Councils for the repair and adjustment of the boiler Fundal Victoria

Wall gas boiler Fondital Victoria Compact 24 does not launch. If we press the power button, the burner works normally. But it is worth not fixing the key, the device begins to wander. Explain the reason for the problem?

Presumably, a defect in a thermo.element or a breakdown of a gas valve. There is also a decrease in gas pressure on the entrance line. In some cases, there is a lack of voltage of the electronic board.

There was a malfunction. Start is very difficult. The lighter is on, and the main burner is not there. Help me figure out what is the reason?

Most likely, violation in the operation of the node. We advise you to conduct a technical inspection of the boiler and clean the ignition device.

Why the gas boiler Fontille Victoria Compact cannot disconnect when heating reaches the required temperature? It heats up to 90 s, then a problem occurs. When rebooting, the problem should be again.

Perhaps the board is not in order, the boiler water temperature sensor has damage, the safety sensor button broke. It cannot be ruled out that the automation settings have arisen.

Tell me why it is not possible to raise the temperature of the coolant above 70 degrees? We want to install more, but the screen shows that this is the greatest value. How to increase heating?

If the device does not increase the temperature in the heating system, then the following problems are possible. In the settings there is a limit of the maximum heating temperature not higher than 70C. The drop in the chimney can be traced.

Fondital Victoria CTFS 24 AF boiler incorrectly performs work in terms of heating the DIS system. From the crane comes in turn either cold water, then hot. Tell me what reason it could be?

The causes of a malfunction may be the following. Cold water can be mixed due to the fact that a three.way valve is faulty. The heat exchanger is very contaminated. It is necessary to clean it.

There is a crane under the boiler, water often leaks from it. The device itself does not work. What should I do?

Apparently, the coolant follows from the protective valve. This factor shows that the pressure in the system is increased. The system filling crane could also be open or it is recommended to pump up the expander tank.

Explain what a malfunction is when the pressure is constantly raising, and also comes into effect the reset valve? On the screen, an icon of heating in the heating cycle of the device is issued each time. How to be?

There is a malfunction of the temperature sensor of the heating line. There is no normal circulation in the heating line.

What is the breakdown, when the wall.mounted boiler Fundal Victoria began to be disconnected repeatedly? In particular, today the piezen did not work at all. The apparatus was cleaned a month ago. What could be?

There is a suspicion that there are problems in the smoke removal system. You need to check the chimney. The inoperability of the roser element will mean a breakdown of one of the components after an inconsistent voltage or the penetration of water.

Please help me deal with the chimney? For 2 days, a reverse traction occurs, in which smoke falls into the room immediately. The chimney was made by me on my own. It is a steel pipe. Perhaps somewhat allowed inconsistency.

The unit works normally for hot water supply, but if you turn on the heating, the water boils quickly, and the device gives out a failure. What is the malfunction and how to get rid of this?

It seems that the circulation pump does not work, the electronic board failure, the temperature sensor is faulty. At the same time, the filter mesh mesh can clog.

In the hot water supply cycle, the device alternately gives out either cold or hot water. It is not clear what it comes from. How to adjust the heaters heating?

Apparently, there is contamination in the heating system or you need to clean the heat exchanger. There may also be damage to the sensor that controls the pressure, or the circulation pump is faulty.

The main reason is an incorrectly manufactured chimney design. Perhaps the deposition of soot on the walls of the pipe, which sharply reduces its useful action coefficient. In addition, it is required to inspect the ventilation holes in the room.

Installed and connected the Victoria Compact CTN 24 AF gas boiler. He quickly gains temperatures up to 96 s, but then rises by overheating. In the future, when it cools, it goes to the reboot. What is the problem?

The overheating accident means the termination of circulation in the system. It is pre.recommended to monitor the taps of radiators. They should be in the open position. Next, a check for pollution of the filter element is carried out, and it is also necessary to make sure that the heat exchanger contains dirt.

Launched the same model in March. Presumably a month and a half later, the device began to make great noise. Explain what is the reason that in the boiler noise?

There is probably a scale in the heat exchanger. When the water is hard, then over time, lime accumulates in radiator tubes.

They would like to install a boiler Victoria Compact for heating the house. Interested in how it is necessary to correctly launch such an unit into operation?

For the correct launch of this equipment, we recommend that subsequent operations perform subsequent operations. We turn on the electrical power of the device. Set the gas tap in an open position. Then we launch a gas.regional equipment. After adjust the right one.

I need to perform maintenance. Advise how to properly drain the water from the apparatus?

According to the manual, such a procedure is performed in the following order. Disable the device from the electric network. Close the gas tap. Open the air engineer. Open a completely drain. Then collect the spilling fluid. You can also drain the water using the protection valve. Such a valve is located at the bottom of the unit.

Please tell us how to check the functions of the 3x-logo valve? It seems to me that this detail does not perform the discovery. Far radiators cannot pump heating, however, a pipe is warming on the hot water for the receipt of heating water under a boiler unit.

You are right, we recommend that you look at the 3x-lane valve relatively bad stroke of its rod in an intermediate state. We also recommend diagnosing your heating system.

Fondital gas boiler. malfunctions and problems

Any technique fails from time to time, even if we are talking about highly rental equipment of the European brand. There is no exception to the hotel equipment of the Italian brand Fundal.

And this is not surprising, because under Russian operating conditions, which are characterized by increased rigidity, even highly reliable equipment from time to time loses its performance. And breakdowns, like their reasons, there may be many. It is about the typical problems that domestic buyers of Italian boilers face, and will be discussed below.

Gas ignition does not occur

Often, buyers of the equipment of the funds complain about the following kind of problem. After several years of operation during the next seasonal launch of the equipment, the gas is not ignited the first time. Users have to restart the unit several times, after which it, in the end, begins to function. In this case, for the normal operation of the unit, it is necessary to set the maximum temperature of the coolant. When you turn on hot water, the unit may turn off, and in turn the red indicator lights up.

