How to connect a single-circuit gas boiler to the boiler. Connecting a boiler to a two-circuit boiler, how this is possible

For example, you have a single boiler in your heating system and you need to make sure that this boiler still heats water for hot water.

What are the ways to heat water through the boiler?

We will consider 5 schemes, and tell you how each scheme works. Consider the advantages and disadvantages of each scheme.

Scheme of operation of the dumb intake of coolant from the boiler

You can not use a dumb water intake from the boiler! This is a very uneconomical system of DHW, if the boiler temperature is kept below 60 degrees.

Well the first temperature of the boiler can be set to 50 degrees. At this temperature, you will not be able to heat water in the boiler above 48 degrees. Secondly, the heating will be very long, because the heat transfer drops significantly if the temperature of the water and coolant is not very different. That is, for rapid heating it is necessary to use a high temperature difference. 90-60=30 degrees. Because of this for indirect coil boilers an increased temperature of the coolant is used.

There are boilers indirect heating tank in the tank. This method uses a large area of the heat exchanger at the contact (coolant-HWC).

Such boilers have a much higher heating rate than serpentine. This is achieved by increasing the contact area (coolant-HWC). And also due to the fact that the limit of heat transfer is increased. In such a boiler increases the reception of more power due to the conservation of the coolant in the boiler, which has an inertial nature of temperature preservation. Due to this goes directly to the selection of very cooled coolant from the outer tank. This process accelerates the withdrawal of heat power to heat water. In this case, you can use the work of the boiler, provided that the temperature of the boiler is 60 degrees or more. If the boiler temperature will keep 40-50 degrees, you will have a low temperature in the boiler.

I want to draw attention to the accumulation of hot water. If you’ll have in the tank heated water of 45 degrees, you will, for example, get 10 minutes to wash with normal water in the shower. If you have a temperature of 90 degrees in the boiler, you will already be able to use the shower more than 60 minutes. That is, by increasing the temperature, you increase the accumulation of hot water in the boiler at the same capacity. That is, the volume of hot water use will increase.

If you are not satisfied with the temperature change in the boiler, which varies over time and have to readjust. There are special thermostatic valves for DHW. They are called thermostatic mixing.

This scheme allows you to always get a stable outlet temperature for DHW consumption

Scheme of work Crutch method. Increase the temperature of the boiler.

According to this scheme, we just set the temperature of the boiler, for example, 80 degrees, and the heating system will come to, for example, 60 degrees. By mixing in the cooled heating medium with the return temperature, the target temperature can be reached.

I can not say how good this method is. On the one hand they say that the boiler efficiency is higher if the fluid temperature is 60-80 degrees. This is due to the fact that at these temperatures, the chemical combustion is better and the gas burns better. That is at a low temperature there is no afterburning of the gas. That is the combustible particles do not release heat energy completely. But for condensing boilers this rule of efficiency does not work. There specifically lower the temperature of the coolant to 55-45 degrees.

On the other hand, high temperatures increase the scale in heat exchangers and pipes, which in the future may lead to loss of power and failure of the boiler due to overheating. Also on steel pipes with high-temperature coolant more crusts appear. That is the steel pipes are overgrown.

What’s wrong with this scheme? It becomes bad on the background of other DHW connection schemes. Well, for example, in some boilers there is a weather-dependent control. equithermal mode. Also, when there is a need to turn off the boiler for heating and DHW remain in operation (on automatic). is problematic to do. Because there are boilers with a function of switching off the heating on the room thermostat, and the DHW function is still working.

Working scheme To buy a two-circuit ready boiler and do not use a DHW boiler

Such two-circuit boiler has an additional heat exchanger for DHW inside the boiler. That is the first-main heat exchanger is to transfer heat from the burning gas to the heat carrier.

Electric Boilers and Components to hook them up.

