Boile Boile’s mistakes. why arise and how to eliminate
The operation of Beretta boilers is carried out in automatic mode that does not require constant participation of a person. The user is required only to adjust the heating mode by his own sensations, the transfer of the boiler into a winter or summer mode (disconnecting or starting the heating circuit), maintaining the cleanliness of the case and periodic maintenance (service employees).
All serious problems are solved only by the challenge of the master. the elimination of constantly arising errors or incomprehensible phenomena occurring with the boiler in working mode.
In addition, the user independently fills out the system with water (or feeding if necessary).
The process consists in feeding the liquid through the fuel tap and filling the system until the water pressure reaches 1-1.5 bar. This is below the working pressure, but when heated, the water will expand and due to an increase in volume, the pressure reaches the desired value.
The boiler starts automatically when installing the required temperature of the coolant in the system.
It is forbidden to pour water into a hot boiler due to the danger of the destruction of the heat exchanger. You need to wait for the cooler of the boiler, and only after that pour water.
Beretta Ciao 24 Cai
This device is designed for attaching to the wall, it has two circuits for heating. the heating contours and hot water supply, while the burning chamber of open type. What are the main advantages of this equipment? We indicate the following list.
- There is an informing display.
- Power can be adjusted smoothly.
- Automatic adjustment of the temperature regime of the coolant.
- The circulation pump has three speeds and is protected from failures.
- The ability to reconfigure equipment to liquefied gas.
- The thickness of the wall of the heat exchanger is increased on the latest models.
- The installation has an ionization type flame control.
- Water pressure controls the hydraulic press station.
- There is also a smoke removal control.
In order to understand how this unit works, we give a brief instructions for this double.circuit gas boiler of a wall type of beretta.
- The operating modes are displayed by special icons on the indicator panel of the unit.
- To activate the operation of the equipment, it is necessary to enable power, open a gas crane. set up a room temperature regulator and set the Winter or Summer mode according to the situation.
- The disconnection is made with a special button “Turning off”.
The described device has some relative disadvantages. We list them below:
We figured out this model, and now we will study another model.
Wall Beretta City 24 CSI
This equipment also provides for mounting on the wall. There are also two contours, but the chamber for combustion is closed, respectively, the removal of smoke is forced. Power 24 kW, and the area of heated room can reach 240 m2.
The main best qualities of equipment in the list below.
- copper primary heat exchanger;
- protection against freezing and overheating;
- automatic diagnosis of equipment errors;
- The heating temperature of the coolant is adjusted automatically;
- power is adjusted smoothly;
- freezing protection and blocking the pump.
As you can see, in this model, the function is similar in the previous model. Now we will briefly bring the instruction manual for the described gas boiler of Beretta.
- The indicator panel also uses icons, conditional images are deciphered in a technical passport.
- It is possible to connect the remote control.
- Installation rules are described in detail on the pages of a technical passport.
- The passport indicates the connection diagram to the horizontal coaxial chimney, which must be purchased separately.
- To start the equipment, fill out the system with water, turn on the power, open the gas valve, set the regulator to room temperature. Turn on the mode “Winter” or “Summer”.
- The equipment is turned off is carried out by the shutdown button.
In error codes are also indicated. That is, these are encrypted malfunctions that can show Beretta’s dual.circuit gas boiler on the indicator panel. However, we will talk about them now in more detail.
Comparison and problems
To summarize some result, we made a consolidated table for two described models. The result is this: the boilers are approximately similar, and which and the other are very attractive to the consumer. This is this table:
The given table includes information about the faults of a particular gas boiler of Beretta among consumers. Let us sign what you can try to do with certain problems with your own hands.
- Among the malfunctions of the Beretta gas boiler, breakdowns can be found in which the unit does not turn on. Most likely, the reason is either in the absence of water or in the absence of power supply. The worst alignment is a breakdown of the system board. Only the service service will help here.
- Blocking is possible due to excess pressure of the chimney, but this can happen due to a strong street wind.
- Classification of sensors, automation must determine the.
- The equipment may not turn on also due to condensate in the chimney, the latter must be checked, among other things, if the unit does not turn on.
- There are cases of equipment failure due to hoarfront at the output of the chimney. The sensor is triggered, as a result, the equipment does not work.
Here are the main problems that can be encountered during the operation of the described boiler equipment.
You have long come across problems of central heating or hot water supply? These issues can be solved by installing a gas boiler.
The main malfunctions of the Beretta gas boilers
The design of Beretta boilers is a reliable and strong engineering solution, taking into account all the loads and impacts on the parts and units of the unit.
The most likely malfunctions arise in the most critical nodes experiencing maximum temperature or dynamic loads.
According to experts, the number of the most common malfunctions includes:
- Lack of flame on a burner causing a boiler operation blocking. This problem is most often found, since it can be caused by various reasons, from clogging of the nozzles of the burner to the cessation of gas supply in the highway.
