How to raise pressure in the boiler Buderus?
Parsing by brands
Immergaz | 20 |
Buderus | thirteen |
Weland | 20 |
Hermann | 25 |
Sudden drop in water pressure indicates serious problems in the operation of not only the boiler, but the entire heating system. If the manometer indicates that the pressure in the system is below one atmosphere, you should try to manually add water, opening the recharge valve.
The pressure in the boiler drops: how to raise
Nominal pressure in the system provides normal circulation of the coolant and pressure in the taps. But what if the pressure falls in a dual.circuit boiler? Why is this happening? Main reasons:
- Incorrect installation,
- The inconsistency of the boiler power to your pipeline,
- flow,
- Damage to the radiator,
- Gas supply interruptions.
Consider how to raise pressure and what to do when the boiler does not hold it.
Varieties of pressure
Why does pressure drop in the wall device? First, we will figure out what types are and how they affect the work of technology.
- Static. The greater the height, the higher the indicators. With each meter there is an increase by 0.1 bar.
- Dynamic. Forced operation of the pump creates a nominal pressure in a closed system.
- Working. Includes two of the above options.
- Excessive. It is defined by the manometer as the difference between atmospheric and fixed.
- Nominal. That which was indicated by the manufacturer in the documentation for a specific model.
- Maximum. The maximum that is allowed to avoid breakdowns and accidents.
- Pressing. Used in production when checking equipment.
In the heating circuit, indicators are measured by atmospheres. They may vary; It is important that the value does not exceed the permissible maximum and minimum thresholds. Low value is possible only when rolling the coolant into the circuit. In other cases, it should not deviate from the norm.
Pressure control in a gas boiler
All modern heating equipment is equipped with control sensors. The pressure sensor monitors normal work. In the event of a deviation from the norm, he sends a signal to the managing module, which is why the boiler is blocked. Additionally, an error code may seem on the display.
What pressure should be? The manometer helps to track values. The hinged unit “Bosch”, “Ariston”, “Navien”, Baxi, installed in the house, supports values from 1.5 to 2 atm. The fall of indicators is observed only in systems with a forced movement of the liquid (pump).

How the equipment works
Under normal conditions, the work takes place in this way:
Buderus настройки
- Sensors fix the temperature of the coolant. If an external thermostat is installed, the burner is automatically ignited and heating is performed.
- Together with the increase in temperature, pressure rises. When heated, the water expands, therefore, an expansion tank is provided for the discharge of excess coolant. The safety valve also drops excess into the sewer.
- If a failure occurs in the work, too much water is drained. As a result, pressure falls.
- As soon as the temperature reaches the installed, the boiler is turned off.
Read more about the work of the expansion tank:
- The tank consists of two parts that are divided by the diaphragm. Nitrogen is located in one cavity, excess fluid accumulates in the other.
- The coolant fills it as much as the difference in the values of the system and nitrogen.
- As soon as heating stops, the nitrogen pushes water from the cavity by deformation of the membrane.
Why water pressure fell
- The height of the hull installation, as a result, is the height and length of the pipes.
- Fluid exposure to pipes and other elements.
- The design of the main routes.
If your house has an autonomous heating, then the norms depend on:
Next, we will consider the reasons not related to the installation. If the device drops and does not gain pressure, it may be internal breakdown or external factors.
You add the coolant to the circuit, but the pressure is still low. If the batteries heat up well, the moisture evaporates quickly, so the leakage is difficult to detect. Take a dry napkin and walk at all the joints of the pipes, connections. Look, perhaps puddles accumulate under the radiators.
If the leak has not been found, use the compressor.
- Disconnect the radiators from the heating device.
- Drain the entire liquid.
- Connect the compressor to the taps.
- Book the circuit with air.
- You will hear an extraneous sound in those places where there is damage.
- For sealing, use plumbing packet or sealant.
Your radiators are built into the wall? Then contact specialists. They will check the thermal imager. You will have to open the damaged area and carry out repairs.
Incorrectly selected boiler. power does not correspond to the installed parameters of the pipeline. Therefore, the pressure is constantly falling and does not hold.
If the values fall quickly, the reason may be in the expansion tank. At the same time, you fill the coolant every week, but it becomes less and less, although there are no leaks. There is also a discharge of pressure in the mixers.
- Crush water supply valves.
- Completely drain the water from the contour.