Cold water passes through a plate heat exchanger under water supply pressure. There is a flow sensor on the water supply line of the DHW. The flow sensor triggers the Action Cascade: Switches to redirect the flow towards the plate heat exchanger, and increases the temperature of the coolant by increasing the gas in the heater. That is, during the preparation of DHW heating circuit is turned off. And the movement of coolant through the radiators and underfloor heating is turned off. During DHW, the coolant inside the boiler begins to circulate water through the DHW heat exchanger.

connect, electric, boiler, single

What does two-circuit boiler with insulated circuits mean? This is when the water circuit and the heating circuit do not interact by fluid. That is, fluids do not mix and fluids do not transfer pressure. Only the temperature from one liquid to the other liquid is transferred.

Water passing through the plate heat exchanger quickly heats up usually to a maximum of 60 degrees. This temperature in some boilers is regulated only to a threshold of 60 degrees. That is, a temperature above 60 degrees is not possible. This temperature is usually programmed and can not be changed. Check with the manufacturer. Also in the passport instructions for use.

Such a scheme with such a boiler is not suitable for large capacity. That is, two or three appliances (washbasin, bathtub, shower) to serve a problem. Stupidly not enough power. If you want to serve several sanitary appliances (washbasin, bathtub, shower) you must install a storage tank. It is problematic to make a storage tank for such a boiler. Next, consider the schemes with hot water storage tanks.

Pluses and minuses of indirect heating boilers

This equipment has several advantages:

  • No additional electricity costs;
  • stable hot water supply;
  • Possibility to connect different heating sources.

Along with the advantages, the indirect heating boiler has some disadvantages:

  • High enough cost, in connection with what, this equipment is not generally available;
  • If the volume is too large, it will take several hours to heat the water;
  • Requires a large amount of free space when installing.

Features

The main feature of the connection scheme of any indirect heating boiler (brand and model here can not be taken into account). is that it is deprived of its own heating unit. Water takes a thermal charge from external heating systems.

They can receive thermal energy at the expense of:

  • Burning mineral or fossil fuels;
  • electrical resistance effect;
  • Contact with the central heating system;
  • accumulation of sun rays.

Device

With any type of external thermal energy sources, the operation of the boiler is the same, with a few exceptions. And even the private innovations of individual firms, protected by patent law, do not change the essence of a long-established scheme. The portion of the heat carrier that arrives from any source goes through a coil built into the storage tank. The circulation is maintained by a pump. When it comes into close contact with the pipes or the tank where the originally colder water is, the water is heated.

Since even one joule of heat radiated outwards in vain has an extremely negative effect on the operation of the system, it is necessarily equipped with thermal protection. Polyurethane or polystyrene is usually selected as a material impervious to the outflow of heat. The arrival of new doses of cold water occurs naturally from the general water system. Each new portion passes through specially designed spigots. As soon as the cycle of movement in the coil is completed, the coolant enters the heating system of the house. for this purpose a very special branch pipe is provided.

connect, electric, boiler, single

Then certain differences begin: although most boilers are designed to supply cold water through the bottom course, there are some in which it comes through the top. In such a design, the liquid must first pass completely through the system to the lowest point. There are considerably less variations with the output of the heated medium, in almost 100% of cases it is taken from above. It is hard to find any reason why this should not be the case. After all, the upper arrangement allows you to supply hot water for as long as there is at least a small portion of it in the tank.

In order for the coil to take up as much space as possible within the body, it is usually made in the form of a spiral. When the coolant passes several cycles through this pipe, the temperature becomes equal to the heating of the liquid in the boiler itself. At the command of a special relay the special circuit supplying the pump is stopped. When the fluid cools down to the set point, the relay gives another command. to close the circuit. and heating resumes. The advantages of such a device are quite well known. All these points should be taken into account before starting work.

How to choose the right boiler with an electric boiler?

The device is used in different areas and has certain features depending on the area of use. When buying a boiler pay special attention to:

The higher this indicator, the greater the capacity of the tank should have.

It is required to accurately calculate the number of consumers and choose the right volume, for example, if we are talking about the service of three people, the tank of 100 liters will be quite enough.

When the boiler must be installed in a cottage or a private home, you can save money and buy a unit that has a tank of 80 liters.

If the device is installed in an office building or a residential home, it must have high power ratings to ensure an uninterrupted flow of hot water. When installing in a cottage or private home high power is excessive, as in these conditions there are not a large number of consumers, and there is no need to ensure an uninterrupted supply of hot liquid.