- Refusal of management fees-partition of parts or failure due to condensation. This is one of the most unpleasant problems for the user, since replacing management fees is a very expensive procedure.
- Disconnecting the boiler due to exceeding the permissible pressure of smoke gases. Here the reasons can be either clogging of soot or the appearance of ice at the exit of the chimney, and an increase in wind, creating excessive pressure in the chimney.
- The failure of any self.diagnosis sensor. The boiler control system perceives such situations as the emergence of an equivalent error and immediately takes appropriate measures.
- Low water pressure in the supply pipeline of the heating circuit. If the feeding does not help solve the problem, then a leak or failure of the expansion tank is possible.
IMPORTANT! The listed problems relate to the most common, but this does not indicate their obligation. any chance is possible during operation, and the described situations may not appear at all.
Common breakdown of Beretta boilers
According to gas workers involved in the repair and adjustment of Beretta gas boilers, several basic malfunctions that occur most often in the equipment of this brand:
Statistics collected by experts do not mean that in each boiler of the Beretta brand, just such problems will occur.
Perhaps problems will not appear at all for a long period, or completely different malfunctions will occur for other reasons. Each problem or failure in Beretta gas boilers has its own code designation, which is displayed by the control system on the LCD display.
It is necessary to pay attention to malfunctions and problems during the operation of the Beretta gas boiler and eliminate them in a timely manner in order to avoid more serious breakdowns
The identification of malfunctions is due to the system of self.diagnosis, which makes it possible to instantly determine the problems in their occurrence and take appropriate measures.
Boiler “Beretta”: Installation Instructions
The installation should be engaged in a qualified specialist who studied the principle of operation of the Beretta coolant and the corresponding SNiP installations. Regarding the location, the instruction indicates that the installation of configuration C12, C22, C32, C42, C52 and C82 is possible.
To correctly install the boiler, you need to remember the following:
- It is forbidden to put it above the stove or other heating device in a living room.
- Fighting substances cannot be stored near the heating system.
- It is forbidden to attach the unit to the wooden wall without appropriate thermal insulation.
The minimum distance from the wall is 200 millimeters from all sides for subsequent maintenance of the heat exchanger. The mount should be carried out using a bracket. After fixing according to the standards, you can start an electrical connection and connection of gas. For the first procedure, you need to provide access to a variable current with a voltage of 220-230 V. Gas connection must be performed using a stiff eyeliner with a diameter of at least 3/4. Prior to the connection of the gas, it is required to put a shut.off valve, a filter on a gas pipeline if there are extraneous particles in it. At the end of the installation, you need to check the tightness of all the connections provided for by the current installation standards.
Attention! During installation, it is important to take into account the moment of removing of combustion products with air fence, namely the installation of general ventilation. The heating unit must be connected to a smoke exhaust or air duct bred out. This is the only way to ensure safe work with a closed combustion chamber. It is worth noting that this applies to additional equipment and it does not go to the kit for the boiler. It needs to be ordered separately.
Error A01 Boile Beretta
In the beret boilers, the A01 error (or A01 in Russian) indicates the problems of the ignition system (lack of flame, malfunction in the control board). This may be the result of the following reasons:
- one. The flame detection electrode is polluted. You can clean the electrode of the incapacitated soot on your own.
- 2. Lack of gas supply. Violation of the supply in the main gas pipeline or simply closed gas crane (open).
- 3. Violation in the operation of the gas valve. Only a qualified specialist can adjust the valve operation of the valve
- four. The reliability of connecting contacts on the ignition unit is impaired. Corrected independently. Disconnect, clean, connect.
- 5. The failure of the relay included in the system of control of the functioning of the ignition unit, gas valve, fan. This problem is eliminated exclusively by a specialist. The reason can be both in the relay itself and in the electronic board.
Error A02 Boile Beretta
If the beret’s boiler displays error A02 (A03), then in this case, problems with the temperature violation. Usually occurs in the case of a sharp drop in pressure in the system of circulation of the coolant. The reasons may be as follows:
- one. Falf in the circulation pump. The operation of the pump may be disturbed due to contamination. After several inclusions, he can earn in normal mode. It is not recommended to disassemble it yourself. The specialist should do this. Only he will determine the cause of the malfunction and will repair the pump or replace it.
- 2. A malfunction of the temperature sensor. This malfunction is eliminated only by replacing the part.
- 3. Violation of the integrity of electrical connections by the sensor. It is necessary to check the integrity of the insulation of the wiring and check the reliability of the contacts.
Error A03 Boile Beretta
On the bereta boiler display A03 error, problems with removing combustion products. This may be related to:
- one. Clogging the combustion channel of combustion products. This situation rarely arises, there is practically no gas burning residues. But the reason may be the appearance of ice at the output of the pipeline system due to freezing condensate. A strong wind can also cause difficulty in the removal of combustion products, which entails a thermostat operation, disconnecting and blocking the boiler.