- Open the fitting on the expansion tank (RB) and fix the numbers.
- Sour the air with a pump until all the water comes out.
- Strail the air and repeat the actions. Make sure that the arrow on the pressure gauge does not exceed 1.3 bar.
- Open the taps and pour the liquid.
If after the procedure the pressure falls and does not rise, inspect the membrane for damage. Replace if necessary.
The heat exchanger malfunction. After checking the pipes and connections of violations, no? Inspect the damage radiator. Large cluster of the scale on the tubes leads to frequent flushing reagents. The material wear out quickly from this, cracks appear.
The Bittermic Node cannot be repaired due to the design. You will need a replacement. If a tubular radiator is installed, dismantle it. Fistula can be found on green spots on the surface. Dry the device, clean the damaged place with sandpaper. After spend the adhesion with a soldering iron or burner.
Unfortunately, after the repair, the node will not last long. Therefore, sooner or later you will have to change it.
Why does the pressure in the Navien gas boiler drop
The boiler is 2 contour. batteries do not flow. checked. Nothing flows inside either.
there are two options (provided that it is definitely nowhere to flow in the heating scheme)
nothing else comes to mind. she will not evaporate so fast.
Yes, you can easily think about what to guess))))) the boiler is newly installed or worked out?-To understand the pressure (2) and without starting the boiler, look for leaks.
A breakthrough inside heat exchanger is possible. and heating water goes into hot water supply.
If you exclude the impossible (already verified), what will remain, and will be true, no matter how incredible it turns out!
How to raise working pressure in the Navien Deluxe gas boiler?
no matter the topicalstarter left or not. This can help others.
Very true.like avriant, this flows from the safety valve. t.e. когда все заливаешь/запускаешь — течи нет, а потом кудато все уходит. If the plum from the safety valve is connected to the sewer, then the discharge of water is not visible at all.
Reason: the system heats up, the pressure rises above the serial, the valve is triggered.
Treatment: 1. Read the instructions for acceptable pressure and when filling out the system do not exceed it
- adjustment of the expansion tank, internal pressure should not be higher than the pressure for which the valve is designed
- CARA replacement
If you exclude the impossible (already verified), what will remain, and will be true, no matter how incredible it turns out!
I mean that the pressure in heating can never be higher than in the water supply.And the fuse cannot shave to zero. It’s easier to call a servicemen than to guess.
But a year later, exactly the same problem appeared. The same symptoms. Now I think. What to do? There is no desire to change the heat exchanger every year. The new boiler is a little expensive.
Check the correct location of the boiler horizontally and vertical.
Check the angle of inclination of the chimney 3-5 degrees outward.
Check the pressure of the gas on the burner to the maximum.
At air temperatures below.15grad. You should open the hatch on the boiler cover
The heat exchanger burns when condensate gets on it.
Yes, the way it is, water through the heat exchanger of the mountains.The water supply leaves and the pressure drops, but this is noticeably immediately, when the mountains open the water, the pressure jumps, first, unnoticed then more. IV.IV ,
The cousin threw off the pictures of this handsome man (handsome for three years). Complains that the heat exchanger was dreaming.
What to do, it makes sense to change the heat exchanger (you can find?) or change the entire boiler?
The cousin threw off the pictures of this handsome man (handsome for three years). Complains that the heat exchanger was dreaming.
What to do, it makes sense to change the heat exchanger (you can find?) or change the entire boiler?
one.Incorrect installation of the chimney.Should be a tilt of 3-5 degrees per street.
2.Perhaps the heat exchanger is clogged.A lot of feeding.Low pressure in the system.It is necessary to rinse on time.Some kind of weak acid.For these reasons, he changed three heat exchangers in one place on these boilers in one place.But there s are torn from the bills.
This applies not only to this brand.On Thursday, for the same reason, he changed to Baxi.(15000r!)-there is a difference?
Pressure control in a gas boiler
All modern heating equipment is equipped with control sensors. The pressure sensor monitors normal work. In the event of a deviation from the norm, he sends a signal to the managing module, which is why the boiler is blocked. Additionally, an error code may seem on the display.
What pressure should be? The manometer helps to track values. Hinged unit “Bosch”, “Ariston”, “Navien”, Baxi, installed in the house, supports values from 1.5 to 2 atm. The fall of indicators is observed only in systems with a forced movement of the liquid (pump).