Large area of the coil will increase the rate of water heating in the tank and increase the flow of the coolant from the electric boiler. This requires an additional power consumption. If there is no need for rapid heating, then you can avoid high costs. For example, a heat exchanger with a total area of 1 square meter heats 120 liters in the tank for 30 minutes. You can also save money on the material from which the coil is made.

It must be made of durable corrosion-resistant material. The most reliable in this regard are considered to be steel and stainless steel. Particular attention should be paid to the internal coating of the device. If ceramic or vitrified clay is used as a cladding, you can not doubt the durability of the product.

Often ordinary foam rubber is used as a layer between the outer casing and the water tank.

The internal structure of the indirect heating boiler. The yellow color indicates the thermal insulation.

Such a measure makes the device less expensive, but reduces the efficiency of its work, increasing heat losses. Most of the energy intended for heating water goes nowhere, and the efficiency of the device is reduced. Modern models use polyurethane as thermal insulation.

This material is able to retain a large amount of heat and heat the outer walls of the tank, ensuring the most efficient transfer of energy from the coil to the tank.

Synopsis. Taking into account the described factors, you can choose the ideal indirect water heater with an electric boiler. Competent purchase will meet the needs of consumers in full and save some money.

Subtleties of operation

If you are looking for heating equipment for your own house or apartment, the choice rests on a single-circuit boiler and it is planned to connect the boiler, then you need to consider the following features of the boiler in a pair with this heat exchanger.

  • From the moment the boiler is turned on until it heats water for DHW will not work the heating system. Based on this trouble, it is necessary to choose a heat exchanger for hot water by the maximum time of water heating, which would be enough to exclude the freezing of heating pipes in the most extreme frost in the region of residence.
  • Boiler should be chosen according to its power, linking it to the heated area of the premises, not forgetting about the climate zone of residence, what the house is built of and whether its walls have thermal insulation. all this is important when choosing the capacity of the heating unit.
  • Determining the capacity, you can say with certainty, whether such a boiler will hold a boiler water heating system or not.

Specialists-thermal engineers believe that the boiler system can normally operate only with a boiler with a capacity of at least 24 kW. Another expert figure. the boiler takes away from the boiler up to 50% of power. These are the figures and should be guided when choosing a model of gas boiler for your home. And do not allow the situation when the boiler will be installed with a capacity of 35 kW with the calculated power consumption for heating of 25 kW, and the boiler will take 17 kW. As a result, there is a shortage of boiler capacity of 7 kW.

It is also worth mentioning the fact that in some cases you need a boiler with a large capacity, with a capacity of 200 or even 500 liters.

Such boilers are available with built-in circulation pumps for DHW.

Manufacturers of water heating devices are not stingy in the development of ultramodern models, rightly oriented to the marked interest of the population several years ago to the autonomous devices for heating and hot water supply of private homes.

Currently, there are two types of single-circuit heating devices:

Floor-type variants are more powerful, but they need a separate room in the form of an extension. Wall-mounted water heater. compact, small, installed on the wall. That is why the first of these models are widespread among owners of suburban and urban private houses, cottages and villas, and wall mounted boilers have found their admirers in urban areas.

Both boilers have a simple and clear device, attractive appearance, a high degree of safety. Make your own opinion about which of them is better, depending on the tasks facing them. Sometimes it is better to buy a single-circuit wall mounted unit with less power, but which is enough for a full heating system at home, and make a simple strapping to connect the wall construction to the column, which serves to heat cold water for their own needs (the column can be electric or gas). Binding set of hoses can be purchased separately.

Such a pair will be more reliable, especially if the heater is electric: no gas. the heater works.

Popular brands

Among the huge number of models of single-circuit gas boilers, you can identify brands of water heating devices that have proven themselves as convenient, reliable and durable units.

These include the following:

Nothing makes a person happier than a clean and comfortable warm house. But people are the creators of their own lives. Creating something for their own comfort, they, fortunately, create it for everyone around them as well. These manufacturers of gas boilers are always inventing something innovative for the new model of their products, than bribe their fans.