- 2. Lack of air supply, in case of compulsory smoke removal. The main malfunction is a fan breakdown. You will need a replacement.
Error A04 Boile Beretta
On the Beretta boiler display, error A04 signals the absence of optimal pressure in the heat exchange system. Error is similar to the error a02. The only difference is that this code indicates primarily the problems within the system of the boiler itself. The appearance on the display of such an error may be as follows:
- one. Clogging the contour of the heat exchanger inside the boiler. Long.term operation using rigid water leads to the formation of scale on the internal surfaces of the heat exchanger. The addition of chemicals to the circulation system of heat supply helps to remove it.
- 2. The manifested leak. Sometimes the master will be able to repair the heat exchanger on the spot (patch up). Otherwise, you have to replace.
- 3. Violation of the tightness of the contour of the heat supply system. Such problems can be eliminated independently using the tool and sealing material.
- four. Malfunction in the operation of the circulation pump. The pump replacement is required.
- 5. Poor wiring contact with pressure sensor. It is eliminated independently (clean and connect).
- 6. Damage to the pressure sensor. You will need a replacement.
The instructions attached to all models of Beretta boilers indicate most beret boilers’ mistakes with a description of possible problem situations arising during operation. In addition, the display displays the working parameters of the boilers. For example, comparing the code of the Bereta City boiler error and the parameters of working functions, the master is able to determine the problem block, node on the spot or eliminate the cause that does not require complex repair work. Qualified masters should deal with problems related to described errors. Only a master who has practical experience in servicing gas boilers of various brands and models can comprehensively diagnose and determine the specific reason for the appearance of errors on the display.
Настенные газовые котлы Beretta
Repair of the boiler Navien | Baxi boilers errors |
Installation of the heating system in the house | Errors of gas boilers |
Gas boilers with installation | Replacing heating radiators |
Turning to us, you agree with the terms of the “user agreement”. the contract of the Offer!
Error A01 Boile Beretta
In the beret boilers, the A01 error (or A01 in Russian) indicates the problems of the ignition system (lack of flame, malfunction in the control board). This may be the result of the following reasons:
- one. The flame detection electrode is polluted. You can clean the electrode of the incapacitated soot on your own.
- 2. Lack of gas supply. Violation of the supply in the main gas pipeline or simply closed gas crane (open).
- 3. Violation in the operation of the gas valve. Only a qualified specialist can adjust the valve operation of the valve
- four. The reliability of connecting contacts on the ignition unit is impaired. Corrected independently. Disconnect, clean, connect.
- 5. The failure of the relay included in the system of control of the functioning of the ignition unit, gas valve, fan. This problem is eliminated exclusively by a specialist. The reason can be both in the relay itself and in the electronic board.
Error A02 Boile Beretta
If the beret’s boiler displays error A02 (A03), then in this case, problems with the temperature violation. Usually occurs in the case of a sharp drop in pressure in the system of circulation of the coolant. The reasons may be as follows:
- one. Falf in the circulation pump. The operation of the pump may be disturbed due to contamination. After several inclusions, he can earn in normal mode. It is not recommended to disassemble it yourself. The specialist should do this. Only he will determine the cause of the malfunction and will repair the pump or replace it.
- 2. A malfunction of the temperature sensor. This malfunction is eliminated only by replacing the part.
- 3. Violation of the integrity of electrical connections by the sensor. It is necessary to check the integrity of the insulation of the wiring and check the reliability of the contacts.
Error A03 Boile Beretta
On the bereta boiler display A03 error, problems with removing combustion products. This may be related to:
- one. Clogging the combustion channel of combustion products. This situation rarely arises, there is practically no gas burning residues. But the reason may be the appearance of ice at the output of the pipeline system due to freezing condensate. A strong wind can also cause difficulty in the removal of combustion products, which entails a thermostat operation, disconnecting and blocking the boiler.
- 2. Lack of air supply, in case of compulsory smoke removal. The main malfunction is a fan breakdown. You will need a replacement.
Error A04 Boile Beretta
On the Beretta boiler display, error A04 signals the absence of optimal pressure in the heat exchange system. Error is similar to the error a02. The only difference is that this code indicates primarily the problems within the system of the boiler itself. The appearance on the display of such an error may be as follows:
- one. Clogging the contour of the heat exchanger inside the boiler. Long.term operation using rigid water leads to the formation of scale on the internal surfaces of the heat exchanger. The addition of chemicals to the circulation system of heat supply helps to remove it.
- 2. The manifested leak. Sometimes the master will be able to repair the heat exchanger on the spot (patch up). Otherwise, you have to replace.
- 3. Violation of the tightness of the contour of the heat supply system. Such problems can be eliminated independently using the tool and sealing material.