As a rule, such malfunctions of the boiler funds are eliminated by replacing the smoke pressure relay. Replacement can be made with the help of a master or independently. In the second case, you need to remove the casing of the boiler, which is located on the left side of the structure. Smoke pressure relay looks like a round plastic part. It must be removed and replaced with a new.

Intermittent flame or complete absence

In the gas boiler, the Fundal of this kind of malfunction is also far from uncommon. If when the boiler is turned on, the flame burns intermittently, then this may indicate the need to clean the fan. Often this is enough to ensure that the equipment begins to function normally. If the problem is not fixed, it makes sense to contact the master.

Unstable work of the boiler

There are times when customers who have bought the funds of the fund, note the instability of its work and high gas consumption. In addition, with frequent shutdown of light and a drop in pressure, the situation is aggravated. As a result, the equipment does not cope with its main function. providing the room with warm and hot water.

In such a situation, you should not be upset and intend to sell your boiler for spare parts. For the most part, the problem is not related to the design itself. For example, a problem may be in a supply gas pipeline and is associated with unstable fuel pressure in the system. In this case, you should call a professional who will check the entire heating system for the presence of malfunctions.

The boiler flows, and the pressure in the system is absent

If you are faced with a situation when your boiler after several years of correct work suddenly began to leak, then do not rush to contact the master. It is necessary to check the condition of the expansion tank. Often a problem is associated with violations of the state of this particular structure.

In the boiler, the Fundal Victoria Falf Democratos of this kind is not uncommon, so it makes sense to check the pressure in the expansion tank from time to time. Level 1.8 atmospheres experts consider it sufficient for the normal functioning of the unit.

A sharp increase in pressure with temperature growth

If you are faced with this kind of problem, then it is worth checking the condition of the connecting tube of the expansion tank. Often, during the installation process, the installers too much pipe the tube, which is why the excess of the coolant when heated is simply nowhere to go. In this situation, reinstalling the boiler to a more convenient place where the tube will not be deformed. In most cases, this works. If the problem has not disappeared, contact the master.

Pressure growth in the system when connecting a new branch branch of the heating system

If, when heating the coolant, the manometer readings in the system demonstrate significant growth. time to think about the acquisition of an additional expansion tank. Most likely, the one established at the moment does not cope with the actual volume of the coolant. Experts recommend in such cases to purchase an additional membrane tank.

As you can see, most of the malfunctions of the boiler funds can be eliminated with your own hands. But if you are not sure of the reason for the breakdown, then you should contact experienced specialists.

Fondital boiler errors codes

There is no incitement of the boiler fund. The gas mixture is not supplied to the burning node. It looks like a shut.off crane is closed. We recommend opening a crane located on a gas pipeline line. During the first launch from the pipeline line, it is necessary to remove the air. Construct the pressure parameters of the gas fuel supplied to the burning node. The required pressure is about twenty mbar. Then perform the diagnosis of the correctness of the settings of the smallest and greatest fuel pressure on the nozzle. Refractor indicators are available in the installation instructions. If required, we adjust the boiler. The gas valve is damaged. If the breakdown is detected, change the gas valve. The electrode of ionization acts unsatisfactory, or it is broken. Diagnize it for the presence of soot. Set up the distance between the burner and the ionization electrode, if necessary. Gas equipment is broken. Inspect the coils in the gas valve in order to fix the alleged short circuit or break. With these damage, put a new gas valve. The gas valve was stuck. Fix on a fitting placed on the front of the valve, a segment of the hose and form the limit pressure. Limited power of ignition. Make adjustment of ignition by power using the service menu. Function refusal or defect control board. The transformer of the ignition stopped working. Make a restart of the device. When the error returns, the control board must be changed. Drive the grounding. The sheathing should not have potential. Excessive amount of condensate can cause unit blocking. Clean the furnace, electrode of ionization and gas burner from condensate. Flame control failure. Control recorded the flame, but there is no combustion. Check the cable of the electrode of the ignition. There may be wear and tear. Inspect the electric circuit from the control board to the ionization electrode for the possibility of short circuit. INCOUNT INECTION OF INOCOLE CONTRACTION WITH THE BURNING NOT. The control board was damaged. It must be changed. Problems at the time of ignition. This situation may arise if the ignition mechanism does not work or the fuel of the burner flame is observed. It is necessary to diagnose connections between the node of the ignition, and the flame electrode, and also between the board and the gas valve. The main factor in separation of the flame of the burner may be a lack of traction.

Error with the code E2 (Red LED is on)

Fondital boiler overheating occurred. The temperature of the emergency thermostat is more than 105 C. If in this time there are no signals for ignition, then the error is not determined. The gas.lateral device extinguished due to the elevating temperature of the heating line, but the heating of the heat exchanger does not stop. In the heating cycle 90 s, in the water supply phase with hot water 95 s. The automation node stops working the boiler if, within 15 seconds, the temperature of the safety thermostat will become more than 105 C. When the thermmorlele is recorded in the heating or protection cycle against freezing of the temperature of more than 105 degrees, boiler automation begins to exert a delay in approximately 30 seconds. If in such a period of time the temperature of the safety thermorel and the NTC heating sensor will not decline up to one hundred degrees, the electronics will show the error. Disconnection of the device can occur when the signal is received for the ignition of the burner. If in the phase of the ignition the temperature of the emergency thermaller becomes above 105 degrees., The boiler will enter for 10 seconds in standby mode, and only then notify the malfunction. The temperature sensor of the heating line or the thermostat of overheating has worked, stopping the function of the device. The thermostat of overheating will start after raising the temperature over 105 degrees. Wait to cool the unit and make it zero by pressing the key/off key. Inoperability or violation of the thermaller of overheating. Change it. Limited circulation of the coolant of the main circuit. For the heating circuit, measure the pressure. Its values ​​in the cooled system correspond to 1.2bar. Excess air in the heating line. Remove excess air through the car carrier from the system. No circulation. Open completely shut.off taps that slow down the necessary circulation of fluid. The functioning of the circulation pump is impaired. The pump stopped reaching the necessary turns. Inspect the voltage and characteristics of the electric network. If you are detected in email.voltage chains, connecting the boiler to email.The networks are performed when using a transformer stabilizer. Carry the resistance check in the winding of the stator of the electric motor of the circulation pump for a break or circuit. The operation of the circulation pump is carried out as usual, but the pressure is weak. Apparently, the impeller has a malfunction. When determining damage, the pump must be changed. The pump does not spin, however, the supply to it is stable. We test the pump, presumably, it jammed. Remove the plug, then turn the rotary shaft of the electric motor. No power supply circulation pump. Controls’ malfunctions. It will be necessary to restart the Boiler Funding boiler. When the failure begins again, change the control board. The thermostat of exhaust gases began to overheat. Wait when the thermostat sensor has cooled, then restart.