On how to connect a single-circuit gas boiler to a boiler of indirect heating, you can learn from the video.

Binding BCH

To coordinate operation of the boiler with the boiler and hot water system it is important to properly execute its piping. Most often, there are diagrams in the manuals for operation and maintenance of equipment. But some manufacturers are only referring to DIN 1988 “Technical Rules for the Installation of DHW. And if the strapping is done in violation of the requirements of the standard, the boiler is removed from warranty.

General Requirements

Water and heating fluid connections to the indirect exchange boiler must be quick disconnect. Pipes with connectors shall be connected with coupling nuts. To enable the BKN to be dismantled for cleaning of the accumulation tank or to replace the magnesium anode without stopping the boiler, isolation valves must be installed in the inlets.

On the heating medium side

As an example, consider the piping of the boiler connected to the system through the hydraulic separator. The BKN must have its own circulating pump. The piping should be installed in the following order (beginning with the incoming pipe in the BKH):

On the water side

The cold water inlet shall be bundled in the following order:

  • Plug connection.
  • Pressure relief valve.
  • Shut-off valve.
  • Pressure gauge connection.
  • Drainage valve.
  • Pressure reducing valve.
  • Check valve.
  • Filter.
  • Shut-off valve.

Installation of pressure reducing valve is necessary for the coordination and correct functioning of pressures in the supply line and in BKN.

line for the recirculation trimmer

If hot water is used occasionally, the part of it that is in the pipe begins to cool. When opening a valve remote from the BKN the user has to wait for the water to drain off. In order to save money, a recirculation pump is installed in the piping on the DHW side, which periodically runs water through the system.

Indirect water heater safety group

The safety group is a mandatory element of the harness of the solid fuel boiler. It prevents the heat exchanger from rupturing if the maximum allowable pressure is exceeded and removes air from the system. The same safety group must be provided in the indirect heating boiler. It can be made on a single manifold or dispersed throughout the system:

  • Manometer installed on the front wall of the boiler;
  • The discharge valve is combined with the return valve (on the cold water supply);
  • air vent should be installed at the highest point of the DHW outlet.

Connecting to the gas mains

The process of connecting the boiler to the gas mains must be performed only by qualified specialists from the gas service or other organizations licensed to perform this type of work. Self-connection to the gas main line is illegal and at best threatens the owner of the premises with a hefty fine, and at worst can lead to tragedy.

The first step in the gasification of the object. an appeal to the gas service. After submitting all necessary documents you will be developed individual specifications (TU), fulfillment of which is necessary for connection to the gas pipeline.

Once you have the TU in your hands, you can safely start looking for a certified specialist, who in accordance with the requirements of the regulatory authorities will perform the design of the gas pipeline and connect your heating boiler to it.

The gasification of the premises can be effected by underground or above-ground method. For the underground part corrosion-resistant polyethylene pipes are used, while the above-ground part is made of steel pipes that enter the room directly at the location of the gas heating boiler, at a distance of 1.2-1.5 m from the floor.

Attention! When using multiple heaters, gas supply to each of them is carried out separately. Laying of gas lines inside the premises is strictly prohibited. Taking work on the installation, you should pay special attention to the fact that the sealing of all joints should be made with soot or paint

The use of sealing tape or FUM is not allowed due to the low degree of tightness of the connection

Taking work on the installation, you should pay special attention to the fact that the sealing of all connections should be made with oakum or paint. The use of sealing tape or FUM is not allowed due to the low degree of tightness of the connection. A gas filter must be installed on the cut-off valve to protect the boiler from small debris and condensate

Connecting the gas boiler directly to the valve is recommended using steel pipes. The use of a special corrugated stainless steel hose is allowed, but pipes are still preferable, as their use does not reduce the cross-section of the gas channel

A gas filter must be installed on the cut-off valve to protect the boiler from small debris and condensate. It is recommended to connect the gas boiler directly to the shutoff valve using a steel pipe. You can use a special corrugated stainless steel hose, but pipes are still preferred, as their use does not reduce the cross-section of the gas channel.

For more information on the connection and piping of wall mounted gas boilers, see

On how properly connected the wall mounted gas boiler depends on its life, efficiency, and the safety of its owner. We hope that our brief overview of the basic steps of connecting and strapping was useful to you.

