Home Water heaters Foam for underfloor heating with beads
Water heaters

Foam for underfloor heating with beads

Underfloor heating mat with bosses (without foam) Energofloor Pipelock Solo, S=0.77 m2

Russian company ROLS ISOMARKET has been working on the Russian market since 1994. For the last five years the brand specializes in the production of technical insulation based on polyethylene foam, which is produced under the trade name Energofloor. Since then the company occupies a leading position in the sale of polymer heat-insulating products. The assortment of the brand offers a wide variety of products. The manufacturer specially for underfloor heating has developed a novelty. the mat for underfloor heating with bosses (without foam) Energofloor Pipelock Solo. 1,1-0,7 S=0,77 m2.

foam, underfloor, heating, beads

Peculiarities of Energofloor Pipelock Solo construction

The Energofloor Pipelock Solo slab is a representative of the renewed line of products for underfloor heating. The material for the product is polystyrene. The polymer is durable and can withstand considerable loads. the installer can put his full weight on it without fear of damaging the board and deforming the bosses. Mat has no thermal insulation layer. The mat can function at a temperature of 70 degrees. The polymer that the boards are made of is classified as a flame retardant material. Polystyrene is completely harmless to human health.

Energoflo pipelock Solo provides fast and high-quality installation of pipes for underfloor heating. The manufacturer has provided a “interlocking” type joint for a secure connection of mats with each other. Energoflo Pipelock boards are connected by overlapping joints. The result is a uniform panel of boards. The lack of thermal insulation layer makes the mats as compact as possible. This feature simplifies the transport process and saves space during transportation. Also, the updated design of the boards minimizes the amount of waste during installation.

Mats for water underfloor heating (thermal insulation)

Underfloor heating creates maximum comfort in the home and optimizes the temperature regime. Underfloor heating also saves up to 30% energy. If your home has high ceilings, savings can be up to 50%. Underfloor heating contributes to an even distribution of heat throughout the room. Underfloor heating is completely safe for the health of the occupants, but it has a negative effect on pathogenic bacteria, mold and mites. With floor heating system you can easily maintain the desired level of humidity in the room.

Underfloor heating systems can be used as the primary source of heating, or an additional to the central heating system. If the floor heating will be used for backup heating, use foil substrates in rolls. On the domestic market there is a huge variety. Basically, the base of the substrate is made of polyethylene foam, the thickness of which varies from 2 to 10 mm. The outer side of the substrate is covered with aluminum foil. It effectively reflects the heat in the right direction. Polymer film is not afraid of organic acids and aggressive compounds. Concrete, gypsum and lime.

Mats for water underfloor heating

In the company “Gulfstream” you can buy quality materials for arrangement of thermal insulation layer in the underfloor heating system. We offer products only from trusted manufacturers, the price of mats for water underfloor heating is one of the most profitable in Moscow.

Practice shows that the efficiency of underfloor heating system directly depends on the thermal insulation level of the substrate, whose main purpose to create a kind of barrier between the rough floor and the pipes with the coolant. At the same time the material used will perform several functions at once. to block access to the cold from the base, distribute heat over the entire floor area and prevent its leakage. And also to act as a sound and waterproofing, providing protection against leaks. In our range you will find all kinds of thermal insulation. Styrofoam boards and mats for the water floor, as well as foil-lined polyethylene foam substrates.

Recommendations for the selection of mats

Choosing insulation gasket for water underfloor heating, should take into account the technical indicators. Consider them:

  • the degree of waterproofing;
  • the ability to withstand any load. statistical or dynamic plan;
  • technical features of the room. You should not buy the cheapest and not high quality products.

When choosing, it is necessary to adhere to a number of rules:

  • It is better to give preference to products with a foil or laminated layer. this will ensure waterproofing of the structure and efficiency of the system;
  • Piping diameter and pitch must be taken into account. they must be compatible with these parameters of the mat;
  • The thickness must be chosen taking into account the level of insulation of the basis. in this case one should take into account the thickness of the screed and the thickness of the floor covering, so that the height of the structure will not exceed the allowable size.