How to raise pressure in the boiler Celtic
In operation, the gas boiler Celtic DS 2.16, he is 5 years old already. There was a malfunction: the device works, its highest temperature of 80 degrees, but it does not raise more than 60 degrees, which may be the reason?
A gas filter and a gas reducer is clogged. He does not gnaw. As often you clean the gas filter? This unit is very good, but like at least what equipment asks for maintenance and adjustments.
Boiler Celtic 2.16, gives an error A5? What could be?
Error code A5 on a remote control is a lack of a coolant pressure in the heating system. Raise the pressure on the pressure gauge to 1.0, and your error will disappear automatically, and the boiler will work in normal mode. See more carefully: there may be a leak of the coolant in the heating system or drips from a three.way valve.
In operation, the wall boiler Celtic DS. Makes an error E4. In other words, the pressure in the system fell. You are typing, everything is fine. How he begins to work, the temperature rises to 3 points and dumps water through the emergency. Let’s say up to 2. Later he stops warming. Resting. But when the gas.gas rod begins, it again gives an error. What is it?
You have no air in your expansion tank. Turn off the device out of the outlet, close all the taps under it, drain all the water to zero. Open the lid, download the air with a pump into an extensor tank. 1 atmosphere. At the same time, clean the filter on the return. Open all the taps and run the device in normal mode.
The Celtic DS boiler is warming up to 45 degrees and the whole day does not turn off and does not heat the batteries, from time to time indicates an error A3. How can you remove this case?
It is necessary to make a technical service, clean filters, change a three.way valve, check the gas filter.
The device gives an error A6, the gas valve affects this? Or weak circulation in the system? I also wanted to ask if it was possible to install an additional circulation pump?
Error A6 denotes: no gas. The weak pressure of the gas. Strong gas pressure. The stabilizer is working malfunctioning. The gas filter is clogged. Already a gas reducer is clogged. And at the expense of an additional pump, it is better to put on a huge area of heating.
Celtic boiler gives an ace error. What does it mean? And even when hot water is turned on, it begins to growl. Replaced the pump, but it still growls soundly when hot water is turned on. How to remove problems?
If when turning on the gas boiler does a lot of noise, then this is: a lack of water in the heating system, something hit on the circulation pump blades, the heat exchanger of hot water was clogged, the main heat exchanger is clogged. AC error is a bad contact of the temperature sensor, the temperature sensor failed, the wire broke off between the temperature sensor and control unit.
In operation, the gas boiler Celtic ESR 2.16 FFCD. Cast iron radiators are installed. Pipe pipes. In the operation manual, a warning that duralumin radiators cannot be used. Is it possible to use duralumin batteries? Merchants convince that nothing will happen. If so, is it possible to put duralumin? Or you need to change everything right away?
You yourself must decide what batteries for you to put at home. The main thing to choose with the calculation of the heated room and the correctness of the installation. Put a locking reinforcement everywhere. Put additional filters and clean them on time from time to time.
Error A7 means that it is better to replace the main control unit, in other words, a fee.
Tell me how you can configure the boiler Celtic on the timer? For example, I go to work at 7 in the morning, and come at nine in the evening. It is necessary that he himself cuts at 4 hours a day.
I can give a hint one device. the external time timer. There are various types. There are electrical and mechanical. In your case, a very comfortable thing, because the boiler is programmed from 1 to 6 hours. Of which he works for 20 minutes at huge speeds and for so long he is resting. How much is necessary, you expose. But in winter cold, I do not advise you to put on a timer. In order to avoid freezing of the device in the subzero spectrum.
The malfunction of the boiler Celtic. 2012, set 2 months back. Not previously exploited. Began to demonstrate an A6 error. With repeatedly turned on / off, it lights up. Now does not burn. The torch is lit. And so three times, later gives an error. The burner is burning only half.
You have a very weak gas pressure. This is a characteristic phenomenon to start the heating season.
Goted the gas boiler Celtic Esr 2.16 FFCD is 5 years old, this year he finished working. When turning on, it begins to type the temperature within 10 seconds, achieves the maximum and disconnects. Later, the temperature begins to fall, the device is cut and again gains 10 seconds and turns off. From time to time, the temperature grows and gives out an A4 error (overheating of the thermostat), or gives an AA error (boiling water). With all this, pressure jumps. After it boils when it is turned on, it can earn and work 5 days and again everything is repeated. I tried to clean all the filters, inspected all the valves, the pressure is normal. When hot water is turned on, the temperature increases rapidly, the protection is triggered and the AA error (boiling water), with all this, the pressure grows to the limit. The pump works for heating properly. What to do?