Two options for boiler connection schemes

An electric boiler is connected to the heating boiler through a three-way valve. In this connection, one pump works. the one that is installed inside the boiler or the one that is connected outside. You can also connect the boiler to the boiler via an auxiliary pump. In this connection option works switching pumps. If the boiler works for the boiler, the boiler pump turns on, if the boiler works for the heating system, then the external or internal pump of the heating boiler turns on.

Connection to a single boiler

Boiler combined with a single-circuit boiler works more efficiently, and connect it easily enough:

  • Firstly the water supply and piping to the premises are connected.
  • Switch on the electrical supply, the boiler sensor and the electric three-way valve actuator.
  • Set up and check the software control of the boiler.

When connecting a single-circuit boiler to an external boiler a special installation kit is used. It includes:

How to use the kit correctly?

To install the kit correctly, please follow the recommendations below:

  • Disconnect power to the boiler with a two-pole circuit breaker.
  • Disconnect the boiler from the heating and hot water supply.
  • Drain the water from the boiler circuit using a drain plug.
  • Remove blanking plugs from the pump group.
  • Insert a gasket in the hydraulic group.
  • Screw the supply pipe on the boiler hermetically.
  • Put the gasket on the boiler return water pipe and connect this pipe to the hydraulic group.
  • Install connectors on the return and supply pipes of the boiler.
  • Connect the two pipes to the boiler, secure them with locknuts, put seals and flat gaskets.
  • Install the three-way valve actuator.
  • Connect the actuator of the three-way valve in the boiler by means of a connector.
  • Check the correct installation of the kit and the tightness of all connections.
  • Open the cover of the heating boiler control panel.
  • Remove the safety resistor that is installed to prevent the consequences of an incorrect connection. Locate it according to the diagram.
  • Connect the water heater temperature sensor by means of a 2×0.35 mm2 cable.
  • Connect power supply to the three-way valve actuator.
  • Secure all cables and connection points.

Connect the electrical part of the boiler

  • Open the cover of the boiler control panel.
  • Remove the safety resistor that is installed to prevent the consequences of the wrong connection. Locate it according to the diagram.
  • Connect the boiler temperature sensor with 2×0.35 mm2 cable.
  • To connect the power to the three-way valve actuator.
  • Fix all cables and connection points.

How to connect the boiler to a two-circuit boiler

To connect the boiler to a dual boiler, you need to install it next to the boiler, and pipe them into one system. This method of combining two devices is called indirect water heater. Water is heated in the heat exchanger through which the water heated in the boiler circulates.

Hot water systems (boilers) usually have a built-in automation, which in connection with the boiler automation maintains the desired temperature. Modern boilers are designed to work with heating double-circuit boilers, and connected by a special installation kit.

To connect the boiler to a dual boiler is easy, but still better to entrust this operation to a specialist, because there are small features of the connection.

It does not make sense to connect the boiler to the electric boiler. this is the opinion of many professionals. Low power consumption for heating from the boiler is an absolute prerequisite for the operation of the boiler. The boiler must not overload the heating system by its connection.

If the boiler consumes more than half of the thermal energy generated by the boiler, you can not avoid the problem with heating in your home or apartment.

If you use a boiler and a gas two-circuit boiler, then a wall-mounted thermoblock with 2 circuits is enough for a small flow of hot water, and if the house has a large bath or spa-pool, you need a boiler with a boiler. To improve the operation of the heat exchanger one more circulating pump should be involved, necessarily with the automation system and the ability to control the temperature of water (or other coolant).

It is best to use a combined heating scheme in summer. from the point of view of economy. This scheme consists of a boiler, a heating element and a heat exchanger. In winter, the boiler works from the heating boiler, and in summer. from the heating element.

Types of gas boilers with indirect heating boilers

There are two versions of water heaters for DHW:

DCB is connected to the installed gas boiler. Inside it there is a heat exchanger (it can be a pipe, twisted in a spiral or the scheme “tank in the tank”).

