Choose from more than 3,000,000 hotels, resorts, campgrounds, hostels and aparthotels. Gather all available room options, offered by aggregators and hotel owners, in one place. Compare and conditions and choose where it’s more convenient to book.
Free shipping. Only fresh and quality products at competitive prices. High level of service and order delivery. Delivery is made in Moscow and Moscow region, St. Petersburg and Leningrad region
“Utkonos. the leader in online trading of food and related products.
Services for r.Moscow
Our innovative nano flight search will not only find you the best option for a specific date, but also suggest other dates when the flight fare can be even lower. Choose the “cheapest dates” in the special section of the site Ticket prices
Choose from more than 3 000 000 hotels, resorts, inns, hostels and apart-hotels. Collect in one place all available room options offered by aggregators and hotel owners. Compare and conditions and choose where to book the best.
Free Shipping. Only fresh and quality products for favorable prices. High level of service of assembling and delivery of orders. Delivery is made in Moscow and Moscow region, St. Petersburg and Leningrad region
“Utkonos is the leader in online shopping for groceries and related products.
Types of fans
There are different varieties of fans, which are divided by the way they are mounted:
The last two types do not need to be assembled after they have been purchased. The last type (ceiling-mounted) is installed in a specially prepared mounting place.
They differ from each other by power, size, number of speeds, different additional functions and so on.
The first kind of fan is one of the most popular methods to cool. The main reasons for this prevalence are low cost, ease of use and installation, low energy consumption, mobility, versatility. Floor fan does not take up much space in the room.
According to the way they function, floor fans are also divided into:

- Bladeless. This variety is a round frame with a motor. The air stream is first sucked in and then expelled with acceleration.
Axial floor fans are the most common type. The entire room is not blown, but only an individual space.
Floor fan Energy EN-1616
Looking for positive and negative reviews of Energy EN-1616 floor fan?
We have compiled 7 negative, negative and positive reviews from 11 sources.
We’ll show you all the pros and cons of the Energy EN-1616 Floor Fan revealed through user use. We don’t hide anything and we post all positive and negative honest customer reviews about Energy EN-1616 Floor Fan, as well as offer alternative products similar. Is it worth buying. The decision is up to you!
Floor Fan Energy EN-1660.
Before buying any product, in this case Energy EN-1660 Floor Fan, it’s better to read reviews about it first. Read what other people have written about Energy EN-1660 Floor Fan, form your own opinion and buy it.
But if you’re not ready to buy yet, check out the specs, check out the prices, or read the discussions.
All reviews
Advantages: Surprisingly quiet or our office is big just)
Comment: Worked all summer, disassembled. Took it away for the winter.
Advantages: For its cost good power
Advantages: Remote control
Disadvantages: Low power, you need to sit within one meter of the fan
Advantages: All parts are in place.Assembled it myself. Everything works
Комментарии и мнения владельцев: Great for the money just great
Advantages: It works as usual. Three speeds. No remote control. Flimsy. But if you put it on and turn it on it’s fine.
Cons: Works quietly, creates a cool breeze indoors.
Disadvantages: A little bit of a pain to assemble the main part, but then figured it out. For those who read the instructions and use them to assemble, not everything is understandable. Some things are not listed.
Comment: A real salvation in the heat! If you are not always exposed to scorching sun, you can do without air conditioner. The fan can cope.
Strengths: works great, blows well
Комментарии и мнения владельцев: Great fan for the price, no noise, the package came complete
Strengths: Pretty powerful blowing. I use it in a small room, first rotation speed is enough.
Disadvantages: The package includes the plugs for the feet, but the manufacturer forgot to put them. No plugs makes it unstable. Price is too high
Комментарии и мнения владельцев: Flimsy and loose. Price. Doesn’t match in my opinion, too high
Strengths: It is as advertised
Комментарии и мнения владельцев: normal fan for the normal price, no new products
Disadvantages: blows badly, the blades are not at the right angle, did not remodel, just gave it away
Review of Energy EN-1660 floor fan
AdvantagesCool fan only for as long as it lasts
DisadvantagesBadly blows, the blades are not at the right angle, I did not remake, just handed
Your review will help someone make a choice. Thanks for sharing your experience!