Error code E5 (flashes red and yellow LEDs)

The temperature sensor of the heating system. There is a damage to the circuit or a short circuit of the temperature sensor of the heating circuit. When an electric chain of a thermal attenter has opened, the signal disappears, therefore the electronics board will send a message to interrupt the actions of the burner device.

Error E6 (blinks red and green LEDs)

NTC sensor DIS is faulty. During the presence of a rupture or closing of an electric circuit of a hot water temperature sensor with a cycle of three seconds, the gas.beam device does not function for water supply with hot water. The functioning of the Boiler Fundal will continue in heating mode. The problem in the operation sensor of the temperature line of the DHW line.

Error with the E4 code (yellow LED burns)

Reports that the level of system pressure is low. The main factors of the occurrence of this problem: low water pressure in the heating circuit. Lack of contact between an electronic fee and a relay from a sensor. Pressostat failed. First of all, it is necessary to look at the results of the manometer testimony. In many cases, malfunction can be eliminated using a feeding tap, which is mounted to fill the system with a coolant. When the accident is repeated again, then most likely, there is a leak of the coolant. A hydraulic pump, the main heat exchanger, a protective valve for discharge of excess pressure, damaged gaskets, a tap tile and other components can proceed. You can determine the visually hydroelectric power plants and components.

Boilers Fundal

On the boiler, the fund all the time is burning green indicator 1. T. e. Heating mode is activated. But the temperature is not regulated in any way, the radiators are constantly hot. And even if you try to turn off the heating with this regulator, there will be no sense. T. e. I have a heating mode is constantly on. What could be the problem?

The adjustment handle is broken, the temperature sensor is faulty, the board is faulty. Check in the indicated order.

Problem with Fondital Victoria Compact turbocharged boiler. After you close the tap with cold water, the heating pump is triggered for a few seconds. And every two.three three days I pump water, although there are no leaks. What could be the problem?

Somewhere the air along the hot water, the water gun lifts the float, it immediately drops and the pump is working out the run. As an option, you can try to put the check valve on the output

Victoria Compact boiler in operation 4th year, a closed combustion chamber, there is a room thermostat, so the heating system handle is 80 degrees. This season, he ceased to heat the water in the heating circuit to the desired value. Judging by the contactless thermometer, the heating pipe has a temperature of 60 to 70 degrees at different points in the boiler operating time (all measurements immediately after the next heating cycle). And in theory there should be up to 78 degrees. I understand correctly that the problem with the temperature sensor of the heating system? There are no problems on the hot water. The temperature smoothly changes in accordance with the lower handle. The manual has a large table with sensors resistance. it is not clear which column to check.

It is possible that right. To check, change the sensors in places.

Victoria boiler malfunction, in work for more than 5 years, worked well for no breakdown. Hot water is heated poorly. Previously, you turn on the tap, the water is cold 5l and it went hot, and now that the warm water of the degrees 35 should go about 50-70-liters to lower, I still waited. Hot, but not for long, 1.5-2 minutes and again the warm one goes about 5 minutes and the pressure rises from 1.3 to 3. Opened the device sprinkled from garbage, looked at the flame burning. It seems good, stable and blue. The expander disappeared, since there was no air, but everything was left as it was. What could be the problem?

Pressure in COs not just rises, maybe a three.way valve. Need to diagnose and check. Perhaps the heat exchanger was clogged.

Installed boiler Victoria compact 24. Worked normally, today I decided to have it, turned it off, drunk, I turned it on. does not turn on. It burns green, and when turned on, the green diode goes out, and another, yellow lights up. And all, a hundred times regretted already that touched him. I noticed that at the top of a sensor, (in my opinion, a thermostat of smoke gases) one contact fell off, screwed it with a suitable bolt, because of this all the problems?

Open the lid and check what contacts have disappeared.

Fondital Victoria boiler has arisen. It works stably, but, when working, pops are heard in the furnace. Can they be due to the fact that the lubricant from the ball valve has got into the gas distribution system? If not, then because of what these pop? Just a week ago, everything worked perfectly.

When the boiler is turned on the Tahiti Dual CTN 24 in DHW mode, it starts to work and turns off after 20-30 seconds, and then turns on again to heating and so constantly, and the water certainly does not heat up. How to fix? 4 years of work and was already washed six months ago. He also behaves on heating.

Check the sensors, even one of them, which is in the primary circuit, on the tube up to a three.way valve. Still, the duct of the main circuit is somehow limited somewhere, to look, maybe not miserable. Perhaps a malfunction of the management fee.

In operation, the wall.mounted boiler Fondital Tahiti Dual. Starts and rotates immediately. He called the master, he measured the gas pressure on the burner with his device and said, we must try a fee, but we do not have them in stock to check. If you can solder/repair the fee, turn to some points in the board, tell me, please.

Corrected by turning off the power for 10 minutes! The master has not yet called, the apparatus in the work of 7 years did cleaning 3 years ago.

When turning on, it works. After a minute or two, it gives out an error-insinuity of the temperature sensor of the hot water, but it works, after some more time it goes out and gives out another error “too high temperature”. What to do?