Hot water from the heating system circulates through this heat exchanger, heating water in the boiler. The latter is connected to the cold water supply network (DHW), and from the collapsible pipe hot water flows to consumers.

Directly heated boiler can be compared with an ordinary gas heating boiler. It also has a gas burner and water tank. The burner heats the water in the tank independently of the central heating system.

Important! When installing the BKN it is necessary to estimate the power that will be used for DHW. If there are many consumers and water is used frequently, the boiler capacity may not be enough for heating, and the room temperature will be below the set temperature.

connect, electric, boiler, single

In this case it is advisable to replace the boiler with a more powerful, or use a different type of water heater.

How to Install Electric Boiler Used For Home Heating And Domestic Hot Water

Schemes of boiler connection to single boiler

There are three ways to connect the boiler to the boiler.

Direct connection of the water heater to the heating system

In this option BKN is included in the heating system, in series or in parallel with other radiators. The simplest and ineffective scheme, not recommended for use and given for reference.

Scheme of direct connection of the water-heating gas single-circuit boiler to the heating system.

If the boiler temperature is set below 60 °C, this scheme becomes even less economical, and water is heated for a very long time.

Temperature increase

Three-way valve is added to the connection scheme. a special device that switches the coolant flow when the temperature decreases in the tank of the water heater for DHW and vice versa.

That way, if the DHW water cools down, the heating is temporarily disconnected.

All power of the boiler is redirected to the DHW.

The temperature at the device in this scheme is set higher (usually 80-90 °C).

And the heating temperature is controlled by the three-way valve.

Reference! The boiler temperature must be set 5 ° C above the required water in the DHW.

Use of the thermostat in the water heater and automatics

If a thermostat is installed in BCN (a device that sends a signal when the set temperature is reached), and the boiler controller has contacts to connect the boiler thermostat, this scheme is the most preferable.

In this case the boiler electronics knows about the water temperature in the DHW system, and it decides where to direct its power: to heat water in the boiler or to heat.

Thermostat for the water heater in the heating system, with it you can know the water temperature.

Types of two-circuit gas boilers with a built-in boiler: are they necessary??

Boilers are used in conjunction with single- and double-circuit gas boilers. In the second case, the unit itself only works for heating. There are free-standing and built-in boilers.

The first are more often purchased separately, have a large capacity, suitable for single and double-circuit devices of open and closed type. Demand a complicated connection.

Built-in reservoirs. part of ready-made solutions based on two-circuit boilers. They are compact thanks to their small volume; they are supplied ex-works with advanced control systems; they can be connected easily.

Important! The volume of the free-standing boiler must be selected in proportion to the capacity of the boiler. If the tank is too large, then the water in it will not be heated to the required sanitary standard of 60 ° C. This can lead to dangerous legionella colonies.

Modern units with built-in storage tanks have a function “anti-legionella”: boiler from time to time automatically heats up to 65 ° C for 30 minutes, thereby killing harmful bacteria.

Two-circuit gas boilers with boilers differ in location, type of storage tank and its capacity.

By location: floor-standing and wall-mounted energy-independent boilers

Floor standing energy-independent boilers are of large size and high capacity. Weight of the heating device without fluid reaches 100 kg. Are equipped with built-in boilers with the volume up to 120 l and 50-500 l external mounted or floor standing boilers.

Floor standing double circuit gas boiler with a boiler of indirect heating, installed in a special room.

Often require placement in a specially equipped boiler room. Heat and supply water rapidly, but are sensitive to power surges. Create problems when connecting the recirculation system.

Wall-mounted equipment is smaller and weaker than floor-mounted equipment. Require no separate room and may be installed in kitchens and bathrooms. Are usually equipped with built-in indirect heating tanks with a capacity of 10-60 liters with constant heating of the fluid by the secondary DHW circuit.

connect, electric, boiler, single

Less often connected to stand-alone boilers of similar volume. Their heat exchangers have a small internal cross-section, which makes devices afraid of scaling and are very sensitive to water quality.

By type of boiler with an electric heater

Directly heated boiler is equipped with its own heating element that independently raises and maintains the temperature of the water. This is often a tubular electric heating element (TEN), powered by the network or by gas. Installation of the second option also requires permission of the supervisory authorities.

