41-01-2003) with a description of the necessary breaks:

Installation features: what to pay attention to when hanging

An important question in the process of installing a boiler is a definition of a place that is as suitable as possible from a technical and aesthetic point of view. So, where you can install a boiler?

  • The device should not affect low temperatures T.e. The boiler is installed indoors;
  • The distance between the water heater and the water flow point should be minimal;
  • The boiler should be placed next to the pipes of hot and cold water to organize its connection to the system;
  • To improve access to the device to perform maintenance work. it is necessary to leave free space around it;
  • the wall on which the installation should be carried.
possible, boiler

It should be remembered that the water heater will be a rather heavy object, and the wall should withstand weight. And the internal walls forming partitions between the rooms can be made of materials that are not designed for a weight of about 100 kg. Now, knowing where to place the boiler, it is worth dwelling on some features.

A boiler device in an apartment building. Electric boilers

This is the most common type of DHW devices, most often used in apartments and small private houses.

The reason for this popularity is the relatively low cost and ease of installation, which does not require any permits.

The devices are quite reliable in operation and satisfy most user requirements. To understand the principle of operation of the water heater, consider its device shown in the figure:

The unit is a tank, usually a round or oval shape, enclosed in a layer of thermal insulation material (usually polyurethane foam) covered with a decorative casing. The container itself can be made of such materials:

The electric heating element placed in the lower part of the tank heats the water to the temperature limited by the thermostat. Its maximum value, accepted in all electric boilers, is 75 ºС.

While there is no water clearance, the device of the electric boiler provides for maintaining the installed temperature in automatic switching mode for and off the heater.

The latter has additional protection against overheating and in an abnormal situation will automatically turn off when the water temperature reaches 85 ºС.

Note. The optimal operating mode for the boiler is heating up to 55 ºС. In this mode, the device provides the right amount of water for the hot water and at the same time saves electricity.

Unfortunately, often the accumulative water heater works at maximum power due to the fact that in the winter, too cold water comes from the water supply and the heater in economical mode does not have time to warm it up.

Water discharge occurs through the tube brought into the upper zone of the tank, where the water is the hottest. At the same time, cold water is supplied to the lower part of the boiler, where the heater is installed.

possible, boiler

To protect steel tanks from electrochemical corrosion, the water heater device includes a magnesium anode.

Over time, it is destroyed, and therefore requires replacement about 1 time in 2-3 years.

Installation of a water heater

You have already purchased a water heater and if the issue of its installation remains open, then this article is for you. Based on it, you can independently install a water heater, or control the operation of installers involved in the installation.

First of all, I consider it necessary to inform that the installation of a storage water heater should be carried out by a qualified specialist in accordance with applicable rules and sanitary standards. If you are not sure of the ability to independently install a heating device, then we recommend that you use the services of a specialist.

This device is designed for installation inside buildings, in household and utility rooms and is designed to heat the water below the boiling point, with the possibility of using hot water at several points (bath, kitchen, toilet) and further maintaining a given temperature in automatic mode.

The heating time of water depends on the volume of the water heater and the power of the heating element.

The main elements of the water heater are:

-Thermal insulation providing minimal heat loss even with a disconnected water heater.

-Temperature controller, allowing you to set the desired water heating temperature.

-The thermostat that monitors the set temperature using the control control of the heating element.

-The safety valve, which is installed at the entrance to the water heater and performs the functions of preventing the return of water to the water supply and protect the internal tank from excess pressure.

-Magnesium anode that provides additional protection of the internal tank from corrosion.

possible, boiler

The water heater is installed on the capital wall, using brackets and hooks (not always included in the delivery kit). It is recommended to use hooks with a diameter of at least 12 mm.

Depending on the selected model, you will need 2 or 4 such hooks.

The prepared mount should withstand the three.filled water heater.

The installation of vertical models is unacceptable. horizontally, and horizontal models. vertically.

-To reduce heat loss, the device should be installed at the minimum distance from the water.bended node (the place where water from the water heater will be used).

-For maintenance, it is necessary to provide a free space around the device at least 50 cm, and 10 cm from the ceiling.

-The installation of hooks in the wall should exclude spontaneous movement of the water heater bracket along them.

-After installation, be sure to check the reliability of the mount.

-In order to avoid damage to the property of the consumer and (or) third parties in the case of malfunctions in the hot water supply system, it is recommended to install the water heater in rooms that waterproof and drainage in the sewer, and do not place objects subject to water under the water heater subject to water.

The installation of a safety valve included in the set of delivery is a mandatory requirement.

It is forbidden to install any locking reinforcement between the safety valve and the entrance to the tank, as well as block the drain of the safety valve.

The water heater connection to the water supply system should be carried out using detachable connections.

With standard connection, the water heater works under pressure determined by pressure in the highway.

The safety valve included in the delivery set must be installed at the inlet of the cold water of the water heater. It is recommended that the safety valve be wrapped by no more than 3-4 turns, providing tightness with a fum tape, flax or other waterproofing material.

Connect the input pipe of the safety valve to the cold water line using a flexible hose. If necessary, install a shut.off valve.

Connect the pipe or hose to drain hot water to the water station to the water heater to the water heater.

For the convenience of servicing the water heater, it is recommended to install a drain-three valve between the input of the water heater and the safety valve. This tee will help drain water from the water heater without twisting the safety valve.

To facilitate the access of air into the tank, when draining water, it is recommended to install a second tee equipped with a locking tap.

In the heating mode from the drainage opening of the safety valve, water can drip water. To remove this water, a drainage hose is used, which should be laid downward down. The temperature in the area of ​​the laying of the drain hose should not drop below 0 ̊

If the water pressure in the water supply is close to the pressure of the safety valve, then a lowering gearbox should be installed before the safety valve. In order to avoid clogging of water.divided reinforcement or shower nozzles, extraneous particles and dirt should be removed from the pipes.

For some models, due to the design features, the installation of hydraulic compounds, including the installation of a safety valve, is possible only with a water heater removed by a plastic cover.

After the installation of hydraulic compounds, this cover should be installed back in place, fixing with regular screws.

In addition, it is recommended to connect the water drain hose. This hose will direct the water drained from the water heater to the sewer or other place you selected.

Connect the water heater pipes only to pipes and fittings designed for temperature,

Author

Laidred

| Denial of responsibility | Contacts |RSS