Your main reason is not the circulation of the coolant in the heating system.
When opening hot water, the boiler is launched in the standard mode, and gives water in portions. Hot-cold, hot-cold. With all this does not give out. What can be the non?
This situation is only in this case, when the heat exchanger of hot water is clogged with a scope. I recommend putting a new heat exchanger.
Celtic DS boiler adjustments. I would like to find out whether it is possible to set the least temperature? Just a degree set at a temperature of 50, it got heated and turned off. The batteries are heated. Later, it simply turns the pump and the temperature is released to 33-34, with all this, the batteries cool down. Is it possible to set the smallest temperature at which it is cut?
You can set the temperature on your remote control: according to the temperature of the coolant or according to the hourly mode. On time mode, you set the time that you yourself want. It works on the highest mode for 20 minutes and runs into recreation mode, at the time that you put up. Varies from 1 to 6 hours. This mode is better not to use in severe frosts. It is intended in the offseason. But at the moment, remarks have appeared on sale, which also work on the temperature of the room.
The pressure in the boiler drops: how to raise. cold
Nominal pressure in the system provides normal circulation of the coolant and pressure in the taps. But what if the pressure falls in a dual.circuit boiler? Why is this happening? Main reasons:
- Incorrect installation,
- The inconsistency of the boiler power to your pipeline,
- flow,
- Damage to the radiator,
- Gas supply interruptions.
Consider how to raise pressure and what to do when the boiler does not hold it.
Varieties of pressure
Why does pressure drop in the wall device? First, we will figure out what types are and how they affect the work of technology.
- Static. The greater the height, the higher the indicators. With each meter there is an increase by 0.1 bar.
- Dynamic. Forced operation of the pump creates a nominal pressure in a closed system.
- Working. Includes two of the above options.
- Excessive. It is defined by the manometer as the difference between atmospheric and fixed.
- Nominal. That which was indicated by the manufacturer in the documentation for a specific model.
- Maximum. The maximum that is allowed to avoid breakdowns and accidents.
- Pressing. Used in production when checking equipment.
In the heating circuit, indicators are measured by atmospheres. They may vary; It is important that the value does not exceed the permissible maximum and minimum thresholds. Low value is possible only when rolling the coolant into the circuit. In other cases, it should not deviate from the norm.
Pressure control in a gas boiler
All modern heating equipment is equipped with control sensors. The pressure sensor monitors normal work. In the event of a deviation from the norm, he sends a signal to the managing module, which is why the boiler is blocked. Additionally, an error code may seem on the display.
What pressure should be? The manometer helps to track values. The hinged unit “Bosch”, “Ariston”, “Navien”, Baxi, installed in the house, supports values from 1.5 to 2 atm. The fall of indicators is observed only in systems with a forced movement of the liquid (pump).
How the equipment works
Under normal conditions, the work takes place in this way:
- Sensors fix the temperature of the coolant. If an external thermostat is installed, the burner is automatically ignited and heating is performed.
- Together with the increase in temperature, pressure rises. When heated, the water expands, therefore, an expansion tank is provided for the discharge of excess coolant. The safety valve also drops excess into the sewer.
- If a failure occurs in the work, too much water is drained. As a result, pressure falls.
- As soon as the temperature reaches the installed, the boiler is turned off.
Read more about the work of the expansion tank:
- The tank consists of two parts that are divided by the diaphragm. Nitrogen is located in one cavity, excess fluid accumulates in the other.
- The coolant fills it as much as the difference in the values of the system and nitrogen.
- As soon as heating stops, the nitrogen pushes water from the cavity by deformation of the membrane.
Why water pressure fell
- The height of the hull installation, as a result, is the height and length of the pipes.
- Fluid exposure to pipes and other elements.
- The design of the main routes.
If your house has an autonomous heating, then the norms depend on:
Next, we will consider the reasons not related to the installation. If the device drops and does not gain pressure, it may be internal breakdown or external factors.