The DHW system may only be based on a direct heating storage tank, bypassing the connection to the boiler.

Indirect heating boilers do not have their own active heating element. In the tank with water is a coil that passes through the coolant preheated in another heater. Installed with gas equipment with capacity from 25 kW for the automatic equipment must be connected to the network.

Two-circuit gas boiler with a combined boiler, heats water in the tank due to the work of the coil.

Combined boilers have a coil, working on the indirect principle, and the heating element directly heats the water in the tank. The working element keeps the temperature at the desired level, but most of the heating is provided by the coil.

Reference! Combined heat exchangers are suitable for small single and double circuit systems. Reduce electricity consumption during the heating season by providing the necessary water heating during the entire service life.

How to connect the unit for a boiler with two circuits

Boiler to choose, determining its type, location and volume in relation to the capacity of the water heater. In storage tanks of indirect and combined type it is recommended to provide additional protection against scaling inside the coil.

Attention! It is forbidden to connect the boiler before putting the boiler into operation by the gas service.

Connection diagram

Connection scheme depends on the type of the reservoir:

The device of direct heating

The storage tank inlet connects to the cold water inlet. Output pipe. to the input of the second boiler circuit.

Cold water flows directly into the boiler, where it is heated to 60 ° C under the influence of a heating element.

From the boiler fluid goes to the boiler, losing on the way a few degrees of temperature. Passing through the second heat exchanger of the heating device, the water recovers losses and flows into the DHW system through the outlet valve of the boiler.

Indirect and combined heating

Have two additional pipe connections from the coils. They connect to the first boiler circuit. The scheme assumes that the heated coolant heating system will pass first through the coil storage tank, and only then go to the radiators.

Due to this the main gradient of the tap water heating is provided by the coil. Cold water is introduced directly into the storage tank, the heated liquid is removed to the DHW circuit of the boiler.

If the boiler is operating with an indirect heated boiler, it is recommended to change the connection diagram of the tank in case of tapping, i.e. periodical switching on and off of the burner by the boiler automatics. The boiler’s pounding indicates that the water in the storage tank is not heated to the required 60 °C.

D.H.W. circuit pipes of the water heater are plugged, water from the boiler is immediately sent to consumers. The speed of fluid heating depends solely on the capacity of the heating system, this scheme can not operate in the summer.

Indirect water heater connection diagram for a two-circuit gas boiler.

Materials and tools

Boiler internals are made of copper, steel or cast iron. Heating elements and coils are made of copper or steel. Steel walls of the tank is susceptible to corrosion, life of not more than 15 years. Cast-iron walls are twice as massive and more expensive, but work properly up to 90 years.

When constructing a boiler provide for detachable connections pipes. For this need:

  • tape measure, pencil, chalk;
  • Pen with a set of drills (for making holes for pipes, elements of wall fixtures);
  • adjustable wrenches and wrenches (ratchet models are recommended);
  • set of screwdrivers;
  • pliers;
  • wire cutters;
  • means for sealing joints (flax, FUM tape, sanitary floss);
  • sealants;
  • Stop valves, tees;
  • fittings;
  • pipes.

If there is no possibility to make detachable connections, polypropylene pipes can be welded on site.

Stage-by-stage installation and quality control

All work must be done with the equipment turned off and with the liquid removed from the system.

  • Marking the fasteners with a pencil or chalk. Drilling mounting holes.
  • Check the bearing capacity of the wall. Relevant for mounted models. On the wall to install the bracket that comes with the storage unit, load it with bags of cement or sand calculated from a double reserve.

If the wall material can withstand a load of 100 kg, you can safely hang a boiler with a capacity of up to 50 l.

  • Placement of the tank on the wall or on the floor.
  • Connection to the water mains.
  • Installation of overpressure valves in the course of water.
  • Installing the expansion tank.
  • Filling with water and checking the connections for leaks. If the water-filled system does not leak within an hour of standstill, the tightness of connections is satisfactory.
  • Plugging in the equipment, checking operation.