- four. Malfunction in the operation of the circulation pump. The pump replacement is required.
- 5. Poor wiring contact with pressure sensor. It is eliminated independently (clean and connect).
- 6. Damage to the pressure sensor. You will need a replacement.
The instructions attached to all models of Beretta boilers indicate most beret boilers’ mistakes with a description of possible problem situations arising during operation. In addition, the display displays the working parameters of the boilers. For example, comparing the code of the Bereta City boiler error and the parameters of working functions, the master is able to determine the problem block, node on the spot or eliminate the cause that does not require complex repair work. Qualified masters should deal with problems related to described errors. Only a master who has practical experience in servicing gas boilers of various brands and models can comprehensively diagnose and determine the specific reason for the appearance of errors on the display.
Repair of the boiler Navien | Baxi boilers errors |
Installation of the heating system in the house | Errors of gas boilers |
Gas boilers with installation | Replacing heating radiators |
Turning to us, you agree with the terms of the “user agreement”. the contract of the Offer!
User manual
The proper operation of the Beretta gas equipment includes compliance with precautions:
- You can not use the device for other purposes and touch its surface with your wet hands.
- It is categorically impossible to close or less space for ventilation of the boiler, since these holes are a necessary condition for proper operation.
- If there is a smell of gas, it is necessary to turn off all the devices, block the gas supply crane and ventilate the room.
- Before carrying out any cleansing work with the boiler, you need to turn it off from the network.
- It is forbidden to store combustible materials with a place near the boiler and try to repair it yourself.
- You can not stretch and twist the wires that come out of the device, even if the device is disabled.
In addition, the management states that it is forbidden to store the unit in an unheated room at a temperature below zero degrees.
The pump does not work. what to do
If the refusal of the circulation pump is noticed, it is necessary to stop the operation of the system and call the master.
There may be several reasons for the refusal, from non.taxes with power to problems with the mechanical part. The first reason is determined by testing and checking the condition of the pump electric motor.
The second reason can be detected by checking the state of the mobile parts of the pump, the lack of difficulties in rotating or moving parts of the mechanism, breakdowns or wear of the gears and other elements.
The decision on the repair or replacement of the pump is made by the result of the survey of performance and the condition of the unit parts. If the forecast for repair work is favorable, the pump is restored, otherwise a complete replacement is necessary.
Wall models
The following models are especially distinguished among the wall.mounted heating boilers.
City series (City)
The main feature that the wall.mounted boiler of this series possesses is compact dimensions, which allows you to install equipment in small city apartments. The attached instruction contains the following technical characteristics:
- A good selection of power: from 24 to 50 kW, which will allow you to choose the necessary model for an apartment or a country house.
- The series contains both single.circuit models designed for heating the room and double.circuit, capable of heating running water for household needs.
- At the same time, a wall.circuit unit is a wall.circuit unit has two independent heat exchangers, which reduces the cost of replacing one of them in case of a malfunction.
Advice! To reduce gas consumption, the most powerful 50 kilowatt installation has a condensation principle of operation. This feature increases the efficiency and heat transfer, while reducing the total consumption of the energy carrier.
EXCLUSIVE series (exclusive)
This series of Beretta boilers is characterized by its functionality and a comfortable operation process. For rational and economical gas consumption, the instruction advises choosing one of the four modes:
Boilers of this series are produced with a capacity of 24 to 35 kW and have the following features:
- Automatic system, capable of, if necessary, to independently feed the heating system.
- The ability to connect an external sensor, which synchronizes the operating mode of the heating apparatus with a temperature on the street.
- The liquid crystalline screen, which, in addition to current information about the condition of the boiler, is displayed codes of errors in case of malfunction in the operation of the equipment.
Another feature that the wall.mounted cauldron of the exclusive series has is the presence of a fan in the combustion chamber: it regulates the thrust power, depending on the modulation of the flame.
Popular breakdowns and their elimination
The lower the serial number of the error, the more often it occurs during the operation of the Beretta boiler.
Consider the most common errors and possible ways to eliminate them:
- A01. Blocking due to lack of flame. There are several reasons. problems with the supply of gas in the trunk line, the gas supply crane into the boiler is blocked, the nozzles of the burner are very clogged. Find out if there is gas in the line, clean the burner and nozzles.
- A02. Overheating of the heat exchanger indicates a lack of water. Check the operation of the circulation pump and the pressure of the OS, add the liquid to the system.
- A03. High pressure in the chimney indicates blockage of the output of ice, hoarfrost, accumulation of soot. Weather factors are possible. a strong gusty wind.
- A 04. The drop in the pressure of the coolant can be caused by a lack of fluid. Check the system for leaks, if detected. eliminate.
- A05. Problems of the thermoresistor of the DHW line are eliminated by the replacement of the sensor.