Best buying options at a low price
Where to buy cheap? Consider offers with delivery or self-delivery. Online price comparison. Choose a convenient place to buy.
You may also be interested in what this product is often bought with
6 of 2657 products in the “Household fans” category
Floor fan Energy EN-1660: whether to buy, description, photos, features, customer reviews, instructions and accessories, assembly of the unit, review.
© 2017-2022 Ogon.Guru. Online magazine about charcoal grills, stoves, grills, barbecues and other garden and home appliances for cooking.
The information is provided for information purposes only and does not constitute a public offer. We are not a store, we don’t sell or deliver. Through our service you can find the products you need, go to the store and place your order on the seller’s website.
Review: Energy EN-1618 floor fan. Create a more comfortable conditions in the house in the heat of the day
Greetings to all the guests of my review!We bought the Energy EN-1618 fan unplanned and quickly. It so happened this year that the hottest part of the summer my husband and I had to spend in the capital. My husband is being treated as an outpatient at a medical center in Moscow, we often make do with one day and go home, but sometimes we stay a few days. Then we either rent a hotel room or go to a friend’s place, who has kindly offered it to us for the treatment period. There’s no air conditioner in the apartment and in order to save ourselves from the heat we decided to buy a floor fan so that the owners of the apartment could just leave it behind.We had no energy, time or desire to choose, so we found an interesting option on the Internet. We have to go to the store and order a delivery.
Maybe we have not paid attention to fans that are now offered by retail chains, but we liked the floor fan Energy EN-1618 very much for its compactness and modern design. was a little high and there was of course a high demand for them in the hot. But when after buying the fan I met the for exactly these fans on WB and Ozone, 7000 and 6500 respectively, my indignation had no limits, that’s how traders make their millions, using the difficult situation. Out of spite I took and cancelled unfinished planned purchases on these Internet. stores, a sign of my protest.
The manufacturer of the floor fan Energy EN-1618, China.
The fan is sold in a thick cardboard packaging, the packaging shows the main characteristics of this fan. Since the basic material of which the fan is made of plastic, I think the weight of the package along with the fan about two pounds. The fan is shaped like a solid column, which is 74 centimeters high.
The package contains the column itself, two parts of the stand, and a small user manual in Russian.
Assembly of the fan takes a few minutes, you only need to screw two parts of the stand with three screws to the column itself.Floor fan Energy EN-1618 black glossy color, perfectly blends into the interior of the apartment, I’m sure the owners will be very pleased.And this is how the fan looks like from the back side.
On the top of the fan. of the column is the speed switch, there are three of them. Speed change control is mechanical, the principle of operation is centrifugal (radial).The fan can blow both only in one direction and rotate around axis on 45 degrees in both directions. The mode is set by the switch (knob is light. blue) from position “0” to any position to the right or left, selecting the desired airflow rate.
To turn off the fan you need to put the switch of speeds in position “0”.Power of the floor fan Energy EN-1618 40 W.For the transfer of the fan to another place there is an indentation at the top of the column, it is convenient and easy to carry.
The power cord of the fan has a length of 2 meters. The cord is equipped with a regular plug, here the Chinese have definitely made a mistake, they could have put a fork in the euro.
The fan guards are plastic, the dust is well electrified on them, but there are no problems with cleaning, everything is cleaned quickly and easily with a soft cloth.
The warrantee time of the fan is one year, life time is not long, only three years.We have been using the fan for about a month and we can already say about all its advantages and disadvantages.The fan is cute, stylish, compact, takes up little space in the apartment and if it is not needed, there is always a place for it in the apartment. You can put it in the closet or just near the furniture. By its appearance the fan is often mistaken for a music speaker.
The fan base consists of two halves. When assembled the stand is round and has a diameter of 21 centimeters. On the outside such a stand I do not inspire great confidence at all, the walls are very thin. We do not know yet how durable it is, we are very afraid of stepping on it accidentally.
Generally the fan is too light, but the manufacturer says that the fan is very stable on the base. But only if no one touches the fan. A slight bump can cause the fan to fall to the floor and then you just have to rely on the strength of the plastic. For a house with small children this probably is not a good option.