Replace the temperature sensor. Perhaps the heat exchanger to change.

Malfunction of the boiler Fundal Victoria. DHW is not regulated. The regulator is at a minimum, the crane is full open, and the maximum heating of the water is ongoing.

It is worth checking the gas valve control coil, as well as the control signal itself, if the device previously worked normally.

When the Victoria Compact CTFS 24 is turned on in heating mode, the indicator 1 with a pipe begins to blink red colors. If you follow the instructions, this error is interpreted as follows “High temperature of the coolant in the heating circuit (above 85C)”. Request to suggest what actions I should take to eliminate this error. Turned on heating, hot water was already turned on, worked for five minutes and now, when the unit is turned on, neither hot water nor heating is turned on. The pressure is generally at zero, it feels like it is blocked.

You can only start it with a tap tap. Support pressure. Check radiators for air availability.

By malfunction of the boiler Victoria Fundal 24. Recently, such malfunctions have appeared. When you try to ignite, it begins to click, both LEDs constantly blink one or another color, it lasts for about 5 minutes, then it still turns on and it can work indefinitely, then the red LED turns off and lights up and lights up and lights up. I drop an error, start, again clicks and LEDs burn for five minutes and it works fine again. 4 years ago I changed a fee, six months ago. traction sensor, in all in operation for about 7 years, the stabilizer is worth.

The fact is that just yesterday I had a problem with the 2-circuit gas boiler of Fondital, Victoria Compact CTFS. After commissioning and starting (hot water and 1 battery in the bathroom, through the collector) and, accordingly, the heating of the battery was heated about 80 liters of water. The heating circuit stopped working and subsequently began to flash a red indicator, allegedly informing about overheating and poor water circulation in the system. We have a suspicion of clogging filters on the collector. I think most likely, poor circulation due to a small heating circuit. But not a fact. I understand that the issue is not professional, but I will be grateful for possible solutions or guesses.

Malfunctions and repair of boilers Funding

The gas boiler Fondital Victoria CTFS 24, in the work of 2 years of which he did not use a year at all. The problem is this: I turn on the boiler, the ignition has gone, the gas is supplied, but the ignition indicator works. The red lamp blinked for a second, and it turns off, and so it repeats 3 times. After restarting, it can work stably for half a day. And then again what the reason is?

What to do with Baxi E133 error code on the GA range of boilers

Apparently, it is necessary to replace the press. Air pressure sensor.

A wall boiler is installed by the Fundal with a closed camera, after 7 years of operation, launched after summer downtime, a problem appeared. I do not use the DHW system, the heating mode of the boiler starts regularly, it works for a few seconds and turns off without issuing any errors, it began to cold, the batteries are slightly warm, I don’t know what to do, help, maybe he knows who is for the problem. The phasing is correct.

It seems that the temperature sensor is faulty. If you do not want to put a new sensor, change it with a temperature sensor.

Fondital Victoria CTFS 24 Double.circuit boiler. Does not work. The problem is as follows. When hot water (or heating) is turned on, the exhaust system is launched, the discharge is on the electrode, the gas valve opens, the fire occurs and, after 3 seconds, everything goes out (you can hear the gas valve). The system works out several cycles in this mode and knocks out an accident. Who has come across a problem, please help. I disassembled the boiler. I cleaned the combustion chamber. Cleaned the electricity of the fuse with the skin. Nothing helps. With fusion, the flame does not go evenly, but as if jerking.

It seems that the electronic control board will have to be changed.

In operation, the gas boiler Fondital Tahiti Dual CTN 24. There were problems of the hot water and. The problem of the following nature: when opening the crane of the GV, the boiler goes out and immediately starts and so does not yet close the tap tap. The hot water temperature regulator is tuned to at least, the water sometimes goes very hot, sometimes normal, warm, secondary heat exchanger cleaned a year ago. Recently, the same problem with the heating system. After using the GVS, the device begins to constantly beat, I am dumping, I start again. Everything is in order, but again repeats after about 1-2 days. The nearest service is far away and they are unlikely to go to me, there are no specialists in the village, please help with advice, what could be the reason.

It would be very necessary to check the adjustment minimum and maximum, it seems that the unit dumps power, and mines. 0 That’s the rotten. Remove, rinse and clean the 3-goal valve.

Victoria boiler malfunction, in work for more than 5 years, worked well for no breakdown. Hot water is heated poorly. Previously, you turn on the tap, the water is cold 5l and it went hot, and now that the warm water of the degrees 35 should go about 50-70-liters to lower, I still waited. Hot, but not for long, 1.5-2 minutes and again the warm one goes about 5 minutes and the pressure rises from 1.3 to 3. Opened the device sprinkled from garbage, looked at the flame burning. It seems good, stable and blue. The expander disappeared, since there was no air, but everything was left as it was. What could be the problem?

Pressure in COs not just rises, maybe a three.way valve. Need to diagnose and check. Perhaps the heat exchanger was clogged.

Installed boiler Victoria compact 24. Worked normally, today I decided to have it, turned it off, drunk, I turned it on. does not turn on. It burns green, and when turned on, the green diode goes out, and another, yellow lights up. And all, a hundred times regretted already that touched him. I noticed that at the top of a sensor, (in my opinion, a thermostat of smoke gases) one contact fell off, screwed it with a suitable bolt, because of this all the problems?

Open the lid and check what contacts have disappeared.

Fondital Victoria boiler has arisen. It works stably, but, when working, pops are heard in the furnace. Can they be due to the fact that the lubricant from the ball valve has got into the gas distribution system? If not, then because of what these pop? Just a week ago, everything worked perfectly.

When the boiler is turned on the Tahiti Dual CTN 24 in DHW mode, it starts to work and turns off after 20-30 seconds, and then turns on again to heating and so constantly, and the water certainly does not heat up. How to fix? 4 years of work and was already washed six months ago. He also behaves on heating.