If there is no need for additional insulation, the thinnest mats with bosses will be enough, they will facilitate the process of mounting the circuit.

In order to buy quality products from a proven manufacturer, and not to buy a “homemade”, you must demand from the seller to show certificates.

Rolled substrate is not a high degree of waterproofing, so it should not buy to place on the first floor, or for installation in apartment buildings, where the lower lived neighbors.

Since, in case of a leak circuit, it can not hold water, and it will seep down. For water floors are suitable polystyrene sheet mats with foil, they have enhanced waterproofing properties.

When constructing a hydraulic floor, the density of the material and the level of load that it can withstand is of great importance. In this regard, polystyrene and foil boards also win. These types of insulation are ideal if the system is done as the primary source of heating.

But the roll product is recommended for structures that act as an additional heating device, as it has a low density.

Installation of mats

Laying warm floor mats, whichever it may be, takes place obligatorily over the waterproofing. As the waterproofing can be a film coating the surface of the base of the floor or other.

Harpoon for fixing the floor heating

They are fastened by means of locking joints. If any. Sometimes it may be necessary to fix the construction to the floor, in case the mats are light and thin. This can be done with adhesive. Metal fasteners should not be used, as the floor waterproofing and other properties of the mat may be damaged.

If you install flat mats, which do not contain lock joints, they can also be attached to the floor with glue.

There are many nuances of installation, it all depends on the type of construction and its characteristics.

Laying of pipes is carried out after the warming mat is fully laid.

Installation has its own peculiarities. Before you lay mats under the underfloor heating, you should follow a few points. You need to calculate the heating power (measured in watts per 1 m²) and the area for the material. Then it is worth to decide what will be the installation pipeline scheme. The schemes can be of the following types:

  • Spiral. suitable for rooms with a small area.
  • Double helix. suitable for large rooms.
  • Serpentine. in this case, the pipes are mounted parallel to each other.

Choice criteria

When selecting mats, first of all you need to make sure that the material is authentic. The construction market is saturated with a variety of fakes, and with strict requirements for the properties and functions of thermal insulators, a mistake in this matter will be very expensive. Therefore, do not neglect to check the certificates of conformity and safety, as well as the presence of warranty on the product.

In order not to make a mistake when buying, choosing the right option, it is worth paying attention to:

  • level of waterproofing;
  • The ability of a particular model to withstand static and dynamic loads;
  • The diameter of the pipes suitable for laying on this type;
  • Requirements for the room in which installation work will be carried out.

Собачья Будка с ТЕПЛЫМ ПОЛОМ с Wi-Fi своими руками. Timelapse. Пошаговая инструкция

Double locking of the mats reduces heat loss and increases the strength of the connection. Installation of such a material is very easy and fast without much difficulty.

There are also a number of additional parameters:

  • Thickness. Choosing a material, take into account the height of the layer of screed and decorative coating. In rooms with already installed insulation, you can take the material of small thickness.
  • If there is a choice, without a doubt, you should give preference to mats with a foil-coated or laminated top layer. This immediately solves the problem of waterproofing before pouring the screed, and also increases the effectiveness of underfloor heating.
  • Pay attention to the compliance of the parameters of the mat to the planned diameter of the pipes of the circuit and the step of its installation. this does not rule out mismatches.
  • Take into account the area of the room in which you plan to lay pipes. If the area is large, it is worth giving preference to the material with “bosses”.

An overview of the best brands and manufacturers

Many domestic and foreign manufacturers offer quality products. According to the reviews of experts and buyers, products released under the trademarks deserve special attention:

The following brands of mats are in the greatest demand among buyers:

Designed for laying the water circuit with a pitch of 50 mm. The bosses of the material have special ledges and reliably fix heating pipes with a diameter of 14. 17 mm. Additional rigidity is provided by a rigid polystyrene film that covers the mats. The marking is made on both sides of the board. Locks are located along the entire perimeter. The back side of the boards has a soundproofing surface. The thickness of the material. 45 mm. The basis of 25 mm. The size of the plates 1,2 × 0,6 m.