The three speeds are of course cool, but speed 1 is barely noticeable air movement and we never use that speed at all. Speed 2 is of course noticeably stronger, but not for such an African heat like this. Our fan runs constantly on speed 3, it only turns off when we leave the house. And so all night, and day the fan runs nonstop. Works without problems without heating at all. Despite the rather frequent plastic grille the airflow is good, quite strong. The apartment is two-roomed, small, set the fan on the border of the two rooms and setting it to turn it works enough for two rooms. The breeze from the fan pleasantly freshens the air in the apartment.But the fan still works a little noisy. In the beginning you don’t notice the noise, but when you turn it off in the morning you immediately understand how pleasant the quietness is. Of course the fan can not rush the air quietly, we have to put up with it and just wait until the African heat will leave our territory.
Another drawback of the floor fan Energy EN-1618 is that it is not adjustable in height. That’s how it has a height of 74 centimeters, so he blows at this height. For the night is quite enough, but during the day it would be nice to increase the height of air flow, but this is not possible.And it is not bad at all to have such fan with a remote control, so it is possible to switch it on. to switch it off or change a speed. I was against to buy a fan with a remote control, but now I realized that it was wrong and if I have to buy a fan, I will buy it only with a remote control.And I will certainly recommend Energy EN-1618 floor fan for purchase. modern, lightweight, convenient, compact.I thank everyone who has read.I wish all only pleasant purchases!See you in the next reviews!
Floor Fan Repair with Your Hands. All the reasons why it won’t spin and how to disassemble.
On the hottest summer days, the only salvation from the sweltering heat is a regular floor fan.
Not everyone can afford a full-fledged split system or even a mobile conditioner.
But unfortunately, even this inexpensive and affordable windblower, breaks down from time to time. Especially Chinese models fly like sunflower seeds.
And they are in our market in the vast majority. What to do if the fan stopped rotating and working? What are its main weaknesses and why it breaks?
In total it is possible to distinguish 5 main causes of floor fans failure:
The main problem of cheap models, which for some reason not many people pay attention to. The wrong casting of the blades. It causes imbalance, broken bearings, increased clearances.
You can not influence it, because you have already bought the fan with this initial defect. Sometimes it seems to work, the impeller rotates normally, but it does not blow.
That is, there is no cooling airflow from it. Why is this happening??
Because of the wrong angle of attack of the blades. Its blades are deformed and transmit the air flow in a circle, instead of blowing it out.
This effect can appear over time, after the fan has stood for a long time in direct sunlight and its impeller heated up, began to gradually change its shape.
This can only be cured by replacing the impeller with a new one.
The most common problem is dry lubrication or lack of it. The fan begins to jam, loses speed and as a consequence, the load on the engine increases. The blower is no longer working at full capacity.
The engine wound with a thin wire of 0.2 mm begins to warm up and gradually burn out windings.
How such a defect is detected? In this case, the fan stops rotating. It is humming, but the impeller does not turn.
And sometimes it starts only at the 3rd speed, and does not react to the first two speeds. It just doesn’t have enough power to turn the shaft.
To start it, you have to spin the blades like on old planes.
By the way, the same symptom can be with a damaged starting capacitor. How do you know which cause is to blame for the failure without instrumentation??
You must at least get to the motor shaft by removing the protective shroud and blades. If the shaft by hand will rotate with great difficulty, then blame dirt and dried grease.
If it rotates easily and has inertia, it is likely that the condenser is dead. The symptom is. You plug in the fan and it won’t turn. You crank the motor with your bare hands and it will start.
If you hold the fan blades down with your hand while working, it can stop again. Check the capacitor with a multimeter, if it has the appropriate capacitance scale.
For replacement, select a new cooler with the same parameters that are listed on the housing of the old one.
By the way not completely dried out condenser also affects rotation speed. If you notice that they have dropped and the fan is spinning slower, it is a bell to check it.
The problem of stiffness can be solved by relubricating the bearings. Here are the so-called slide bearings. Some people call them hubs.