Check the sensors, even one of them, which is in the primary circuit, on the tube up to a three.way valve. Still, the duct of the main circuit is somehow limited somewhere, to look, maybe not miserable. Perhaps a malfunction of the management fee.

In operation, the wall.mounted boiler Fondital Tahiti Dual. Starts and rotates immediately. He called the master, he measured the gas pressure on the burner with his device and said, we must try a fee, but we do not have them in stock to check. If you can solder/repair the fee, turn to some points in the board, tell me, please.

Corrected by turning off the power for 10 minutes! The master has not yet called, the apparatus in the work of 7 years did cleaning 3 years ago.

When turning on, it works. After a minute or two, it gives out an error-insinuity of the temperature sensor of the hot water, but it works, after some more time it goes out and gives out another error “too high temperature”. What to do?

Replace the temperature sensor. Perhaps the heat exchanger to change.

Malfunction of the boiler Fundal Victoria. DHW is not regulated. The regulator is at a minimum, the crane is full open, and the maximum heating of the water is ongoing.

It is worth checking the gas valve control coil, as well as the control signal itself, if the device previously worked normally.

When the Victoria Compact CTFS 24 is turned on in heating mode, the indicator 1 with a pipe begins to blink red colors. If you follow the instructions, this error is interpreted as follows “High temperature of the coolant in the heating circuit (above 85C)”. Request to suggest what actions I should take to eliminate this error. Turned on heating, hot water was already turned on, worked for five minutes and now, when the unit is turned on, neither hot water nor heating is turned on. The pressure is generally at zero, it feels like it is blocked.

errors, boiler, fundal, victoria

You can only start it with a tap tap. Support pressure. Check radiators for air availability.

By malfunction of the boiler Victoria Fundal 24. Recently, such malfunctions have appeared. When you try to ignite, it begins to click, both LEDs constantly blink one or another color, it lasts for about 5 minutes, then it still turns on and it can work indefinitely, then the red LED turns off and lights up and lights up and lights up. I drop an error, start, again clicks and LEDs burn for five minutes and it works fine again. 4 years ago I changed a fee, six months ago. traction sensor, in all in operation for about 7 years, the stabilizer is worth.

Fondital Victoria boiler malfunctions

Could you explain why the double.circuit boiler Fundal Victoria cannot turn on? What is the reason?

The long period of ignition of the burning device shows that the flame sensor was clogged. To eliminate the malfunction, it is necessary to clean the sensor and re.enable the device. The traction sensor operates incorrectly. The receipt of the gas mixture into the burning node is suspended. The sensor should be cleaned or changed to a new.

Tell me, please, what is the cause of the malfunction if the gas boiler does not heat the coolant? What is the problem? We use the device exactly six months.

Inspect the heating circuit filter. If there is a blockage in the filter, disassemble and clean the filter element. The impeller of the circulation hydraulic pump is damaged. Check the hydraulic pump and install a new one, if necessary. In addition, check the circulation of water in the heating line. The wear of the heating contour reduces the volume of the circulating coolant, due to this, the device will stop the heating process.

Tell us how to fill a gas boiler?

This operation is recommended to be carried out in a certain order. Open valves of air excretions that are installed in radiators, and follow the operation of the crane-outer on the boiler. Slowly open the fifth tap, testing the stability of the operation of all components of the air heating system without exception. Close air cranes on batteries if you see water. After that, closing the sub.file valve and remove the air again using valves on batteries. Run the device and bring the heating to the required temperature in the heating system, then turn off the hydraulic pump and conduct repeated air abstraction.

Someone will be able to explain what a breakdown when the gas boiler Fondital Victoria Compact goes out?

Problem in flame recognition. Lack of gas pressure. Deterioration of gas intake. Incorrect operation of the gas valve. Breakdown of the details of the ignition mechanism or their electrical compounds are violated. In addition to this, an electronics board may be faulty.

Tell us why the boiler often turns off? For what reason it happened? We use the device for no more than six months.

The reasons for the stop are incorrectly selected unit power, reduced gas pressure, problems with the smoke removal channel, interruptions in the electric network, functional automation failure.

Someone can say what kind of problem if pressure falls in a gas boiler? Connecting the boiler performed this year. How can you eliminate?

The presence of air in the main circuit. Auto.airman failed. It is necessary to replace it. The filter element of the heating circuit is polluted. Clean the filter element. There is a leak in the boiler or in the heating pipeline. Damage to the tap of recharge. Problems with the sensor-relay duct. Inspect and replace if necessary. The circulation water pump was out of order. Poor rotation as a result of impending defect.

You can tell you why the Boiler Fundal Victoria Compact turns on and turns off? How to eliminate it? We use the device exactly half a year.

The flame is not recorded by an electronic module: an error in connecting the phase and neutral. Connect the phase and neutral correctly. If there are no improvements, the control of the replacement module. The flame detection electrode cable disconnected or was damaged. Combine or replace the wiring. The pressure of the gas mixture is too weak. Increase it.

I would like to know what is the reason that the boiler is not ignited? Connection of the boiler was carried out this year. What can be done?

Difficult roster. Gas supply malfunction. Gas valve should be installed in an open position. Incorrect gap between electrodes or their curvature. The electrode spark is weak. Presumably, there are problems in the electrical network.

Why, during the inclusion of a gas boiler, some knock can be heard, and soon a gas-regional device is extinguished. The display displays an error indicating overheating. We were advised to change the heat exchanger. How to eliminate the problem?

The suspension in the operation of the apparatus due to overheating of the coolant does not always indicate the suction of the heat exchanger. Strange noises can occur with a significant amount of scale on the walls of the heat exchanger, and if there is a lot of air in the main circuit. Although first it is recommended to make sure that the thermorele, a three-lane valve and a circulation pump work correctly.

Why is the Victoria Funding Clum clicks while increasing temperature? Say, the gas.regional block begins to burn, the temperature begins to increase, then unusual metal knocks occur. But if we loosen the bolts of fastening the frontal casing, then the blower stops. What is the problem?