The price of these mats is somewhat higher than analogues offered by other manufacturers. This is due to the design features of the model and the high quality. The material has high strength to withstand considerable load. On top there is a black polystyrene film, which provides the necessary level of waterproofing. The marking is on the back side. Pipes with a diameter of 14. 17 mm spacing is 5 cm. Mat height. 24 mm.

Offer from a domestic manufacturer. Designed for installation of water flooring with pipes of 16 mm in diameter. The plates have a dense base thickness of 30 mm, which provides the necessary level of thermal protection. Mounting apertures are located in increments of 50 mm. The size of the plates 100×100×5 cm.

Mats are recommended for installation of poured floors and arrangement of concrete screed. Have enhanced heat and noise insulation.

Roll-fed slabs covered with polypropylene film. Applicable for pipe diameters of 1.4 and 1.6 cm, as well as for laying pitch between 5 and 30 centimeters. The area of one roll. 10 sq.m.

Rolled mats for warm water flooring. Foil-coated, applied a coordinating grid with a pitch of 5 centimeters. The size of the roll. 0,5x120x150 cm.

Parameters of the choice of insulation, what we pay attention to

When buying a coating for a warm floor with polystyrene foam, you should take into account such indicators as: quality and variety.

Initially, the quality of foamed polystyrene boards for warm floors is determined by their appearance. The following points should be taken into account:

  • Color. should be bright and uniform, indicating compliance with the technological process. Most often sold in blue or orange shades. The color scheme itself does not affect the characteristics of the product.
  • Odor. it is unacceptable to have a pungent smell, a slight slight specific can be.
  • Shape. a clear geometric, and the edges are flat and not crumbling.
  • Granules. one size without voids.
  • The surface must be even, otherwise the heat insulating properties will be reduced.

For your information! Specialists recommend a special inspection of the place of the cut or break. In the integrity of the granules in this area, we can talk about their poor adhesion to each other. In a quality slab, when broken, the granules must also break down.

Varieties of mats for underfloor heating. What to choose?

For the effective functioning of the underfloor heating is important to know how to install it. One of the main elements of the installation of construction in the obligatory use of insulation. It is necessary to prevent heat loss and can save energy. For a long time, experts have used traditional heat insulation (foam, mineral wool, etc.), which have a low level of thermal insulation and uncomfortable when laying. The most common and comfortable in the installation of warm floor insulation to date are mats of polystyrene foam. This material has proven its worth with its unique characteristics:

  • low vapor permeability. This means that the mat does not accumulate moisture in itself, thus preventing the formation of condensation, and the floor is always dry;
  • low thermal conductivity. This characteristic contributes to the accumulation of heat in the room;
  • soundproofing effect. Relevant in homes where there is increased audibility through the thin concrete slabs;
  • Has antiseptic properties. it does not breed fungi and other micro-organisms. Not interesting for rodents, as it is not their food;
  • durability. In conditions of constant temperature fluctuations can serve up to 60 years.

For laying underfloor heating mats of polystyrene foam with a density of 35 kg/m3 and a thickness of 5-10 cm are suitable. Such decking perfectly withstands loads, which in this case is very important, given that it is laid on the entire design of a warm floor, plus a concrete screed.

Tips for laying a warm waterborne floor with the use of Thermopolis thermal insulating mats

It is already unnecessary to convince anyone that Termopol KAO underfloor heating mats significantly facilitate the installation of the water floor and make the work of the contractor faster and more effective. However, the benefit of buying mats is not only the convenience for installers. Carpet pad made of polystyrene foam, above all, is an excellent thermal insulation, which significantly reduces heat loss through the ground or the ceiling down and at the expense of this subsequently helps the owner of the premises to save on heating. It is also aided by interlocks around the perimeter of the boards, which firmly connect the mats and prevent leaks of cement grout and the formation of “cold bridges. Protruding bosses serve as guides when laying the pipe, which can be placed, observing the same between coils with a laying step of a multiple of 5 cm. This helps to avoid “blind” zones, and the floor in the operation will be heated evenly.