Use balls in such designs is expensive, and over time they rattle a lot. You don’t have to take the whole engine apart to repair it. It is enough to loosen a few screws and spray in the right places with a universal spray WD40.
How to get to the bushings without removing the engine? First, you unscrew the central screw on the back of the guard.
There is another screw hidden in the adjusting button lever to turn or stop the fan head.
After that the rear cover can be easily removed from its place. What’s Under It? Here you can see the swivel gear, which makes the whole head rotate.
There’s a special rod underneath.
The engine starting capacitor is mounted on top.
By the way, keep in mind that in different models it might not be there. In this case look for it near the gear shift buttons.
To access the motor bearing you need to remove the gearbox. It is mounted on three screws and is supported from below by a pull rod.
Loosen the screws and disconnect the rod. The gearbox is then removed from the shaft and you have access to the rear bushing.
There is no need to unscrew or disassemble anything else. Wetting oil will do the rest.
Put a thin tube of WD40 on the can and spray a few times in the gap between the shaft and the bearing.
After spraying with WD40, turn the shaft by hand in different directions and move it back and forth a little.
Excess thickened grease, debris and dust will slowly come out. That excess dirt is easily removed with a cotton swab.
If you have a thick grease such as Citim or Lithol, it is advisable to apply it to the gear worm. After these cleaning procedures, drop a few drops of sewing machine oil on the outside of the bearing.
Just don’t apply it too much. Otherwise, it subsequently spreads all over the place and the dust adheres to it, turning back into dirt. You end up with the wedge and the rotation problem of the fan again.
Some models have felt washers near the bushings. They are impregnated with oil and when heated, the oil drips onto the shaft, lubricating it.
Reassemble in reverse order. Traction. The three screws on the gearbox. outer cover.
By the way, if you over tighten the central screw on the back cover, and it is a screw, not a screw, it can go through the plastic of the swivel gear and bump into the shaft.
With the rear bearing solved, now move on to the front of the fan. There is a protective cap in the center.
It unscrews, pay attention. clockwise because the threads are left handed.
You take it off and remove the propeller from the shaft. you get access to the front plain bearing.
The principle is the same. First you squeeze out and soften the old grease and dirt with liquid cleaner, then apply the new grease.
After that you put the propeller back on and close the cap. After finishing the repair turn on the fan at high speed and after running it a few minutes switch it to the needed speed.
If the damage is more complicated and simple lubrication does not help, you have to disassemble the fan in detail.
First do all the manipulations of the disassembly as above. After removing the propeller, unscrew the plastic front locknut that is right behind it and remove the whole protective frame.
In the hands you have the motor itself and the leg, in which the power wires and the pushbutton mechanism is located.
Take apart this leg by unscrewing the 6 tapping screws.
The first thing to do is to check the solder wires. It is possible that one or more of them fell off or burnt out.
If it is intact, how do you know which wire is going where and what it is for?? Begin the test with two wires from the power plug.
One of them, let it be black (as in the photo below), through the light bulb goes directly to the fan motor.
The second wire goes to the lower terminal of the dial switch (button 0).
Then, by pressing the corresponding buttons. 1st speed, 2nd, 3rd, one or the other contacts of the switch are closed, and thus the speed of the motor changes.
Each wire from these buttons goes to a different terminal on the winding, with more or fewer turns. By putting voltage on them, you make the propeller spin faster or slower.
A simplified schematic diagram of the fan looks like this.
Typical diagrams for most inexpensive 3-speed floor fans are about this:
Each push of a button causes its contact group to close.
The other contact group opens at that moment.
Sometimes these contacts get burned out or don’t reach their plate. Then you lose one of the speeds.
All this is checked elementary with Chinese multimeter, in a circuit checker mode.
If you break the very first wire, or there is no contact on it, the fan motor just will not start. So when the fan is completely off, check it first.
If you have checked beforehand if the plug and its power cord are faultless. This can also be done with a tester.
Place one end of the probe on the plug pin and touch the other end to the contact pad on the “0” button. If correct, there should be zero resistance.
Then you can check the wires on all speeds in the same way. The contact probe on the plug. with another probe on the lead that goes from the corresponding speed button to the motor.