From time to time, the boiler rattles, cracks and commenses, especially when the main burning node is disconnected. This is observed due to uneven heating of the surfaces of the heat exchanger, because there is a blockage or lime plaque. We prevail you to urgently clean the heat exchanger.

Why does the boiler do not turn off when heated to a given temperature? Heating lasts up to 85 degrees, then a problem occurs. If you reload, the cycle begins again.

We assume that the control board is damaged, the temperature sensor requires replacement, the sensor has broken to overheat. It is possible that there was an automatic error.

Explain how in the Fondital Victoria Compact boiler reduce pressure? And is it allowed to reduce gas pressure? There is a regulator in the unit that levels the pressure of the gas mixture or they do not need to perform this setting?

The regulator must establish the pressure of the gas entering the unit. If it is quite reduced, the burner does not begin to flare up, when increased, then the fire is likely to be separated from the wick, and the burning device will begin to wander shortly after ignition. Further procedures when adjusting. To sufficiently heat the device. Open the smoke removal channel. Turn on the main burner to the maximum position, during this torch it looks like yellow-blue. By closing the tap of the gas of the received, we eliminate the fire of the yellow shade. Then test the work of the boiler unit in all kinds of modes.

Water leaks from the tap at the bottom of the boiler all the time. The unit itself does not work. What do we have to do?

Apparently, there is a discharge of the coolant from the protective valve. This feature indicates increased pressure in the system. It may also be open a valle of filling the system or it is recommended to pump up an expansion tank.

Fondital Tahiti boilers malfunctions

You can tell me what kind of malfunction if the flame in the Fondital Tahiti Dual CTFS boiler is fading away during the ignition of the flame? Device in work for about a year. What is the problem?

The electronic unit does not fix the flame. The pressure of the gas mixture decreased or the gas mixture is not supplied. Malfunctioning.

I would like to know what problem is when the gas boiler turned off? What kind of breakdown is this? The unit was introduced into the work six months ago.

Lack of gas. Check the inflow of gas into the boiler. The fire.looking electrode is damaged. Inspect the connection of the wires of the electrode and the correct installation. In addition to this, you should clean the electrode from dirt. Gas valve. It will be necessary to replace it. Small power of ignition. Put the set power.

I can’t understand what problem is when the boiler does not warm the hot water? Someone watched such a problem? Connecting the unit was made that year.

Control whether the pipeline lines are connected correctly to household and hot water. Damage of a three.way crane or duct sensor. Test the voltage supplied to the 3rd hopper valve. If there is no electric power, replace the control unit. With standard voltage, 3 should change the 3rd chassis. After the hot water supply temperature sensor is checked. If the sensor is damaged, you need to put a new.

Котел Fondital Ctn24 не работает ГВС

Please tell me what the cause of the damage is if the pressure in the dual.circuit boiler is growing Tachiti Dual Fundal? What does it mean?

Closed or insufficiently open distribution valves. If the pressure on the incoming pipe increases, then the device is blocked. To lower the pressure, it is necessary to open the taps to the full and check if the locking valves leaks. The filter-gryazevik is clogged. Clean the filter or replace it. Along with this, a leakage of the sub.time can be observed due to the uncontrolled rise in pressure. In this case, the tap tap must be changed.

Explain how to drain water from a double.circuit boiler?

Before draining the coolant from the boiler, you need to turn off the power supply. The influx of gas should be stopped. Controversial cranes installed in the heating and cold water supply system must be blocked. Open the water tap of hot water at the site of the water clearance for draining household water from the unit and the pipeline of the hot water. Crush the shut.off valve tap. Unscrew the drain plug placed at the bottom of the boiler and drain the water.

Could you tell me why the boiler is clapping or the boiler? What can be the problem? Launched the device eight months ago.

The cause of cotton is invariably an excessive amount of gas at the time of ignition. When the power of the ignition is correctly adjusted, the gas will accumulate slightly next to the holes of the burner block. With normal thrust, if there is no rod, the gas goes through the chimney. With a slight rod, the gas outflow is not carried out, its ignition is followed, which causes cotton.

Someone can say how to increase the pressure in the Fondital Tahiti Dual? What do we have to do? The device has been operated since last year.

Lowering the pressure of the coolant in the gas boiler to the minimum mark indicates obvious malfunctions inside the system. When the pressure is less than 1 atm, you need to add water using the tap tap. If even after that the gas boiler also does not hold pressure, the system is diagnosed in order to detect fluid leaks.

Maybe someone will explain what kind of problem if the gas boiler is heavily heated? What happened? I mounted the device six months ago.

Problems with fluid circulation in the main circuit. The filter was polluted or the shut.off valve was closed. The overheating sensor is faulty. The heating water heater burned out. The appearance of mechanical contaminants inside the heat exchanger.

I don’t understand why the boiler did not turn on? What is it connected with? The unit has been used for about a year.

Gas does not receive. Check for the correctness of the work of the cut.off and safety valves of gas. The gas valve is disconnected. Connect correctly. Gas valve malfunction. Change it. The burner does not work, there is no spark. Flame recognition electrode breakdown. The electrode must be changed. Control does not allow ignition. Diagnose the board, then change or repair.

The gas boiler Tachiti Dual funds for almost all week regularly gives an error for the removal of smoke, subsequently turning off. What is the malfunction?

Frequent stops of the unit with this error signal the problems in the chimney pipe. In addition, the error is taken into account by the sensor at low speed of the fan. You need to remove the fan and clean its blades. Further, the smoke removal channel should be examined. Perhaps there is pollution. In some cases, the cause of the problem may become a plate heat exchanger contaminated from the outside with a coating of a hood. Clean the heat exchanger plate.

The device thoroughly buzzes and heats up, while the check valve flows. What a failure in work?

If you have no doubt that the boiler unit was installed according to the instructions, first of all, it is necessary to inspect the explosor tank. A situation is possible in which it is better to rearrange it in another place. In addition, the aggregate directly regulates. Suppose to inspect the water duct or establish a gas valve, since its unimportant adjustment turns out to be source of such deteriorations.