- A06. The thermoresistor of the heating circuit, failed, is subject to immediate replacement.
- E33. It is necessary to change the electrodes in a plug of power. Beretta boilers are phase dependent, do not work when the phase wire is incorrectly connected.
- E46. Exceeding the permissible temperature of the coolant indicates the problems in the circulation of the liquid. Check the operating mode of the circulation pump.
- The symbol of the “bell” flashes (bell, p). This is a signal from the chimney pressure sensor indicating an obstacle to the yield of smoke, the formation of ice or hoarfrost at the output of the pipe.
The beretta boiler error reset is carried out by pressing the shutdown button and re-turning on the boiler after 5-6 seconds.
Beretta gas boilers’ errors are the meaning and methods of elimination
The emergence of a self.diagnosis system reports on the appearance of a malfunction in Beretta gas boilers. It has controlling sensors that find problems in various nodes and signal the control module about this. As a result of this, the unit is blocked, and an error code appears on the display. Some of them can be eliminated independently. And if it did not work out, then they call a specialist.
The manufacturer of gas boilers Beretta made sure that the buyer has to choose from. on sale there are floor, wall, as well as condensation units. The following models are popular with consumers: Super exclusive, City, short story, plot.
Beretta’s various gas boilers can be mechanical or electronic with an information display. Condensation models are represented by Green, Exclusive Green, Minute line. They spend fuel more economically and productively.
It happens that during the operation of the unit on the screen there was a code of some kind of malfunction. In this case, you can try to restart the device, and if this did not help, you should read in the instructions about the malfunctions of the Berett gas boiler and their elimination. We will analyze the most common errors. Code A01 speaks of problems in the aboard system of a gas boiler. Perhaps there were problems in the control board or there is no fire. The reasons are usually as follows:
- Flame detection electrical wire is closed. it is corrected by cleaning;
- There is no fuel supply. the supply of gas in the highway is violated or the gas valve is closed;
- malfunctions in the operation of the gas valve. only the master can adjust it;
- The connection of contacts on the ignition unit is violated. the contacts should be cleaned and connected;
- rolled up the ignition block. is corrected by a specialist.
Error A02 shows temperature disturbances. Often appears with a sharp decrease in the pressure of the coolant circulation. The reasons can be:
- Problems with a circulation pump due to blockages-only a specialist will be able to correct the situation;
- The problem with the temperature sensor. you will have to replace the part;
- violation of the supply of wires to the sensor. it is necessary to control the integrity of the wiring and contacts.
Code A03 speaks of problems with smoke removal. Perhaps the reasons are as follows:
- blocking the pipe, icing, strong wind. eliminated by cleaning the chimney;
- insufficient air supply due to a fan breakdown, which performs forced smoke removal-you need to replace the part.
Error A04 on the screen of the Beretta gas boiler indicates the absence of normal pressure in the heating system. This code appears as a result:
- breakdown of the pressure sensor. replacement is required;
- problems in the operation of the pump. you will have to replace the element;
- clogging of the heat exchanger. it is necessary to remove the scale using special tools;
- the flow of leaks in the circuit. repair of the heat exchanger;
- weak contact of the wiring with a pressure sensor. clean the edges and connect.
Code A05 shows the failure of the NTC thermal attemptor. it is necessary to inspect the contacts or replace the broken part.
Не работает газовый котел Beretta. Что делать?
Error A06 indicates a breakdown of the NTC heating terminer. you will need to replace a faulty part.
Code A07 indicates that the opening of the relay has not passed. it is required to diagnose the module.
A11 simulates the presence of flame. you need to contact a specialist.
Error A24 appears with incorrect fan operation.
Adj. you need to configure the power of the gas boiler.
Code E33 means a violation of the phase and neutrals. is eliminated by retaking the boiler.
Error E34 appears with frequent presset key presses. If after 45 minutes the testimony does not disappear, you must contact the master. E35 indicates problems in the pressure relay. It is recommended to check the fluid consumption in heat exchangers as indicated in the instructions.
E37 means a false definition of fire. Check the connection of the smoke removal sensor.
Code E38 indicates the closure of the combustion sensor. In this case, you will have to replace it. E39 indicates the occurrence of the contacts of the sensor contacts. it is necessary to replace the wiring.
E40 means voltage drops. it is required to install a stabilizer.
Error E42 reports a short circuit of the sensor on the feed line, E43. sensory contacts are opened, E44. a short circuit of the return sensor. For the elimination of E42, E43 and E44, the connectors should be diagnosed or the broken element should be replaced.
Code E45. opening the sensor, and E46. thermistor indicates an increase in temperature. To eliminate the malfunction, you should make sure of the correct flow rate of the coolant. The normal indicator is 2 m³ per hour.
Error E48 indicates too high the speed of the fan or high temperature of combustion products. It is necessary to check the water consumption or clean the contour of the deposits.