If there are zeros everywhere, then your switch and wires are working.
Then you check the second contact on the plug and the wire that goes directly past the switch to the engine. Make sure that you have an intact cord here as well.
Only after that can you move on to checking the windings of the motor itself.
Use a multimeter to set the resistance to 2000 ohms. Next, to avoid biting out the wires anywhere, at the point where the capacitor is connected, strip a little insulation.
Look for common ground as in the diagram below.
Having found it, you call the resistance of the winding. To do it, touch the contacts on the switch with the second probe in turn.
Approximate values of resistance of fan windings can be the following:
Of course they can vary a little from model to model, but the most important thing is that there is no interruption or short circuit. Measurements can show several hundred ohms and a bit more than 1 kOhm.
It depends on the power of the fan and the wire size.
The resistance between the winding pins is already smaller. 100-200 Ohm.
Also check the capacitor winding and the total resistance of all windings combined.
Here is the most competent and complete video on how to check the health of the fan windings with a multimeter.
If checking the continuity of the windings does not indicate any anomalies or defects, go ahead. To do this you disassemble the fan to its bare bones.
First you have to free the motor from all the plastic parts. Unscrew the 4 screws on the front side and remove the cover.
On new models besides the screws there are also latches. You need to bend them with a screwdriver.
To disconnect the leg, you need to find another screw, which is usually hidden under the plug.
Loosen it and pull out the mounting shaft. To disassemble the wires that go through the leg, you will need to bite them out or solder them out from the terminals on the speed buttons.
At the same time, write down or sketch which one was originally plugged in.
As a result, you should have in your hands a bare fan motor without anything else.
Take it apart. Unscrew the screws that fasten the back cover.
In doing so, be sure to mark on all covers and hardware before disassembling how everything was originally assembled.
Otherwise you will lose alignment if you don’t reattach it correctly. There will be problems with jamming of the shaft and rotation of the blades.
After removing the bearing, you get to the windings themselves. Among the bundle of power wires coming from the switch, look for a special thermostat.
It’s very common for a motor to stop working after it burns out. This relay must operate and open the circuit, at a winding temperature of 135-145 degrees.
After cooling, the relay closes again and the fan starts. So, sometimes it burns out completely and actually plays the role of a fuse.
If your fan began to turn off frequently and restart independently, this protection is to blame. Know that it does not work for no reason. That means you either have a jammed shaft or the windings are overheating.
Overheating of the windings can be caused by the breakdown of a small impeller that sits on the shaft inside the motor itself. It is designed to blow and reduce the temperature of the windings.
You don’t have a temperature sensor-relay on the cheapest models. Proceeding from this, if your “thermal fuse” burned out, it can certainly be bypassed and start the fan. But it will leave you without fire protection.
Between its legs there should be a circuit in the mode of the wire.
If all parts and relays are intact inside, all you have to do is look carefully through a magnifying glass at the winding, shaft and rotor. You might see some torn or torn copper wires.
It happens when the bearing pops out of its seat and the rotor starts to beat on the windings.
How to install a rechargeable fan
At modern Chinese floor fans, quite often the screw connection between the two halves of the motor loosens. Do not forget that the shaft on both sides, put on self-centering copper-graphite bushings, which are tightly locked in the covers.
When assembling and tightening them, you can lightly tap the transformer iron itself with a hammer so that the shaft turns easily, with little inertia. Some people try to catch the center by themselves and make this silent horror.
Eventually, the shaft falls out of the bearing, resulting in a wedge. As a consequence, the rotor starts to scratch the windings and its surface.
Also keep in mind that if your fan fell and then stopped spinning, it’s likely that the bushings are misaligned. Nothing else can break from such a fall.
The capacitor will not be damaged, and the windings will not break. Except that some of the buttons might be loose. But first of all check the alignment of the bearings. And then everything will work as it should.
Unfortunately, a mechanical defect in the winding or rotor, or a short circuit inside the winding, cannot be solved by yourself. It is not rational to rewind the motors of cheap wind turbines, it is much easier to buy a new model.
But this is the last stage of the check, and hopefully you will never get to it, finding the damage somewhere else, by the methods discussed above.