I have an attached boiler Fondital Tahiti in a private house. After a few months of trouble.free work, the pressure in it began to weaken. EXPENZOMATE BUSE was emptied, then it pumped it up and poured liquid. Operations were carried out in compliance with the instructions, but literally after a short period, the pressure is again lowered. The leak in the system is not detected. Supposed to establish a new nipple, but it does not work. What kind of damage if the device does not maintain stable pressure? How is the check and adjustment on the tank-expiring?

The coolant is not necessary to remove from the heating system. Turn off the boiler unit. After that, the nipple is removed, which is located on top of the expansion tank. In the case of water release, it is advisable to replace the expansomate tank. Когда начинает выходить небольшой объём воздуха, закрываем кран подпитки и открываем сливной кран, посредством которого сливают вода из прибора. When the water ends to flow out, a pump with a pressure gauge is connected to the nipple, and the pressure indicated in the instructions is pumped. The operation is two to three times, since when pumping, a small part of the liquid often spills, due to which the pressure subsides. It is required to pump up, until the weakening of the pressure and fluid flow will stop. After wrap the cap, turn on the taps and fill the system with the coolant. Run the device and when using the air output valve, lower the excess air from the system.

Fondital boilers errors

Board Fundal does not go to the roser. There is no gas fuel to the gas.regional unit. Wround valve on the supply gas pipeline is blocked. Open the camshaft. Remove the air from the pipeline if the first launch of the device is carried out. Measure the pressure of the gas supplied to the gas knot. The recommended pressure parameters are indicated in the boiler passport. In addition, it is recommended to establish gas pressure on the nozzle (the largest / smallest). Functional gas valve failure. The gas valve must be changed to a new one if its malfunctions are detected. Improper functioning of the electrode of ignition or its breakdown. Check and adjust the gap between the flame control electrode and the burning node. If too much soot is found on the ionization electrode, clean it. Problems of gas equipment components, for example, rupture or closing in the contacts of the gas valve coils. If such problems are present, change the gas valve. Could stick a gas valve. In front of the valve has a fitting. Fasten the silicone pipe on it and lower the excess pressure. Fondital boiler ignition power is insufficient. Enter the boiler service menu and adjust the necessary power. The control fee has burned out or its work was failing. If the transformer of the ignition could not work, it is necessary to restart the unit. When repeating the E1 error, repair or replace the automation unit. After that, check the grounding. The presence of voltage on the cladding is not allowed. Blocking the device can periodically occur due to high humidity. The electrode of ionization, the combustion chamber and the gas.regulatory mechanism should be cleaned thoroughly from condensate. The ionization electrode has a defect. There is no flame on a gas.regional device, although it is fixed by an electronic module. There was a violation in the connections or the closing of the wires from the electrode of ionization to the control module. Test electrical compounds and eliminate problems.

Reduction in the pressure in the system. Gas boiler The Funding Clum displays the E4 error code when a small amount of water in the heating system. The compounds from the control module to the differential pressure relay were violated. A defect in the press start. Initially, look at what indications are fixed on the pressure gauge. If the pressure is weakened, feed the heating system with water. For this procedure, the unit is equipped with a sub.time crane. In cases of repeating E4 error, the system should be examined in order to identify a potential leakage. Leaks can be present in the circulation pump, a fluid discharge valve, in the primary heat exchanger, and in addition, in deformed gaskets and seals.

Overheating of the gas boiler Fondital. The protective thermallane began to heat up to a temperature of 103 degrees. Error code E2 is not displayed when there is no request for ignition in the current period. Когда повышается температура в отопительном контуре, газогорелочное устройство тухнет, хотя теплообменник не прекращает нагреваться. With an increase in the temperature of the protection sensor from overheating to 103 degrees, after 20 seconds. The functioning of the unit will be suspended due to the operation of the electronics system. If the temperature sensor is found above 100 C in the heating cycle, the electronics will wait for a probable temperature reduction of about 25 seconds. If a decrease in the temperature of the sensors of the thermostat and NTC heating for the established segment does not occur, the boiler funds show the error code E2. Bloking when igniting the burner. If the temperature of the safety thermostat in the phase when the flame is formed, more than 103 s, the automation system gives out a problem with a 10 second break. Turning on the safety thermorel of overheating or a heat sensor for heating stopping the device. If the fluid temperature rises to 103C, the sensor is turned on by overheating. After cooling the unit, make it rebooted using the reset button. The temperature sensor for overheating works incorrectly or damaged. It is recommended to change it. In the main circuit, water circulation is insignificant. If, in the process of checking the pressure of an non.heated heating circuit, it is clear that it is reduced, fill the device with a heat capacity. There is an excess of air in the pipeline heating line. Use a car carrier to eliminate air from pipelines. Circulation of circulation. For uninterrupted circulation of the heat resistor, it is necessary to fully open the distribution valves on pipelines. The circulation pump works with interruptions. Too low speed of the pump. There is no required voltage in the electric network. With repeated problems with electricity, connect the device to the network using a stabilizer. The circulation pump motor is damaged or there is an inter.flip socks of the stator winding. Limited pressure, however, the operation of the circulation pump is carried out normally. Probably damaged the impeller, and therefore should be replaced by a hydraulic pump. The fluid to the pump is supplied without delay, but its rotation is not performed. The hydraulic pump should be checked for the likely skew of the rotor shaft. The plug is dismantled, then manually scroll the engine rotor shaft. There is no signal from the control module for the circulation pump, which indicates a failure in the operation of the electronics module. If at the end of the dumping of the device this malfunction has not passed, change the control board. The relay control of the temperature of the exhaust gases is overheated. Reload the device when the cooled relay of the thermostat.