Migration of the 88ºC indicator means the mode of waiting for the ignition.
If the letter P burns, this means preliminary heating of the hot water. Flashing p. received a request for preliminary heating.
An instruction is attached to each model of beretta units, which clearly indicates possible errors and ways to eliminate them. But in any gas boiler, malfunctions can appear, which are not indicated by codes. These include:
- The smell of gas in the boiler room. immediately turn off the boiler, ventilate the room and call gazmiers;
- smell of smoke. check the quality of the thrust in the chimney and the performance of the coaxial pipe fan;
- The ignition of the burner is late. you should check the gas valve, clean the burner and nozzles from soot, adjust the modulation of flame;
- The unit works, but the radiators do not heat up. release excess air using the crane of Maevsky.
Independently eliminate the malfunctions of the gas boiler of the beretta or wall type of beretta can only according to the described recommendations. In other cases, a specialist of the Beretta service center should be called. It is impossible to disassemble the units of the units yourself. this can subsequently lead to damage to the elements and an increase in the cost of repair.
What indicate indicators?
In some models of Beretta gas boilers, such as Beretta City, the appearance of failures in the operation of units can be judged by signals of red, yellow and green indicators.
Indicators are two or three light diodes located on the central panel, which begin to flash with different intensity when a particular failure appears.
The blinking of a green indicator can mean the following:

- 1 time/3.5 seconds. the equipment is transferred to the standby mode, the fire is extinguished;
- 1 time/0.5 sec-the boiler is stopped due to a breakdown;
- 1 time/0.1 sec. the unit is switched to the auto.regulation system;
- The indicator burns and does not flas it. the boiler works fine, the fire burns.
Beretta City can independently stop due to a breakdown in cases of signal from pressure sensors and smoke removal.
The boiler can suspend the work for 10 minutes, during which the correct parameters should be restored. During this time, the system will automatically conduct scanning. A detailed guide on how to check the readings of the sensors of the Beretta gas boiler should already be laid down in the self.diagnosis system.
The inclusion of the red indicator occurs in the following cases:
- The indicator burns and does not blink. if after suspension the work of the boiler is not established, the unit goes into emergency mode;
- The indicator flashes. the operation of the maximum temperature sensor. Sometimes the error can be eliminated using the operating mode switch.
Simultaneous blinking of red and green diodes occurs in the event of a breakdown of the NTC sensor.
The yellow indicator is ignited and continuously burns when the pre.heating of the coolant in the circuit is turned on.
To eliminate all the above.described non.advantages of Beretta gas boilers, it is strongly recommended to use the services of masters of authorized service centers and organizations with which a contract for servicing gas units and the supply of blue fuel have been concluded.
Independent intervention in the complex design of boilers can lead to an even more serious breakdown, which will result in expensive repairs and long.term stopping of the autonomous heating system.
The main series
City boilers are produced in nine variations with various performance and configuration. It is equipped with one or two heating contours with a maximum power of 24 and 28 kW with combustion chambers of both open and closed type. Natural and liquefied gas are used as fuel. Tound boilers are also produced with heat production of up to 50 kW with one or two contours. The cost of the boiler unit depends on the configuration and power.
Technical characteristics of the City 35 CSI model:
- heating of the room with an area of up to 350 m2;
- heat.exchanging apparatus. separate type; for the heating circuit. copper, for hot water supply. steel;
- combustion chamber. turbocharged type;
- Efficiency. 93%;
- power. 37.6 kW;
- Water heating. 20 liters per minute;
- Weight. 42 kg.
CIAO boilers are produced only with two circuits with both open and closed combustion chambers. The equipment is equipped. A distinctive feature of this series of boilers is the option of protection against freezing of the coolant. In the event that the coolant has cooled up to 5 degrees, automatic water heating in the system begins.
Technical characteristics of the model “CIAO 24 CSI N”:
- heating a room with an area of up to 240 m2;
- fuel consumption. 2.78 cubic meters per hour;
- power 24 kW;
- Efficiency. 92%;
- combustion chamber. closed;
- ignition. automatic;
- Dimensions. 74 x 40 x 34 cm.
Novella series boilers are made with an open combustion chamber, piezo.Zhizhig, and energy.dependent. Produced only in the floor with one contour. They are equipped with a heat exchange device made of cast iron and a two.stage burner of stainless steel. Thermal production of equipment. from 90 to 280 kW.
Technical features of the Novella 45 RAI model:
- combustion chamber. open;
- performance. 45 kW;
- fuel. natural gas;
- fuel consumption. 5 cubic meters per hour;
- Weight. 154 kg.
Boiler boilers with a heat production of 28 kW are equipped with closed or open.type combustion chambers. A distinctive feature of the boilers of this series is the presence of a built.in boiler with a volume of 60 liters with a heat exchanger apparatus. In the configuration with the boiler there is a circulation pump unit. The equipment is equipped with an option to freeze the coolant and burning device.