Preparation of a surface before laying Thermopol KAO mats

One of the most often asked questions: on what surface it is possible to lay mats for a warm floor. Thermopol KAO mats can be placed on any solid even surface. The subfloor (screed, floor slab or compacted soil) may have small irregularities, but must be cleared of debris. Deep unevennesses can be backfilled with sand.

Laying under mats of the polyethylene film is not required, as the polystyrene foam does not absorb moisture, neither reacts with floor slabs, nor with the ground, nor with other solid materials. As for the advisability of waterproofing in case of leaks in the water pipe floor, in such force majeure circumstances polyethylene film is unlikely to help. Leaks tend to occur if the object used low-quality pipes and equipment, if the work is performed by unqualified professionals, as well as if there was damage to water heating pipes by other workers or the owner of the premises after the filling screed. As a curious example, when the workers laid parquet over the screed, not knowing about the existence in the room of the underfloor heating, and “for security” parquet boards were attached with long nails)))

How to choose a brand of mats for underfloor heating

If the water floor system is mounted in a dwelling house or office, you usually use M-35 boards with a density of 25-26 kg/m3. For the rooms with low passability this grade is enough, and it does not make sense to overpay for denser mats. In areas with heavy loads, such as garages or car showrooms, use a brand M-50 (35 kg/m3) or M-50 Premium (45-46 kg/m3). If necessary, you can combine different board densities in one room. When using Thermopol KAO the mesh for the screed is not required. Boards are quite dense and do not sag over time under the screed. And bosses serve as an additional reinforcing element when pouring mortar.

How to install KAO mats correctly

Thermopole is started from the doorway. The boards are joined together by pressing lightly on the locks until they snap into place. If the pipe connection is made from another room, the rows of barrels must be aligned in the area of the door opening.

The recommended step of laying the pipe is 150-200 mm. It is enough to fix the pipe to the screed only in the places of its turns. For this you can use fasteners. dowels for thermal insulation or dowel hooks. If the mats lie tightly on the floor surface, you can use harpoon anchor clips to secure the pipe in places where it turns to the mats. The length of one heating circuit should not exceed 80 meters, otherwise the heating will be uneven.

What is damping tape and what does it serve for

Before pouring the screed around the perimeter of the room, install a damping tape in places where the screed touches the wall and to separate zones with different heating circuits. Damper (edging compensatory tape) is designed to create a cushioning layer between the floor and the wall and prevent the pressure of the screed on the walls during the thermal expansion.

During the works on Thermopol mats with bosses it is possible to walk on them without damaging the pipes laid in. This is another important advantage of Thermopol KAO mats (remember about leaks)?) However, if it is necessary to carry considerable loads, for example, buckets with cement mortar, it is recommended to lay “paths” made of plywood or boards on top of mats with pipes. Beads on the substrate Thermopol, especially if used grade M-50 and above, can withstand even a very substantial load.

The recommended thickness of the screed is 4-7 cm. Screed is made as usual, according to the set beams. It must be well dried before it can be walked on and proceed to install the final floor covering. Pouring screed, you should make sure that the solution enters all the recesses between the barrels and tightly embrace the pipe. Voids in the screed reduce the heat transfer from the coolant to the heated surface, and may also lead to its subsidence over time.

It should also be borne in mind that semi-dry screed due to the presence of air in it has a lower heat transfer compared with the usual “wet”. Laying under the mats of foil material for the heat transfer does not matter, because the heat is reflected from the foil only in the voids, and under the screed does not happen. Also, note that the unprotected surface of the foil under the influence of the cement mortar will eventually deteriorate. Therefore, laying foil under mats and concrete mortar makes no sense.

The photo was taken during the working installation of a hot water floor at a real facility. So you see Thermopol KAO, without any embellishment, as it looks and is used in real life.

Where you can buy Thermopol KAO mats

Mats for underfloor heating Thermopol KAO can be purchased from the manufacturer by contacting us in any convenient way listed on this site. You can also buy FAO mats from our official dealers, the list of which you can find in the Where to Buy section. of this site.

Author

Kerariel