You add the coolant to the circuit, but the pressure is still low. If the batteries heat up well, the moisture evaporates quickly, so the leakage is difficult to detect. Take a dry napkin and walk at all the joints of the pipes, connections. Look, perhaps puddles accumulate under the radiators.
If the leak has not been found, use the compressor.
BOILER KEEPS LOSING PRESSURE. WHY AND HOW TO FIX. Plumbing tips
- Disconnect the radiators from the heating device.
- Drain the entire liquid.
- Connect the compressor to the taps.
- Book the circuit with air.
- You will hear an extraneous sound in those places where there is damage.
- For sealing, use plumbing packet or sealant.
Incorrectly selected boiler. power does not correspond to the installed parameters of the pipeline. Therefore, the pressure is constantly falling and does not hold.
If the values fall quickly, the reason may be in the expansion tank. At the same time, you fill the coolant every week, but it becomes less and less, although there are no leaks. There is also a discharge of pressure in the mixers.
- Crush water supply valves.
- Completely drain the water from the contour.
- Open the fitting on the expansion tank (RB) and fix the numbers.
- Sour the air with a pump until all the water comes out.
- Strail the air and repeat the actions. Make sure that the arrow on the pressure gauge does not exceed 1.3 bar.
- Open the taps and pour the liquid.
If after the procedure the pressure falls and does not rise, inspect the membrane for damage. Replace if necessary.
The heat exchanger malfunction. After checking the pipes and connections of violations, no? Inspect the damage radiator. Large cluster of the scale on the tubes leads to frequent flushing reagents. The material wear out quickly from this, cracks appear.
The Bittermic Node cannot be repaired due to the design. You will need a replacement. If a tubular radiator is installed, dismantle it. Fistula can be found on green spots on the surface. Dry the device, clean the damaged place with sandpaper. After spend the adhesion with a soldering iron or burner.
Problems with a tap tap. With a leak, the crane leads to a constant drop in the pressure. How to add coolant to the system? Only the replacement of the part will help.
Charges of the three.way valve. In double.circuit devices, the valve serves to switch flows from heating to hot water supply. Carry out the valve, its work may interfere with the scale, garbage.
Why does the water pressure fall in the heating system?
There are four main perpetrators of pressure reduction in pipes: a heat carrier leak from the system due to depressurization, breakdown of the heating boiler or air entering the pipeline. Depressurization of the pipeline. You can notice a puddle or moisturizing the flooring at the place of damage to the pipe.
The reason for the pressure falling in the expansion tank of the double.circuit boiler or in the heating system is most often the lack of electricity. After all, the pump works from the energy source, which provides the right pressure. Another reason is leaks in the heating and water supply system.
Proper maintenance of Buderus gas boilers: how to configure and adjust, how to enable the device and fix the errors that have arisen
The popularity and high demand for Buderus gas boilers are partly based on the relatively low cost of equipment.
But the main factor that determines the preference among users is a high level of design and assembly, the traditional German quality of components, accuracy and thoroughness of development.
Most of the owners, after the acquisition of the boiler, are not ready to operate such equipment due to an outdated approach to the operation of heat engineering products.
In the minds of people, the idea that the boiler is enough to include, no additional measures will be needed.
However, complex equipment requires an understanding of the logic of developers and design features, otherwise it will not be possible to achieve high efficiency and a long service life.
How to set up a gas boiler Buderus
The main setting of Buderus boilers is made at the manufacturer. After acquisition, it is only necessary to make some adjustments necessary for the most effective operation of the unit in a given conditions.
As a rule, the installation of the working limits of gas pressure and the temperature (heating water) is required.
Gas supply parameters are set up using the adjusting screws of gas reinforcement, with the simultaneous control of the result of actions on the control panel. A U-shaped manometer is connected to the measuring fitting, with which the gas pressure limits are determined.
At this time, you need to start service mode 1.2.F (maximum performance).
Temperature setting is performed from the control panel. By pressing the “-” button, the winter mode is caused (the heating circuit is turned on).
Then click the OK button, a temperature of OV (straight line) will appear on the display after that.
Using the “” or “-” buttons, they gain the necessary values and press the “OK” button again.
The same actions are performed for installing the summer regime, only when setting up the value is pressed on the “-” button, until points appear on the display. Then the “OK” is pressed, the crossed out of the radiator will constantly burn on the display, indicating the absence of the functioning of the heating of the coolant.