Exclusive models are installed in closed heating contours with compulsory circulation of the heat media in the system with four functioning modes. The capacity of the equipment lies in the range of 16. 35 kW.
Technical features of the Exclusive 24 CAI model:
- The number of contours is two;
- heat production. 26.7 kW;
- Efficiency. 90%;
- combustion chamber. open type;
- Dimensions. 33 x 80 x 40 cm.
The Fabula series represents a double.circuit boiler unit with a built.in boiler, which provides a large volume of hot water without interruptions with a heating room. The boiler can be a capacity of 80, 90 and 120 liters. Maximum performance. 43 kW with combustion modulation. The heating circuit is equipped with a heat exchanger apparatus of cast iron, while the hot water supply circuit is made of steel with a magnesium anode, which provides reliable protection against the formation of scale. The advantages of this series include reliability and high quality of the assembly of parts.
Characteristics of the Fabula 31 Cai 80 model:
- power. 31 kW;
- The coefficient of useful action is 90%;
- 80 liter boiler;
- weight. 125 kg;
- Dimensional dimensions. 135 x 45 x 79 cm;
- fuel consumption. 3.5 cubic meters per hour.
Beretta gas boilers errors
Any samples of beret products are characterized by reliability and safety during operation. Nevertheless, an increase in the number of useful functions, the complication of electronic filling, a modification of gas reinforcement and an ordinary human factor serve as the causes of malfunctions and technical failures in the work of equipment.
All boilers are equipped with tracking systems for the normal functioning of nodes and mechanisms. In case of malfunctions of gas boilers beretta, errors in the form of alphanumeric code or light indication (bereta beret boilers) are displayed on a liquid crystal display.
Most of the malfunctions correlate with certain processes of the boiler:
- Violation of circulation or insufficient pressure in the heating system;
- Unsatisfactory traction in the chimney and lack of air for combustion;
- Violation of the optimal temperature regime;
- Malfunctions in the ignition system;
- Software failure or failure of an electronic control unit.
In most cases, when failures occur in the boiler operation, it is blocked. If repeated attempts to launch the boiler do not lead to a positive result, it remains to look for the reasons for the failures of the parameters of the support systems.
The attached instructions describe the causes of most problems, it is explained in detail what to do in such a situation and how to correct a particular problem. The alphanumeric-cyphrax code of the beretta boilers or light indication indicates possible reasons.
Error A01 Boile Beretta
In the beret boilers, the A01 error (or A01 in Russian) indicates the problems of the ignition system (lack of flame, malfunction in the control board). This may be the result of the following reasons:
- one. The flame detection electrode is polluted. You can clean the electrode of the incapacitated soot on your own.
- 2. Lack of gas supply. Violation of the supply in the main gas pipeline or simply closed gas crane (open).
- 3. Violation in the operation of the gas valve. Only a qualified specialist can adjust the valve operation of the valve
- four. The reliability of connecting contacts on the ignition unit is impaired. Corrected independently. Disconnect, clean, connect.
- 5. The failure of the relay included in the system of control of the functioning of the ignition unit, gas valve, fan. This problem is eliminated exclusively by a specialist. The reason can be both in the relay itself and in the electronic board.
Error A02 Boile Beretta
If the beret’s boiler displays error A02 (A03), then in this case, problems with the temperature violation. Usually occurs in the case of a sharp drop in pressure in the system of circulation of the coolant. The reasons may be as follows:
- one. Falf in the circulation pump. The operation of the pump may be disturbed due to contamination. After several inclusions, he can earn in normal mode. It is not recommended to disassemble it yourself. The specialist should do this. Only he will determine the cause of the malfunction and will repair the pump or replace it.
- 2. A malfunction of the temperature sensor. This malfunction is eliminated only by replacing the part.
- 3. Violation of the integrity of electrical connections by the sensor. It is necessary to check the integrity of the insulation of the wiring and check the reliability of the contacts.
Error A03 Boile Beretta
On the bereta boiler display A03 error, problems with removing combustion products. This may be related to:
- one. Clogging the combustion channel of combustion products. This situation rarely arises, there is practically no gas burning residues. But the reason may be the appearance of ice at the output of the pipeline system due to freezing condensate. A strong wind can also cause difficulty in the removal of combustion products, which entails a thermostat operation, disconnecting and blocking the boiler.
- 2. Lack of air supply, in case of compulsory smoke removal. The main malfunction is a fan breakdown. You will need a replacement.