There is no traction. The Fondital gas boiler works correctly and stable when there is good thrust in the smoke removal channel. Automation ensures that smoke removal products do not get into residential premises, and in case of detection of failures in operation, the traction sensor suspenses the functioning of the apparatus with the E3 error code. The main factors due to which the craving becomes unsatisfactory or it is not at all. The smoke channel is very narrowed or inaccuracy when mounting it. There is contamination or ice from the inside on the walls. Excess of the permissible length of the smoke channel. Check out the relevant requirements and norms set forth in the instructions for the operation. The traction sensor broke. You need to check it and replace it if necessary. Contacts from the control board to the pneumorelele of traction are torn. Make testing of electrical contacts and eliminate problems. Moisture is present, and at the same time, the pipe is incorrectly connected to the press. Remove condensate and properly attach the tubes to the press stratum. Fan breakdown. Fan impeller is clogged. Reducing the fan speed due to insufficient lubrication of the drive shaft. Contacts from the control unit to the fan were damaged.

Search for faults and malfunctions in Fondital Tahiti gas boilers

Tachiti Board Board does not start. When to hold the inclusion key, the burner is lit. If you squeeze the button, the device begins to wander. What is the cause of the breakdown?

Probably failed a thermocouple or problems with a gas valve. There may also be a decrease in gas pressure on the input pipes. Sometimes there is too small voltage of the electronic board.

The problem was discovered. The launch is difficult. The lighter burns, but there is no fire on the main burning node. Please tell me what’s the reason?

Most likely, damage to the details of the ignition device. You will need to carry out service for the device and cleaning the inciting device.

Why the gas boiler Fondital Tahiti Dual CTFS 24 stopped turning off at the time when heating reaches the necessary temperature? It heats up to 90C, then falls into the failure. After the restart, it all starts again.

Apparently, the board is damaged, the temperature sensor has a malfunction, the sensor is broken for overheating. It is possible that the automation functions have arisen.

I would like to know why the heating temperature cannot rise above 70C? We need to install more, but on the screen it is displayed that this is the maximum parameter. How to add heating?

If the unit cannot implement a cycle of increasing temperature in the heating system, then the following factors are possible. The set adjustments set a limit of the highest heating temperature up to 70 s. There was a decrease in traction in the chimney channel.

The wall.mounted boiler Fundal Tahiti Dual unsatisfactorily performs the functions in the process of heating the contour of the hot water. From the tap in the kitchen, it flows alternately either cold water or hot. Help, please, why this is happening?

Below the boiler is a crane, from where the water constantly leaks. The device itself does not work. What to do?

Perhaps there is a drop in the coolant through a protective valve. This situation shows that the pressure in the system is increased. In addition, the valve of the system is not closed or it is necessary to pump up the expander tank.

I would like to know what the problem is, if the pressure increase is abruptly, and at the same time, a discharge valve triggers? The screen displays a symbol of heating in the boiler heating mode. What happened?

There is a breakdown of the temperature sensor of the heating line. Lack of necessary circulation in the heating line.

What is the problem if the Tahiti Dual Line CTFS 24 gas boiler constantly starts to turn off? Recently Pierzzhig did not work in any way. The unit service was carried out two weeks ago. What a malfunction?

It seems that there were malfunctions in the smoke exhaust system. You must inspect the chimney. Failure to fulfill the functions of electrical adjustment will mean damage to any part after voltage jumps or water leaks.

Someone can say how to solve the problem with a chimney? Soon the second day, as the return traction is present, while smoke falls immediately into the kitchen. The chimney was made by me on my own. It looks like a metal pipe. Perhaps an error is made in the calculations.

The boiler perfectly produces hot water, but at the time of heating starts, the water quickly boils, and the unit goes into an accident. What could be faulty, and how to get rid of this?

Presumably, the circulation pump is faulty, the electronic board was out of order, breakdown of a thermal attew. At the same time, the filter mesh might be clogged.

At the stage of hot water supply, the device began to produce either cold or hot water alternately. It is not clear what it comes from. How to establish water heating?

Most likely, there is dirt in the heating system or you need to clean the heat exchanger. In addition, a breakdown of the pressure control sensor is possible or the circulation pump broke down.

An important reason is an incorrectly performed configuration of the chimney channel. Sometimes there are soot pollution, which greatly reduces its performance. It is also advisable to control the hood in residential premises.

We operate the boiler Fundal Tahiti 24. He sharply raises the temperature above 96 degrees, but then stops working on overheating. Later, when he cools down, begins to start on his own. What is it connected with?

Overheating stop indicates a lack of circulation in the system. Initially, it is necessary to pay attention to the taps of heating radiators. They are installed in the “open” position. Then a check for pollution of the filter element is made, and you should also make sure that the heat exchanger is clogged.

Installed this unit in the fall of that year. About a month and a half after a month and a half, the device suddenly began to make a lot of noise. Could you tell me why it is noisy?

Most likely, there is a scale in the heat exchanger. If the water is hard, then over time, lime is laid on the walls of the radiator pipes.

I decided to put the boiler Tahiti Dual for heating the house. Tell me how to correctly introduce such an unit into operation?

To properly put into operation this equipment, certain procedures must be performed. Connect the power supply of the device. We put the gas tap open open. Then we turn on the main burner. After adjust the right one.

errors, boiler, fundal, victoria

I need to make repairs. Advise how best to drain the coolant from the unit?

In accordance with the instructions, this operation is carried out so. Disconnect the device from power supply. Overlaid the gas valve. We open the air system. Turn the drain valve. After that, collect the spilled liquid. If necessary, you can drain water using a protective valve. Such a component is placed in the lower part of the device.

You can tell how to diagnose the work of a three.way valve? I think this part does not open until the end. In heating mode, distant batteries cannot pump, and on hot water supply the pipe is heated to supply the coolant under the boiler unit.

Of course, you should look at the 3x-lane valve at the presence of its stem sticking in an intermediate position. We also recommend checking the heating system itself.

We have a Fondital Tahiti gas boiler in our apartment. Until that time he worked well. Currently, 5 seconds after the start, it goes out.