How to run the device correctly
The first launch is made after attaching all pipelines:
In addition, it is necessary to connect the power supply using a special outlet with a grounding electrode.
The electronics of the boiler is very sensitive to differences or voltage surges, so it is important to protect the control board from them.
It is necessary to use a standard voltage stabilizer produced by Buderus, or similar to him (which is somewhat worse).
The boiler is launched either at the first turned on, or after a summer break.
In both cases, you must first fill the system with water. Checking with the testimony of the manometer, the system is filled up to a size of 0.8 bar. The standard of working pressure is from 1 to 2 bar, but it should be borne in mind that when heated, the volume of water will increase, which will cause the rise in pressure.
After that, the required temperature of the coolant on the control panel is set, which will cause the burner to launch and the start of the boiler work.
Before turning on, it is necessary to lower the air from the radiators using the crane of the Maevsky., Otherwise, when starting, an error will appear. It is dumped by pressing and holding the OK button, after which the attempts are repeated until a positive result is obtained.
It cannot be filled with water with a hot heat exchanger, since this can lead to the appearance of cracks and the disable of the node out of order. Before filling, you must wait for the boiler to cool, and only then fill the system.
How to turn on after disconnecting
The boiler is turned on by pressing the corresponding button. If the disconnection occurred due to external causes (lack of gas in the highway, disconnecting water or electricity), then you must first make sure that the necessary resources are restored.
In case of refusal of any nodes or parts that caused the boiler, it is necessary to eliminate the cause-replace or repair a problem node or part, restore oxidized contacts, etc.D. Otherwise, the launch of the boiler will not be made, the installation will immediately be blocked by a self.diagnosis system.
The main malfunctions
Buderus boilers design was created on the basis of the most advanced technical developments.
They are stable in work, but not yet invented from the appearance of problems. Buderus boilers are equipped with a self.diagnosis system, which is a network of sensors annexed to the most important and responsible nodes or details of the boiler.
The work of all elements in constant mode is controlled by these sensors, when any discrepancies or changes in the standard regime occur, the alphanumeric code of one or another error appears on the display. In addition, other malfunctions are possible.
Consider the most common:
- The burner is not ignited. The reasons for this may be disconnected starters of heating or control systems, refusal protection, failure of the regulator or boiler temperature limiter. It is possible to block the boiler due to problems with the equipment control equipment for smoke gases.
- The burner turns on, but immediately gives an error. Most often, the problem is in a closed gas valve, or the presence of air in the gas pipeline. In both cases, you need to open the valve and release the air.
- After the start of the burner, a signal appears about the absence of an ionization current. Typically, problems consist in the oxidation of contacts or a confused connection of electrodes “N” and “L”. It is also possible to close the electrode of ionization to the housing or breakdown of the burner machine.
- After ignition, the burner gives an error. a current of less than 1.5 mA. Here the cause may be oxidation or the appearance of soot on the ionization electrode, which should be cleaned.
- Sounds of boiling are heard from the heat exchanger. This is a sign of the appearance of a thick layer of scale, or an insufficient amount of the coolant in the system.
Why should you follow the pressure in the boiler
The work of the boiler is accompanied by changes in the pressure in the circuit, which should be kept within the established limits. This means that when the boiler is turned on, the manometer should show the minimum value of the bar, and in the process of operation the pressure cannot exceed the permissible mark. Thus, three varieties of pressure are determined:
- Dynamic pressure is the voltage of the coolant circulating in the heating circuit;
- Statistical pressure. It is measured in idle and determines the load provided by the coolant on the heating circuit;
- Maximum pressure is the limit of the permissible load at which the normal operation of the system is allowed.
If the pressure in the gas boiler is growing, then the consequence of the normal operation of the system becomes a consequence, water releases are periodically carried out through a discarding valve or from an expansion tank.
Acts in the fall of pressure
The pressure in the circuit is not always emergency drop, for example, when the network is launched from a cold state and dropping air plugs, this is allowed.
If the air is completely stray from the circuit, the coolant reached the operating temperature, and the pressure jumps, then the pressure of the pressure in the expansion tank with air will be required.
If the boiler unit and the heating circuit does not have leaks, the expansion tank and the reinforcement are in good condition, and the pressure drops, while the unit is disabled, the service representative should be invited to check the working system of the electronic control system by the boiler modes.