Error A04 Boile Beretta
On the Beretta boiler display, error A04 signals the absence of optimal pressure in the heat exchange system. Error is similar to the error a02. The only difference is that this code indicates primarily the problems within the system of the boiler itself. The appearance on the display of such an error may be as follows:
- one. Clogging the contour of the heat exchanger inside the boiler. Long.term operation using rigid water leads to the formation of scale on the internal surfaces of the heat exchanger. The addition of chemicals to the circulation system of heat supply helps to remove it.
- 2. The manifested leak. Sometimes the master will be able to repair the heat exchanger on the spot (patch up). Otherwise, you have to replace.
- 3. Violation of the tightness of the contour of the heat supply system. Such problems can be eliminated independently using the tool and sealing material.
- four. Malfunction in the operation of the circulation pump. The pump replacement is required.
- 5. Poor wiring contact with pressure sensor. It is eliminated independently (clean and connect).
- 6. Damage to the pressure sensor. You will need a replacement.
The instructions attached to all models of Beretta boilers indicate most beret boilers’ mistakes with a description of possible problem situations arising during operation. In addition, the display displays the working parameters of the boilers.
For example, comparing the code of the Bereta City boiler error and the parameters of working functions, the master is able to determine the problem block, node on the spot or eliminate the cause that does not require complex repair work. Qualified masters should deal with problems related to described errors.
Beretta boilers
To resume the operation of the boiler, transfer the operating mode switch to the position. wait 5-6 seconds, then again transfer it to the right position. After that, the boiler start automatically. Comment. If you cannot resume the normal operation of the boiler, call a service specialist.
Malfunctions
In case of any malfunction in the boiler operation, it will go out on the display. a flashing code will be displayed, and the symbols are reset and/or. The following table describes various malfunctions.
- (D): The malfunction causes the final stop of the boiler
- (T): temporary. In case of this malfunction, the boiler is automatically trying to resume the work.
- (°): only for an external boiler-accumulator with a sensor. The malfunction code is displayed only when the boiler is in standby mode
- : If there was a fault of “insufficient pressure in the heating system”, follow the heating system to add a recharge procedure
Errors on the main board (Master)
- Type A errors that can be turned off only by pressing the Reset button
- Type E errors that disappear after the reason that causes them disappears
Errors that are dumped automatically, type E
The following are errors that disappear automatically. If one of the errors below occurs, the red light indicator lights up.
Errors on a subordinate board (SLAVE)
If an error will occur on a subordinate board (SLAVE), which must be dropped manually, you must press the Reset button on a subordinate boiler.
- 5 unsuccessful ignition attempts
- Make sure the gas valve is open.
- Make sure that a spark is slipping between the two electrodes.
- Replace MSVA (water entering the diagram).
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- Internal software error
- Press the Reset button (reset).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- Fan error
- The measured fan speed changes too quickly compared to the read speed.
- Check the fan.
- Check the electrical connection of the fan.
- Replace the fan.
- Confused phase and neutral
- Correctly connect the phase wires and neutrals.
- Reset button error (Reset)
- The button was pressed more than 7 times for 30 minutes. Wait until the error is lost. If after a maximum of 40 minutes the error is still present, replace the subordinate fee.
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
- Flame detection error
- Clean the electrodes.
- Replace the electrode.
- Frequency is not 50 hertz
- Check the frequency in the power line.
- INTERNAL ERROR
- Replace the subordinate electronic board (SLAVE).
There is no spark when turned on.
Beretta column. products of the Italian Corporation Riello. Beretta gas speakers with various types of combustion chambers are presented on the world market: closed and open, electro- or piezo-roding.
Among the main parts of the presented model of the column with piezo-rod:
- The mechanism of traction control.
- Pipe smoke removal. allows you not to accumulate smoke in the room, sending it to ventilation.
- Heat exchanger. is responsible for heating water in a column.
- Squeezing burner. gas is ignited here.
- Burner. gas combustion occurs here.
- Hydraulic valve. is responsible for the passage through the water column.
- Thermoregulator. temperature controller.
- Gas valve. allows you to open or close the flow of gas into the burner.
- Gas entrance. passes gas into the burner.
- Gas pressure regulator, which provides the opportunity to stabilize the pressure of the gas entering the column with its instability.
- Piezorodzhiga button.
- The economizer, which allows you to choose a certain temperature of water heating, as well as, due to its functions that performs the function of saving gas.
- Gas pressure device and gaskets that are attached to the input of the pressure regulator.
- The electrode of the ignition.
- Thermocouple.
The column is equipped with automatic power regulation depending on the amount of water flowing through it. With an active smell burner, the ignition and the equipment is turned off automatically.
Membrane and gas unit
This is no longer a popular reason why the Oasis gas column does not light up. If there is deformation on the membrane, traces of wear, then the burner will not ignite. The point here is in principle. When water enters the system on the membrane, pressure is carried out. It has an effect on the gas valve. it should open and supply gas to the burner of the column.
If there are problems with the membranes, then experts recommend replacing it with silicone. It is believed that they are more durable.