Two variants of boiler connection diagrams

An electric boiler is connected to the heating boiler via a three-way valve. In this connection, only one pump works. the one installed inside the boiler or the one connected outside. It is also possible to connect the boiler via an auxiliary pump. With this connection option the pumps are switched. If the boiler works for a boiler, the boiler pump turns on, if the boiler works for the heating system, then the external or internal pump of the heating boiler works.

Connection to a single-circuit boiler

Boiler in conjunction with a single boiler works more efficiently, and connect it quite simply:

  • Firstly, the water supply and distribution of water through the premises are connected.
  • The power supply is connected, the boiler sensor and the three-way valve actuator are switched.
  • Set up and check the software control of the boiler.

When connecting a single-circuit boiler to an external boiler, a special installation kit is used. This includes:

How to use the kit correctly?

For proper installation of the kit, follow these recommendations:

  • Disconnect power to the boiler with a two-pole circuit breaker.
  • Disconnect the boiler from the heating and hot water supply.
  • Drain the boiler circuit using a drain plug.
  • Remove the stopping plugs from the pump group.
  • Insert a gasket into the hydraulic group.
  • Seal the supply pipe on the boiler.
  • Put a gasket on the return water pipe of the boiler and connect this pipe to the hydraulic group.
  • Install connectors on the water return and boiler feed pipe connections.
  • Connect the two pipes to the boiler, secure them with locknuts, put seals and flat gaskets.
  • Put on three-way valve actuator.
  • Connect the actuator of the three-way valve in the boiler by means of a connector.
  • Check the correct installation of the set and tightness of all connections.
  • Open the lid of the heating boiler control panel.
  • Remove the safety resistor that is installed to prevent the consequences of wrong connection. Locate it according to the diagram.
  • Connect the water heater temperature sensor with 2×0,35 mm2 cable.
  • Connect power to three-way valve actuator.
  • Secure all cables and connection points.

Connect the electrical part of the boiler

  • Open the lid of the boiler control panel.
  • Remove the safety resistor that is installed to prevent the consequences of incorrect connection. You can find it according to the diagram.
  • To connect the boiler temperature sensor cable section 2×0.35 mm 2.
  • Connect the power to the three-way valve actuator.
  • Fix all cables and connection points.

How to connect the boiler to a two-circuit boiler

To connect the boiler to the boiler, you need to install it next to the boiler and combine them into one system. This method of combining the two devices is called an indirect water heater. Water is heated in the heat exchanger through which the water heated in the boiler circulates.

Hot water systems (boilers) usually have a built-in automation, which in connection with the boiler automation maintains the desired temperature. Modern boilers are designed to work with heating double-circuit boilers, and connected by a special installation kit.

To connect the boiler to a two-circuit boiler is not difficult, but it is still better to entrust this operation to a specialist, because there are small features of the connection.

Boiler to the electric boiler does not make sense to connect. so think many professionals. An indispensable condition for the boiler. low power consumption for heating from the boiler. Boiler must not overload the heating system by its connection.

If the boiler consumes more than half of the thermal energy produced by the boiler, you can not avoid the problem with heating the house or apartment.

If you use a boiler and a gas two-circuit boiler, then a wall-mounted thermoblock with 2 circuits is enough for a small flow of hot water, and if the house has a large bath or spa-pool, you need a boiler with a boiler. To improve the operation of the heat exchanger should engage another circulating pump, be sure to automatics and the ability to control the temperature of water (or other coolant).

In summer it is better to use the combined heating scheme. in terms of economy. This circuit consists of a boiler, a heating element, and a heat exchanger. In the winter the boiler works from the heating boiler, and in the summer from the heating element.

Proven quality pipes must be used for the installation of the boiler. I did the installation of the boiler with metal-plastic pipes of unknown manufacturer and after eight years in the bends of the pipe with hot water began to leak. And after a couple of years there was a leak in the cold water. Also it is necessary to connect the water heater to the electric socket with powerful wires. If there is no such. better to lay a separate wire from the circuit breaker.

We finally decided to get an electric boiler, and with the city water are always a problem, and the hot water I have nothing to say, most often there is none! So we bought a cool boiler, we thought my husband can install it himself, but I thought it better to let professionals do it, it will be more reliable =)